HP Integrity Superdome SX1000 HP Insight Management WBEM Providers on Integrit
HP Integrity Superdome SX1000 Manual
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity Superdome SX1000 manual content summary:
- HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 1
HP Insight Management WBEM Providers for Windows on Integrity Servers Data Sheet Part number 5992-4515 First Edition September 2008 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP license. Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation. - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 3
Contents 1 Overview...13 2 Base server ...14 2-1 Overview...14 2-2 Use cases ...14 2-3 Class implementations ...14 16 HP_SystemPhysicalProcessor 40 3-3-17 HP_ProcessorLocation ...41 3-3-18 HP_ProcessorElementLocation 42 3-4 Supported indications...42 4 System Power Supply ...43 4-1 Overview...43 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 4
...48 4-3-11 CIM_ConfigurationCapacity 49 4-3-12 CIM_ElementCapacity ...49 4-4 Supported indications...50 5 System fan ...51 5-1 Overview...51 ...56 5-3-11 CIM_ConfigurationCapacity 57 5-3-12 CIM_ElementCapacity ...57 5-4 Supported indications...58 6 System Temperature Sensor ...59 6-1 Overview... - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 5
HP_PCICardInSlot ...88 8-3-6 HP_RealizesPCIDevice ...89 8-3-7 HP_SystemPCISlot ...89 8-3-8 HP_SystemPCIDevice ...89 8-3-9 HP_Location ...89 8-3-10 HP_ElementLocation...90 8-4 Supported indications...90 9 Management Processor Lite...91 9-1 Overview...91 9-2 Use cases ...91 9-3 Class implementations - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 6
110 CIM_ElementSoftwareIdentity 111 CIM_InstalledSoftwareIdentity 111 Supported indications ...112 12 Ethernet Teaming 21 HP_Location ...127 12-3-22 HP_ElementLocation 127 12-3-23 HP_EthEventSettings 128 12-4 Supported indications ...129 13 Smart Array ...157 13-1 Overview ...157 13-2 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 7
13-3-11 13-3-12 13-3-13 13-3-14 13-3-15 13-3-16 13-3-17 13-3-18 13-3-19 13-3-20 13-3-21 13-3-22 13-3-23 13-3-24 13-3-25 13-3-26 13-3-27 13-3-28 13-3-29 13-3-30 13-3-31 13-3-32 13-3-33 13-3-34 13-3-35 13-3-36 13-3-37 13-3-38 13-3-39 13-3-40 13-3-41 13-3-42 13-3-43 13-3-44 13-3-45 13-3-46 13-3-47 13 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 8
(Association 196 HPSA_DiskPhysicalPackageDiskDriveLocation (Association 196 HPSA_SCSIProtocolEndpointSCSIProtocolController (Association 197 HPSA_StorageEnclosureEnclosureLocation (Association 197 Supported indications ...197 14 FC HBA...249 14-1 Overview ...249 14-2 Use - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 9
270 HPFCHBA_SystemPackaging 270 HPFCHBA_ConcreteIdentity 270 HPFCHBA_GroupHostedCollection 271 HPFCHBA_FCPortGroupSystemSpecific 271 HPFCHBA_Location 271 HPFCHBA_PhysicalElementLocation 272 Supported indications ...272 15 SAS HBA...273 15-1 Overview ...273 15-2 Use cases...273 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 10
(Association 304 HPSAS_PhysicalPackageArraySystemLocation (Association 305 HPSAS_DiskPhysicalPackageDiskDriveLocation (Association 305 HPSAS_SCSIProtocolEndpointSCSIProtocolController (Association 305 Supported indications ...305 16 SCSI HBA ...340 16-1 Overview ...340 16-2 Use - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 11
...367 17 System software ...402 17-1 Overview ...402 17-2 Use cases...402 17-3 Class implementations ...402 17-3-1 CIM_SoftwareIdentity ...402 17-3-2 CIM_InstalledSoftwareIdentity 404 17-4 Supported indications ...405 18 Profile registration...406 18-1 Overview ...406 Contents 11 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 12
-3 18-3-1 18-3-2 18-3-3 18-3-4 18-3-5 18-4 Use cases...406 Class implementations ...406 CIM_RegisteredProfile...406 HP_RegisteredProfile...408 HP_ExtendsProfile...409 HP_ReferencedProfile...410 HP_ElementConformsToProfile 410 Supported indications ...410 19 For more information...411 Contents 12 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 13
management data through the Windows® Management Instrumentation (WMI) framework for HP Integrity server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires Windows Server® 2003 or Windows Server 2008, and WMI. 0BOverview 13 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 14
• HPWmiSys.mof 2-2 Use cases For use cases, see the HP Base Server profile (P00105), HP Base Server Physical Asset profile (P00114), DMTF Power State Management Profile (DSP1027), model the base server. Only one instance of HP_WinComputerSystem is instantiated on an Integrity server. The following - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 15
EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName HP_WinComputerSystem Roles Computer system roles string (writable property; persistent across reboots). CIM_ComputerSystem 1BBase server 15 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 16
to not set (writable property; persistent across reboots). SecondaryOwnerPager Computer system secondary owner pager string; initialized to not set (writable property; persistent across reboots). 1BBase server 16 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 17
chassis. Only one instance of HP_ComputerSystemChassis is instantiated on an Integrity server. The following properties are implemented. Table 2-3 Class: 3 (Chassis/Frame) See MOF for definitions. This value is retrieved from SMBIOS. • 0 (Unknown) • 1 (True) • 2 (False) 1BBase server 17 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 18
properties are implemented. Table 2-5 Class: HP_PowerManagementService Properties Property name CIM_ManagedElement Caption Description ElementName Property implementation Server Power Management Service HP Integrity Server Power Management Service Server Power Management Service 1BBase server 18 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 19
Service HP_PowerManagementService 2-3-5 HP_PowerManagementCapabilities HP_PowerManagementCapabilities extends the class CIM_PowerManagementCapabilities to model the server power management capabilities. Only one instance of HP_PowerManagementCapabilities is instantiated on an Integrity server - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 20
[1]: 4 (Power Cycling Supported) • PowerChangeCapabilities[0]: 3 (Power State Settable) • PowerChangeCapabilities[1]: 4 (Power Cycling Supported) • PowerStatesSupported[0]: 0 HP_AssociatedPowerManagementService is instantiated on an Integrity server. The following properties are implemented - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 21
and the HP_PowerManagementService instance. Only one instance of HP_HostedPowerManagementService is instantiated on an Integrity server. The following properties are implemented. Table 2-9 Class: HP_HostedPowerManagementService Property name CIM_Dependency CIM_HostedDependency CIM_HostedService - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 22
of the release date, MM is the two digit month of the release date, and DD is the two digit day of the release date. HP 11 (Bios/FCode) System ROM Firmware HPQ: where is the system ROM family code (for example, HPQ:P31). CIM:SoftwareFamily 1BBase - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 23
CIM_InstalledSoftwareIdentity and associates the HP_ComputerSystem instance and an HP_SystemROMFirmware instance. The following properties are implemented. Table 2-12 Class: HP_SystemROMInstalledFirmwareIdentity Property name CIM_InstalledSoftwareIdentity Property implementation 1BBase server 23 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 24
Property name HP_SystemROMInstalledFirmwareIdentity InstalledSoftware System Property implementation ref: HP_SystemROMFirmware ref: HP_ComputerSystem 2-4 Supported indications There are no indications specific to the base server profile implementation. 1BBase - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 25
• HPWmiProc.dll • HPWmiProcEvt.dll • HPWmiProcEvtMsg.dll 3-2 Use cases For use cases, see HP CPU Profile (P00106), HP CPU Consolidated Status Profile (P00107), HP CPU Physical Asset Profile (P00108), and HP Location Profile (P00124). 3-3 Class implementations The following classes describe the CPU - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 26
By BIOS (POST Error), where a is the slot number and b is the socket number • Processor-module in Slot: a Socket: b disabled by User through BIOS Setup, where a is the slot number and b is the socket number • 0 (Unknown), when OperationalStatus[0]=0 (Unknown) • 5 (OK), when OperationalStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 27
Computer system name from Windows API GetComputerSystemName() HP_Processor Proc n, where n is the processor number • 1 (CPU Enabled) • 2 (CPU Disabled by User using BIOS Setup) • 3 (CPU Disabled By BIOS (POST Error)) • 7 (Other) Processor family number from SMBIOS (for example, 179 for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 28
Table 3-3 Class: HP_ProcessorCapabilities Property name InstanceID ElementName CIM_EnabledLogicalElementCapabilities ElementNameEditSupported RequestedStatesSupported CIM_ProcessorCapabilities NumberOfProcessorCores NumberOfHardwareThreads HP_ProcessorCapabilities Property implementation HPQ: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 29
by BIOS (POST Error), where a is the slot number and b is the socket number • Processor-module in Slot: a Socket: b disabled by User through BIOS Setup, where a is the slot number and b is the socket number • 0 (Unknown), when OperationalStatus[0]=0 (Unknown) • 5 (OK), when OperationalStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 30
Table 3-4 Class: HP_ProcessorCore Property name Characteristics HP_ProcessorCore Bootstrap Property implementation • For x86 processors: Characteristics[0]: 3 (32-bit Capable) • For x64 processors: ○ Characteristics[0]: 3 (32-bit Capable) ○ Characteristics[1]: 2 (64-bit Capable) • False • True - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 31
by BIOS (POST Error), where a is the slot number and b is the socket number • Processor-module in Slot: a Socket: b disabled by User through BIOS Setup, where a is the slot number and b is the socket number • 0 (Unknown), when OperationalStatus[0]=0 (Unknown) • 5 (OK), when OperationalStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 32
number Examples: • Level 1 Data Cache • Level 2 Unified Cache One of the following: • Level x Data Cache, where x is the cache level number • Level x Instruction Cache, where x is the cache level number • Level x Unified Cache, where x is the cache level number Examples: • Level 1 Data Cache • Level - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 33
the socket number • Processor-module in Slot: a Socket: b disabled by User through BIOS Setup, where a is the slot number and b is the processor number, x is the cache level number, and is the cache type (Data, Instruction, or Unified) • Proc p, Core c, Level x Cache, where p is the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 34
Table 3-6 Class: HP_ProcessorcacheMemory Property name NumberOfBlocks Primordial CIM_Memory HP_CacheMemory HP_ProcessorCacheMemory Property implementation Number of blocks in this cache (for example, 8192 or 524288) 0 (False) 3-3-6 HP_SystemProcessor HP_SystemProcessor extends the class - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 35
HP_ProcessorCore ref: HP_HardwareThread 3-3-10 HP_AssociatedCacheMemory HP_AssociatedCacheMemory extends the class CIM_AssociatedCacheMemory. The Integrity implementation class is HP_AssociatedProcessorCacheMemory. HP_AssociatedProcessorCacheMemory associates an HP_Processor or an HP_ProcessorCore - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 36
(Tertiary) • 0 (Unknown) • 1 (Other) • 2 (Write Back) • 3 (Write Through) • 4 (Varies with Address) • 5 (Determination Per I/O) • 0 (Unknown) • 1 (Other) • 2 (Instruction) • 3 (Data) • 4 (Unified) Cache line size in bytes • 0 (Unknown) • 1 (Other) • 2 (Read) • 3 (Read-Ahead) • 4 (Read and Read-Ahead - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 37
3-3-11 HP_ProcessorCollection HP_ProcessorCollection extends the class HP_GroupSystemSpecificCollection. The following properties are implemented. Table 3-12 Class: HP_ProcessorCollection Property name CIM_ManagedElement Description ElementName CIM_Collection CIM_SystemSpecificCollection InstanceID - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 38
Table 3-13 Class: HP_ProcessorGroupHostedCollection Property name CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_ProcessorGroupHostedCollection Antecedent Dependent Property implementation ref: HP_ComputerSystem ref: HP_ProcessorCollection 3-3-13 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 39
by BIOS (POST Error), where a is the slot number and b is the socket number • Processor-module in Slot: a Socket: b disabled by User through BIOS Setup, where a is the slot number and b is the socket number • 0 (Unknown), when OperationalStatus[0]=0 (Unknown) • 5 (OK), when OperationalStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 40
Table 3-15 Class: HP_ProcessorChip Properties Property name Manufacturer Model Version PoweredOn CanBeFRUed CIM_PhysicalComponent RemovalConditions CIM_Chip HP_ProcessorChip ProcessorChipRevision Property implementation Processor manufacturer string from SMBIOS (for example, Intel or AMD) Model y, - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 41
Table 3-17 Class: SystemPhysicalProcessor Property name CIM_Component CIM_Container HP_SystemPhysicalProcessor GroupComponent PartComponent Property implementation ref: HP_ComputerSystemChassis ref: HP_ProcessorChip 3-3-17 HP_ProcessorLocation HP_ProcessorLocation implements the class HP_Location - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 42
Property name CIM_ElementLocation HP_ElementLocation HP_ProcessorElementLocation Element PhysicalLocation Property implementation ref: HP_ProcessorChip ref: HP_ProcessorLocation 3-4 Supported indications There are no indications specific to the CPU profile implementation. 2BCPU 42 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 43
.mof • HPWmiEvtCons.mof • HP_Sensor.mof 4-2 Use cases For user cases, see the HP Power Supply Profile. 4-3 Class implementations Classes and properties are implemented as specified in the following tables for Integrity server platforms where available. The following classes describe power supplies - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 44
describing the type of power supply (see MOF) 4-3-2 HP_PowerCollection HP_PowerCollection is used to model power supply collections on Integrity servers. The Windows implementation class is HP_WinPowerCollection. There is one instance of this class on systems modeling power supplies. 3BSystem - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 45
Table 4-3 Class: HP_PowerCollection Property name CIM_ManagedElement Caption Description ElementName CIM_SystemSpecificCollection InstanceID HP_GroupSystemSpecificCollection GroupOperationalStatus[0] GroupStatusDescriptions[0] Property implementation Power Collection This is a collection of all - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 46
power supply redundancy sets on Integrity servers. The Windows implementation class is redundancy set instance Unique identifier for this power redundancy instance The maximum number of power supplies supported for this redundancy set The minimum number of power supplies needed to function 3 (Load - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 47
Table 4-5 Class: HP_MemberOfPowerRedundancy Property name Collection Member Property implementation References HP_PowerRedundancySet References HP_PowerSupply 4-3-5 HP_HostedPowerRedundancySet HP_HostedPowerRedundancySet is used to represent an association between HP_PowerRedundancySet and the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 48
implementation References HP_ComputerSystem References HP_PowerSupply 4-3-9 HP_Location HP_Location is used to model power supply locations on Integrity servers. The Windows implementation class is HP_WinPowerSupplyLocation. Table 4-10 Class: HP_Location Property name CIM_ManagedElement Caption - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 49
CIM_ManagedElement References CIM_Location 4-3-11 CIM_ConfigurationCapacity CIM_ConfigurationCapacity is used to model power supply configuration capacity on Integrity Servers. The Windows implementation class is HP_WinPowerSupplyConfigurationCapacity. There is one instance of this class on systems - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 50
4-4 Supported indications There are no indications specific to the system power supply profile implementation. 3BSystem Power Supply 50 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 51
the profiles listed to support fans installed in Integrity servers. The following profiles are implemented, and the following files are installed by this provider. Table 5-1 Overview Implemented Profiles Provider Installation Files • HP Fan Profile 1.0 • HP Location Profile 1.0 • HPWmiSensor.dll - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 52
for this fan instance HP_ComputerSystem.CreationClassName HP_ComputerSystem.Name 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) True • True-if fan supports variable speed • False-if fan does not support variable speed or is unknown Enumeration describing the type of fan (see MOF) 4BSystem fan 52 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 53
5-3-2 HP_CoolingCollection HP_CoolingCollection is used to model fan collections on Integrity Servers. The Windows implementation class is HP_WinCoolingCollection. There is one instance of this class on systems modeling fans. Table 5-3 Class: HP_CoolingCollection Property name CIM_ManagedElement - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 54
to model fan redundancy sets on Integrity servers. The Windows implementation class is set instance Unique identifier for this cooling redundancy instance Represents the maximum number of fans supported for this redundancy set Represents the minimum number of fans needed to function 3 (Load - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 55
Table 5-5 Class: HP_MemberOfCoolingRedundancy Property name Collection Member Property implementation References HP_CoolingRedundancySet References HP_Fan 5-3-5 HP_HostedCoolingRedundancySet HP_HostedCoolingRedundancySet is used to represent an association between HP_CoolingRedundancySet and the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 56
Property implementation References HP_ComputerSystem References HP_Fan 5-3-9 HP_Location HP_Location is used to model fan locations on Integrity servers. The Windows implementation class is HP_WinFanLocation. Table 5-10 Class: HP_Location Property name CIM_ManagedElement Caption Description - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 57
Property implementation References CIM_Location 5-3-11 CIM_ConfigurationCapacity CIM_ConfigurationCapacity is used to model fan configuration capacity on Integrity Servers. The Windows implementation class is HP_WinFanConfigurationCapacity. There is one instance of this class on systems - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 58
5-4 Supported indications There are no indications specific to the system fan profile implementation. 4BSystem fan 58 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 59
• HPWmiEvtCons.mof 6-2 Use cases For use cases see the HP Sensor Profile. 6-3 Class implementations The following classes and properties are implemented as specified in the following tables for Integrity server platforms. The following classes describe temperature sensors. 6-3-1 HP_NumericSensor - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 60
Table 6-2 Class: HP_NumericSensor Property name Description ElementName CIM_ManagedSystemElement OperationalStatus[0] StatusDescriptions[0] HealthState Name CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_EnabledLogicalElement EnabledDefault EnabledState - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 61
Table 6-2 Class: HP_NumericSensor Property name SensorType CurrentState PossibleStates CIM_NumericSensor CurrentReading BaseUnits RateUnits UnitModifier SupportedThresholds SettableThresholds UpperThresholdNonCritical UpperThresholdCritical UpperThresholdFatal HP_NumericSensor NumericSensorType - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 62
6-3-2 HP_SensorCollection HP_SensorCollection is used to model temperature sensor collections on Integrity servers. The Windows implementation class is HP_WinSensorCollection. There is one instance of this class on systems modeling sensors. Table 6-3 Class: HP_SensorCollection Property name - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 63
. Table 6-6 Class: HP_SystemSensor Property name GroupComponent PartComponent Property implementation References HP_ComputerSystem References HP_NumericSensor 6-4 Supported indications There are no indications specific to the system temperature sensor profile implementation. 5BSystem Temperature - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 64
.mof • HPErrorMetaInstance.mof • HPWmiEvent.mof • HPWmiEvtCons.mof 7-2 Use cases For use cases, see the HP memory profile. 7-3 Class implementations The following classes are implemented for Integrity server platforms where available. The following classes describe system memory resident on an - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 65
Table 7-2 Class: HP_Memory Property name Description ElementName CIM_ManagedSystemElement OperationalStatus StatusDescriptions HealthState Name CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 66
EndingAddress Volatile HP_Memory HP_WinMemory Property implementation 3 (Read/Write Supported) 1 (byte) Capacity in bytes Capacity in bytes 7-3-3 HP_MemoryModule The class HP_MemoryModule represents a physical memory module on Integrity servers. There is an instance of this class for each possible - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 67
Table 7-4 Class: HP_MemoryModule Property name CIM_ManagedElement Caption CIM_ManagedSystemElement OperationalStatus StatusDescriptions HealthState Name CIM_PhysicalElement CreationClassName Tag Description ElementName Manufacturer PartNumber SerialNumber CIM_PhysicalComponent Property - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 68
Table 7-4 Class: HP_MemoryModule Property name RemovalConditions CIM_Chip CIM_PhysicalMemory DataWidth InterleavePosition Capacity TotalWidth Speed MemoryType PositionInRow FormFactor BankLabel HP_MemoryModule Spd Property implementation 3 (Removable when off) Data width of memory module in bits - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 69
7-3-4 HP_MemoryBoard The class HP_MemoryBoard represents a physical memory board on Integrity Servers. There is an instance of this class for each memory board in the system. Table 7-6 Class: HP_MemoryBoard Property name CIM_ManagedElement Caption CIM_ManagedSystemElement OperationalStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 70
HostingBoard HP_MemoryBoard Locked NumberOfSockets AvailableMemory TotalMemory Property implementation A string describing the physical location of the memory board. On Integrity systems, a memory board instance can be a cell board, a system board or a memory extender board. Removal conditions of - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 71
(Degraded) • 3 (Degraded) error, for example, there is a problem with the board release latch (unlock error) or there is an • Memory The class HP_MemoryRedundancySet represents memory board redundancy on Integrity servers supporting advanced memory protection (AMP). There is one - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 72
Table 7-8 Class: HP_MemoryRedundancySet Property name RedundancyStatus HP_MemoryRedundancySet OperatingSpeed AvailableMemory TotalMemory CurrentConfiguration TargetConfiguration Property implementation The current memory redundancy status as follows: • 2 (Fully Redundant)-System is operating - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 73
position in the array contains one supported configuration. Possible values are: • Advanced ECC • Online Spare • Mirrored • RAID 7-3-6 HP_MemoryCollection The class HP_MemoryCollection represents physical memory collections on Integrity servers. The collection comprehends physical memory modules - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 74
Table 7-9 Class: HP_MemoryCollection Property name GroupStatusDescriptions HP_MemoryCollection Property implementation GroupStatusDescriptions[0] contains descriptive text per GroupOperationalStatus[0]: • Memory collection status: OK • Memory collection status: Degraded • Memory collection status: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 75
Table 7-11 Class: HP_HostedMemoryCollection Property name Antecedent Dependent Property implementation ref: HP_ComputerSystem ref: HP_MemoryCollection 7-3-8 HP_MemberOfMemoryCollection The class HP_ MemberOfMemoryCollection represents an association between HP_MemoryCollection and HP_MemoryModule - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 76
Antecedent Dependent Property implementation ref: HP_MemoryModule ref: HP_Memory 7-3-12 HP_ MemoryModuleSlot The class HP_MemoryModuleSlot represents memory module slots on Integrity Servers. There is an instance of this class for each memory module socket in the system (whether the slot is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 77
physical location. The memory socket number where the memory slot is located. 7-3-13 HP_MemoryBoardSlot The class HP_MemoryBoardSlot represents memory board slots on Integrity Servers. There is an instance of this class for each memory board slot in the system (whether the slot is occupied or not - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 78
Table 7-17 Class: HP_MemoryBoardSlot Property name Tag Description ElementName CIM_PhysicalConnector ConnectorLayout ConnectorDescription CIM_Slot Number HP_MemoryBoardSlot Property implementation HPQ:HP_MemoryBoardSlot:x, where x is the board/cartridge number. A string describing the memory board - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 79
ref: HP_MemoryModuleSlot 7-3-17 HP_MemoryModuleSlotLocation The class HP_MemoryModuleSlotLocation extends the HP_Location class and represents memory module slot locations on Integrity servers. There is an instance of this class for each memory module slot in the system (whether the slot - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 80
the board/cartridge number 7-3-18 HP_MemoryBoardSlotLocation The class HP_MemoryBoardSlotLocation extends the HP_Location class and represents memory board slot locations on Integrity Servers. There is an instance of this class for each memory board slot in the system (whether the slot is occupied - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 81
Table 7-22 Class: HP_ MemoryBoardSlotLocation Properties Description ElementName CIM_Location Name PhysicalPosition HP_Location ElementLocationTag ElementLocationTagDesc LocationInformation LocationInfoDesc HP_MemoryBoardSlotLocation Property implementation A string describing the physical location - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 82
7-3-20 HP_MemoryBoardSlotElementLocation The class HP_MemoryBoardSlotElementLocation extends the class HP_ElementLocation and is used to associate a memory board slot (HP_MemoryBoardSlot) with its corresponding location (HP_MemoryBoardSlotLocation). There is an instance of this class for each memory - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 83
7-26 Class: HP_SystemMemoryBoardSlot Properties HP_SystemMemoryBoardSlot GroupComponent PartComponent Property implementation ref: HP_ComputerSystemChassis ref: HP_MemoryBoardSlot 7-4 Supported indications There are no indications specific to the system memory profile implementation. 6BSystem - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 84
8 PCI Device 8-1 Overview This provider implements the profiles listed to support PCI devices installed in Integrity servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles Provider Installation Files • DMTF PCI - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 85
PCI device Vendor ID as described in the configuration registers for this PCI device 8-3-2 HP_PCIBridge HP_PCIBridge is used to model PCI bridge devices on Integrity servers. There is an instance of this class for each logical PCI bridge device that has been detected in the system. Table 8-3 Class - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 86
Table 8-3 Class: HP_PCIBridge Property name ElementName CIM_ManagedSystemElement Name CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_PCIController CIM_PCIDevice BusNumber DeviceNumber - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 87
describing the physical location of the PCI device. 2 (Not Applicable) 9 (Module/Card) HPQ:PCICard False 8-3-4 HP_PCISlot HP_PCISlot represents PCI device slots on Integrity Servers. There is an instance of this class for each PCI slot in the system (whether the slot is occupied or not). Table - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 88
a PCI Express slot, otherwise this property is not set The physical PCI slot number • True-if slot supports PCI hot plug operations • False-if slot does not support PCI hot plug operations HPQ:PCICard 8-3-5 HP_PCICardInSlot HP_PCICardInSlot is used to represent an association between HP_PCICard and - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 89
Property name GroupComponent PartComponent Property implementation References HP_ComputerSystem References HP_PCIDevice 8-3-9 HP_Location HP_Location is used to model PCI slot locations on Integrity Servers. The Windows-specific implementation class is HP_PCISlotLocation. 7BPCI Device 89 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 90
is HP_PCISlotElementLocation. Table 8-11 Class: HP_ElementLocation Property name Element PhysicalLocation Property implementation References CIM_ManagedElement References CIM_Location 8-4 Supported indications There are no indications specific to the PCI device implementation. 7BPCI Device 90 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 91
HPWmiMgmtProc.dll • HPWmiMgmtProcLite.mof 9-2 Use cases For use cases, see the HP Management Processor (MP) Lite Profile. 9-3 Class implementations The following classes are implemented for Integrity server platforms where available. The following classes describe management processor systems and - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 92
Inactive/Disabled and is the name of the MP product (same as the product name in property ElementName) For example, Active HP Management Processor - Integrated Lights Out (iLO) Product name of the management processor. Examples: • Remote Insight Board Lights Out Edition II (RILOE-II - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 93
/disabled MP 12 (Not Applicable) 2 (Enabled) HP_ManagementProcessor Product name of the management processor Examples: • Remote Insight Board Lights Out Edition II (RILOE-II) • Integrated Lights Out (iLO) • Integrated Lights Out 2 (ILO2) 14 (Management) 4 (Enabled) 8BManagement Processor Lite 93 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 94
of the MP-resident network interface The Uniform Resource Locator of the management processor controller's web-based user interface. An array of values indicating the protocols supported by the management processor controller. It is assumed that any protocol listed is active and can be utilized - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 95
Remote Insight Board Lights Out Edition II (RILOE-II) • Integrated Lights Out (iLO) • Integrated Lights Out 2 (ILO2) 2 (OK) Management Processor Firmware MajorVersion and MinorVersion properties. Hewlett-Packard 10 (Firmware) HP Management Processor Firmware HPQ:xxx, where xxx represents the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 96
Collection 1 HPQ:HP_MPCollection:001 Management Processor Collection 1 Describes the group operational status of the management processor collection (refer to HP Management Processor (MP) Lite Profile). The group operational status represents the 'worst-of' algorithm for all individual MP statuses - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 97
Table 9-4 Class: HP_MPCollection Property name GroupStatusDescription HP_MPCollection Property implementation GroupStatusDescriptions[0] text per GroupOperationalStatus[0]: • Aggregate Management Processor Collection Status: Unknown • Aggregate Management Processor Collection Status: OK • Aggregate - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 98
Table 9-6 Class: HP_MPComponentCS Property name PartComponent Property implementation ref: HP_ManagementProcessor 9-3-6 HP_MPMemberOfCollection HP_MPMemberOfCollection extends the class CIM_MemberOfCollection and associates a management processor to the collection to which it belongs. The - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 99
Property name CIM_InstalledSoftwareIdentity HP_MPInstalledFirmwareIdentity System InstalledSoftware Property implementation ref: HP_ManagementProcessor ref: HP_MPFirmware 9-4 Supported indications There are no indications specific to the management processor profile implementation. 8BManagement - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 100
Log 10-1 Overview This provider supports the IPMI System Event Log (SEL) on Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 10-1 Overview Implemented Profiles Provider Installation Files • HP Record Log Profile (P00109 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 101
Table 10-2 Class: HP_CommonRecordLog Properties Property name OperationalStatus StatusDescriptions HealthState CIM_LogicalElement CIM_EnabledLogicalElement EnabledState RequestedState EnabledDefault CIM_Log MaxNumberOfRecords CurrentNumberOfRecords LogState OverwritePolicy CIM_RecordLog InstanceID - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 102
currently used. Table 10-3 Implemented Methods for HP_CommonRecordLog Class Method Name ClearLog RepairAll Method Implementation See HP Record Log profile (P00109) See HP Record Log profile (P00109) 10-3-2 HP_CommonLogEntry HP_CommonLogEntry extends the class CIM_ LogEntry to model logs records - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 103
. For example, "OS agent in cabinet 0, cell slot 0" • 0 (Unknown) • 2 (Information) • 3 (Repaired) • 4 (Degraded/Warning) • 7 (Critical) • For Windows Server 2003 64-bit: 70 • For Windows Server 2008 64 bit: 77 • Unknown: 0 System serial number string System product ID string System model number - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 104
name ServerHardwareArchitecture LoggerType Property implementation • 0 (Unknown) • 8 (IA-64) 2 (Server) Table 10-5 Implemented Methods for HP_CommonLogEntry Class Method Name Repair Method Implementation Refer to HP Record Log profile (P00109) 10-3-3 HP_LogManagesRecord HP_ LogManagesRecord - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 105
10-4 Supported indications There are no indications specific to the profile registration profile implementation. 9BSEL Record Log 105 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 106
System Lite Profile 1.0 • HPWmiBlade.DLL • HPWmiBlade.mof 11-2 Use cases For use cases, see the HP Blade System Lite Profile. 11-3 Class implementations The following classes are implemented for Integrity c-Class blade systems only. The following classes reside in the local host OS CIMOM on each - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 107
status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 108
The URL of the enclosure's management web-based user interface 11-3-2 HP_BladeEnclosureCollection HP_BladeEnclosureCollection extends the class server blade enclosures with group aggregate status Server Blade Enclosure Collection HPQ:HP_BladeEnclosureCollection:001 Server - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 109
Property implementation ref: HP_ComputerSystem (the blade enclosure computer system) ref: HP_ComputerSystem (the blade servers computer system) 11-3-4 HP_MemberOfBladeEnclosureCollection HP_MemberOfBladeEnclosureCollection extends the class CIM_MemberOfCollection and associates the enclosure - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 110
CIM_LogicalElement CIM_SoftwareIdentity InstanceID MajorVersion Property implementation Server Blade Enclosure Firmware HP Server Blade Enclosure Firmware OA If enclosure name exists: HP BladeSystem c-Class enclosure otherwise: HP BladeSystem c-Class enclosure 2 (OK), normal - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 111
the string translation of the content provided in the MajorVersion and MinorVersion properties. Hewlett-Packard 10 (Firmware) HP Server Blade Enclosure Firmware HPQ:OA CIM:SoftwareFamily 11-3-7 CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates a blade enclosure to its corresponding - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 112
Property name CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System InstalledSoftware Property implementation ref: HP_BladeEnclosureCS ref: HP_BladeEnclosureFW 11-4 Supported indications There are no indications specific to the blade system profile implementation. 10BBlade - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 113
are installed by this provider. Table 12-1 Overview Implemented Profiles Provider Installation Files HP Ethernet Teaming 1.0 • HPWinEthAdapterCollection.dll • HPWinEthBootcodeVersion.dll • HPWinEthBootcodeVersionToPort.dll • HPWinEthDevice.dll • HPWinEthernetPort.dll • HPWinEthernetPortStatistics - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 114
.mof • HPWinIPBindsToEthLANEndpoint.mof 12-2 Use cases For use cases, see the HP Ethernet Teaming Profile. 12-3 Class implementations The following classes are implemented for Integrity server platforms. The following classes describe Ethernet Ports, Ethernet Teams and Ethernet LAN - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 115
otherwise 2 (OK) if port has link, 6 (Error) otherwise 2 (Enabled). Disabled ports are not modeled 5 (Not Applicable) HP_WinEthernetPort System GUID for the port HPQ: Spare Part Number Spare part number HP_ ComputerSystem.SystemCreationClassName HP_ComputerSystem.Name Port Type. See CIM_EthernetPort - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 116
MinNumberNeeded OtherLoadBalanceAlgorithm RedundancyStatus Property implementation Device Name (for example HP Network Team #1) Local Area Connection # (for example Local Area Connection #10) Same as Caption System GUID for the team. • 0 (None) • 1 (Other) • 3 (Round Robin) Number of - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 117
Key:Collection Key:Member HP_EthernetTeamMember MemberOperationalStatus MemberStatusDescriptions Property implementation ref: HP_EthernetTeam ref:HP_EthernetPort • 2 (OK) • 3 (Degraded) • 6 (Error) See the HP Ethernet Teaming Profile. Example: Degraded (Fast Path) 11BEthernet Teaming 117 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 118
• For Ethernet Teams, same as associated HP_WinEthRedundancySet.Caption • For Ethernet Ports, same as associated HP_WinEthernetPort.Caption Local Area Connection # Same as Caption System GUID for the Ethernet LAN Endpoint • 5 (OK) • 15 (Degraded/Warning) • 20 (Major Failure) 11BEthernet Teaming 118 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 119
VLANId VLANName Property implementation • 2 (OK) • 3 (Degraded) • 6 (Error) 2 (Enabled) 12 (Not Applicable) HP_WinEthLANEndpoint HP_ComputerSystem.CreationClassName Name of Server GUID 6 (Ethernet CSMA/CD) Current MAC Address Max Frame Size in bits VLAN Identifier, if LAN Endpoint is a VLAN, not - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 120
12-3-8 HP_EthernetTeamToLANEndpoint HP_ EthernetTeamToLANEndpoint associates Ethernet Teams to Ethernet LAN Endpoints. The Windows implementation class is HP_WinEthRedundancySetToLANEndpoint. Table 12-9 Class: HP_EthernetTeamToLANEndpoint Property name CIM_Dependency Key:Antecedent Key:Dependent - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 121
12-3-11 HP_EthernetStatistics The following table lists the property implementation for HP_EthernetPortStatistics. The Windows implementation class is HP_WinEthernetPortStatistics. 11BEthernet Teaming 121 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 122
same as associated HP_WinEthRedundancySet.Caption • For Ethernet Ports, same as associated HP_WinEthernetPort.Caption Local Area Connection # Same as Caption System GUID of the associated Ethernet Port or LAN Endpoint 0 Time of current statistics Total number of bytes received Total number of bytes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 123
Table 12-13 Class: HP_EthernetPortStatisticalData Property name CIM_ElementStatisticalData Key:ManagedElement Key:Stats HP_EthernetPortStatisticalData Property implementation ref:HP_EthernetPort ref:HP_EthernetStatistics 12-3-13 HP_EthernetLANEndpointStatisticalData - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 124
12-3-15 HP_EthernetMemberOfCollection HP_EthernetMemberOfCollection associates Ethernet Ports and Ethernet Teams to the Ethernet Collection. The Windows implementation class is HP_WinEthMemberOfCollection. Table 12-16 Class: HP_EthernetMemberOfCollection Property name CIM_MemberOfCollection Key: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 125
CIM_IPProtocolEndpoint IPv4Address SubnetMask Property implementation System GUID for the associated Ethernet LAN Endpoint, (Enabled) 12 (Not Applicable) HP_WinEthIPProtocolEndpoint HP_WinComputerSystem Name of Server 4096 (IPv4) IPV4 Address Subnet Mask 12-3-18 HP_EthIPHostedAccessPoint - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 126
Manufacturer MinorVersion TargetType VersionString Property implementation Same as associated Ethernet Port Same as associated Ethernet Port PCI vendor ID System GUID for the associated Ethernet Port Same as associated Ethernet Port Same as associated Ethernet Port Firmware 10 (Firmware) System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 127
[0] HP_WinEthLocation Property implementation Same as associated ethernet port Same as associated ethernet port Same as caption Local Area Connection # System GUID for the associated Ethernet Port PCI Bus:Device:Function 15 (PCI Bus:Device:Function) 0 (Slot) or 1 (Mezzanine Slot) or 2 (Interconnect - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 128
Ethernet Indication settings. The Windows implementation class is HP_WinEthEventSettings. Table 12-24 Class: HP+EthEventSettings Property name CIM_SettingData Caption Description ElementName Key:InstanceId HP_EthEventSettings HP_WinEthEventSettings ActiveAdapterCountChanged FloodThreshold - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 129
Table 12-24 Class: HP+EthEventSettings Property name MonitorLANEndpoints utilization. Default 200. 12-4 Supported indications The following indications are implemented for Integrity server platforms where available. System Ethernet Provider Name Property implementation GUID string generated at - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 130
View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log build> 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 131
AlertType Event Id Provider Name RecommendedActions[] SystemCreationClassName SystemName HP_AlertIndication Summary EventCategory EventSubCategory NetworkAddresses Property implementation GUID string generated at indication 2 (Information) Time of indication The Ethernet Team has transitioned from - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 132
2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer Property name CIM_Indication IndicationIdentifier Property implementation GUID string generated at indication 11BEthernet Teaming - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 133
Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 134
Restored Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingManagedElement AlertingElementFormat Property implementation GUID string generated at indication 2 (Information) Time of indication The Ethernet Team has transitioned - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 135
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 136
RecommendedActions[] SystemCreationClassName SystemName Property implementation GUID string generated at indication 6 ( Lost Connectivity Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information. - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 137
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 138
AlertType Event Id Provider Name RecommendedActions[] SystemCreationClassName SystemName HP_AlertIndication Summary EventCategory EventSubCategory NetworkAddresses Property implementation GUID string generated at indication 2 (Information) Time of indication If the Network Interface is an Ethernet - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 139
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 140
OSType OSVersion ProviderVersion SystemFirmwareVersion Property implementation GUID string generated at indication 2 Alert) 10 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information. - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 141
[2] VariableName[3] VariableTypes[3] VariableValue[3] VariableName[4] VariableTypes[4] VariableValue[4] ImpactedDomain BladeBay * BladeName * EnclosureName * Property implementation Platform GUID of the computer system generating the indication Model name of the computer system generating the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 142
HP_AlertIndication Summary EventCategory EventSubCategory Property implementation GUID string generated at indication 2 (Information Alert) 9 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 143
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 144
Summary EventCategory EventSubCategory NetworkAddresses Property implementation GUID string generated at indication 2 (Information ) 8 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 145
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 146
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 147
Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingManagedElement AlertingElementFormat AlertType Property implementation GUID string generated at indication 3 (Degraded/Warning) Time of indication An existing network interface - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 148
Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for > 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 149
AlertType Event Id Provider Name RecommendedActions[] SystemCreationClassName SystemName HP_AlertIndication Summary EventCategory EventSubCategory Property implementation GUID string generated at indication 2 (Information) Time of indication A new network interface is available. This - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 150
2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime Property implementation GUID string generated at indication 2 (Information - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 151
13 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 152
HP_AlertIndication: Fatal Error Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingManagedElement Property implementation GUID string generated at indication 2 (Information) Time of indication A fatal error occurred. WBEM path - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 153
) 2 (Communications Alert) 1 Ethernet Contact HP Support. CreationClassName of the computer system generating the indication build> 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 154
AlertType Event Id Provider Name RecommendedActions[] Property implementation GUID string generated at indication 2 (Information) Time of of this event are not a cause for concern. Numerous instances of this event indicate a serious issue. Contact HP Support. 11BEthernet Teaming 154 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 155
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 156
Table 12-39 Optional HP_AlertIndication: Warning Property name SystemVirtualUUID Property implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment 11BEthernet Teaming 156 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 157
This provider implements a read-only version of the profiles referenced. Configuration functionality is not supported by this provider. This is in accordance with the SNIA profiles, because HP does not advertise and ConfigurationService type classes. 13-3 Class implementations The following sections - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 158
Failure • Physical Drive Degraded/Failed 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSA_ArraySystem Controller Serial Number Other • Dedicated[0]: 3 (Storage) • Dedicated[1]: 15 (Block Server) Other Vendor Specific Name Controller Serial Number See HP Smart Array Profile 12BSmart Array 158 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 159
Controller Serial Number Other Dedicated[0] 0 (Not Dedicated) See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile 12BSmart Array 159 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 160
NumberOfPorts RebuildPriority Property implementation See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile 13-3-3 HPSA_StorageVolume - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 161
or above • False - RAID 0 Total Number of blocks on the volume. • 0 (RAID 0) • 1 (RAID 1+0, RAID 5) • 2 (RAID 6) 2 (VPD83NAA6) See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile Volume status. DMTF defined value is populated in index[0] and extended status is poplulated - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 162
HPSA_ArraySystem.Name Number of service hours logged for the drive See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile 13 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 163
: • 2 (None) • 11 (Rebuild - disk drive is currently rebuilding data) Total number of blocks on disk drive Set to True Total service hours reported disk drive 13-3-6 HPSA_DiskDriveFirmware HPSA_DiskDriveFirmware represents the firmware installed on a disk drive. There is one instance per disk drive - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 164
Table 13-7 Class: HPSA_DiskDriveFirmware (CIM_SoftwareIdentity) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_LogicalElement Caption Description CIM_SoftwareIdentity ClassificationDescriptions[0] Classifications[0] InstanceID Manufacturer IdentityInfoType - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 165
Table 13-8 Class: HPSA_PhysicalPackage (CIM_PhysicalPackage) Property name Manufacturer Model PartNumber SerialNumber Tag Version CIM_PhysicalPackage RemovalConditions HPSA_PhysicalPackage Property implementation Controller vendor string Controller model string N/A-Not Available for this - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 166
Table 13-9 Class: HPSA_ArrayControllerPhysicalPackage (CIM_PhysicalPackage) Property name HPSA_ ArrayControllerPhysicalPackage Property implementation 13-3-9 HPSA_DiskPhysicalPackage HPSA_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive. - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 167
the port and is the box number Port: Box: , where is the port and is the box number HPSA_StorageEnclosure Enclosure vendor string e.g HP For example, N/A if not available Enclosure model string For example, PROLIANT 6L6I For example, N/A if not available N/A-Not Available in this - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 168
Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows. • Index[0] - Enclosure status: ○ 0 (Unknown) ○ 2 (OK) ○ 3 (Degraded) ○ 6 (Error) • Index[1] - Fan - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 169
Table 13-13 Class: HPSA_PortController (CIM_PortController) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 170
Table 13-14 Class: HPSA_DAPort (CIM_DAPort) Property name CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort UsageRestriction CIM_DAPort HPSA_DAPort Property implementation 2 (Enabled) - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 171
Table 13-15 Class: HPSA_SPIPort (CIM_SPIPort) Property name CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort CIM_SPIPort HPSA_SPIPort Property implementation HPSA_SPIPort Opaque key HPSA_ArraySystem HPSA_ArraySystem.Name 13-3-15 HPSA_Firmware HPSA_Firmware represents - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 172
Table 13-17 Class: HPSA_EnclosureFirmware (CIM_SoftwareIdentity) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_LogicalElement Caption Description CIM_SoftwareIdentity ClassificationDescriptions[0] Classifications[0] InstanceID Manufacturer IdentityInfoType - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 173
managed by this pool 13-3-19 HPSA_MediaAccessStatData HPSA_MediaAccessStatData represents the Monitoring and Performance data counters on HP Disk Drives. Table 13-20 Class: HPSA_MediaAccessStatData (CIM_MediaAccessStatData) Property name CIM_ManagedElement Property implementation 12BSmart Array - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 174
HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 175
Table 13-21 Class: HPSA_StorageSetting (CIM_StorageSetting) Property name CIM_ManagedElement ElementName CIM_SettingData InstanceID CIM_StorageSetting ChangeableType DataRedundancyGoal DataRedundancyMax DataRedundancyMin DeltaReservationGoal DeltaReservationMax DeltaReservationMin - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 176
Table 13-22 Class: HPSA_DriveCage (CIM_PhysicalPackage) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_PhysicalElement CreationClassName Manufacturer Model PartNumber Tag SerialNumber Version CIM_PhysicalPackage RemovalConditions HP_DriveCage BackplaneSpeed DriveBays - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 177
Table 13-23 Class: HPSA_SCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name EnabledDefault RequestedState CIM_ServiceAccessPoint CreationClassName Name SystemCreationClassName SystemName CIM_ProtocolEndpoint ProtocolIFType CIM_SCSIProtocolEndpoint ConnectionType OtherConnectionType Role - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 178
Table 13-24 Class: HPSA_SCSIProtocolController (CIM_SCSIProtocolController) Property name CreationClassName DeviceID SystemCreationClassName SystemName CIM_ProtocolController MaxUnitsControlled CIM_ SCSIProtocolController HPSA_ SCSIProtocolController Property implementation - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 179
Table 13-26 Class: HPSA_StorageRedundancySet (CIM_StorageRedundancySet) Property name CIM_ManagedElement ElementName CIM_Collection CIM_SystemSpecificCollection InstanceID CIM_RedundancySet LoadBalanceAlgorithm MaxNumberSupported MinNumberNeeded RedundancyStatus TypeOfSet[0] - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 180
13-3-27 HPSA_DriveCageLocation HPSA_DriveCageLocation represents a location string for the drive cage. Table 13-28 Class: HPSA_DriveCageLocation (HP_Location) Property name CIM_ManagedElement Caption Description ElementName CIM_Location Name PhysicalPosition HP_Location ElementLocationTag - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 181
Table 13-29 Class: HPSAArraySystemLocation (HP_Location) Property name ElementName CIM_Location Name PhysicalPosition HP_Location ElementLocationTag ElementLocationTagDesc LocationInformation[0] LocationInfoDesc[0] HPSA_ArraySystemLocation Property implementation Controller name and location - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 182
in ElementLocationTagDesc. • SCSI ID of Disk Drive-When 'SCSI ID' is specified in ElementLocationTagDesc • 20 (Bay)-When firmware supports Bay numbering • 21 (SCSI ID) 13-3-30 HPSA_ArrayControllerLocation HPSA_ArrayControllerLocation represents a location string for the array controller. Table 13 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 183
Table 13-31 Class: HPSA_ArrayControllerLocation (HP_Location) Property name ElementLocationTag ElementLocationTagDesc LocationInformation[0] LocationInfoDesc[0] HP_ArrayControllerLocation Property implementation for Internal HBAs: PCI Slot Number Examples: • 3 - for adapter in PCI Slot 3 • 0 - for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 184
Table 13-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities) Property name DataRedundancyDefault DataRedundancyMax DataRedundancyMin DeltaReservationDefault DeltaReservationMax DeltaReservationMin ElementType NoSinglePointOfFailure NoSinglePointOfFailureDefault PackageRedundancyDefault - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 185
CIM_Product) Property name IdentifyingNumber Name Vendor Version HPSA_Product Property implementation Opaque key String representing the Marketing name HP Firmware version of HBA or Storage System 13-3-33 HPSA_StorageEnclosure Location HPSA_StorageEnclosureLocation represents a location string for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 186
13-3-35 HPSA_StorageVolumeStorageSetting (Association) Table 13-36 Class: HPSA_StorageVolumeStorageSetting (CIM_ElementSettingDate) Property name ManagedElement SettingData IsCurrent IsDefault Property implementation HPSA_StorageVolume HPSA_StorageSetting 1 (Set to Is Current) 1 (Set to Is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 187
Table 13-40 Class: HPSA_ArraySystemSCSIProtocolController (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSA_ArraySystem HPSA_SCSIProtocolController 13-3-40 HPSA_ArraySystemPortController (Association) Table 13-41 Class: HPSA_ArraySystemPortController ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 188
13-3-44 HPSA_ArraySystemSPIPort (Association) Table 13-45 Class: HPSA_ArraySystemSPIPort (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSA_ArraySystem HPSA_SPIPort. 13-3-45 HPSA_ArraySystemDAPort (Association) Table 13-46 Class: HPSA_ArraySystemDAPort ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 189
13-3-49 HPSA_ArraySystemArrayController (Association) Table 13-50 Class: HPSA_ArraySystemArrayController (CIM_ComponentCS) Property name GroupComponent PartComponent Property implementation HPSA_ArraySystem HPSA_ArrayController 13-3-50 HPSA_StorageEnclosureStorageEnclosureProcessor (Association) - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 190
Table 13-54 Class: HPSA_PhysicalPackageArrayControllerPhysicalPackage (CIM_Container) Property name GroupComponent PartComponent Property implementation HPSA_PhysicalPackage HPSA_ArrayControllerPhysicalPackage 13-3-54 HPSA_PhysicalPackageDiskPhysicalPackage (Association) Table 13-55 Class: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 191
13-3-58 HPSA_PrimordialPoolStorageExtent (Association) Table 13-59 Class: HPSA_PrimordialPoolStorageExtent (CIM_ConcreteComponent) Property name GroupComponent PartComponent Property implementation HPSA_PrimordialPool HPSA_StorageExtent 13-3-59 HPSA_StorageSpecificCollectionArraySystem ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 192
Table 13-63 Class: HPSA_ArraySystemFirmware (CIM_InstalledSoftwareIdentity) Property name InstalledSoftware System Property implementation HPSA_Firmware HPSA_ArraySystem 13-3-63 HPSA_SCSIProtocolControllerStorageVolume (Association) Table 13-64 Class: HPSA_SCSIProtocolControllerStorageVolume ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 193
13-3-66 HPSA_DiskDriveDiskDriveFirmware (Association) Table 13-67 Class: HPSA_DiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSA_DiskDriveFirmware HPSA_DiskDrive • ElementSoftwareStatus[0]: 2 (Current) • - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 194
Table 13-71 Class: HPSA_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Antecedent Dependent SpaceConsumed Property implementation HPSA_PrimordialPool HPSA_StoragePool Bytes consumed by storage pool 13-3-71 HPSA_SpareExtentStorageExtent (Association) Table 13-72 Class: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 195
13-3-75 HPSA_SPIPortSCSIProtocolEndpoint (Association) Table 13-76 Class: HPSA_SPIPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Antecedent Dependent Property implementation HPSA_SPIPort HPSA_SCSIProtocolEndpoint 13-3-76 HPSA_StorageGroupHostedCollection (Association) - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 196
Table 13-80 Class: HPSA_DiskDriveMediaAccessStatData (CIM_ElementStatisticalData) Property name Stats Property implementation HPSA_MediaAccessStatData 13-3-80 HPSA_ArrayControllerPhysicalPackageArrayControllerLo cation (Association) Table 13-81 Class: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 197
Property implementation HPSA_StorageEnclosure HPSA_StorageEnclosureLocation 13-4 Supported indications Table 13-87 HPSA_DeviceIndication: Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at indication 2 (Informational - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 198
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 199
Physical Drive status changed to ERROR Property name CIM_Indication IndicationIdentifier PerceivedSeverity Property implementation GUID string generated at indication Severity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 200
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 201
IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName Property implementation GUID string generated at indication 2 (Informational) Time of indication Physical Drive status has - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 202
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 203
CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Property implementation GUID string generated at indication 5 (Major) Time of indication Physical Drive status has - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 204
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 205
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 2 (Informational) Time of indication Logical Drive status has now - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 206
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 207
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 5 (Major) Time of indication Logical Drive Status has changed - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 208
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 209
ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Logical Drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost. WBEM - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 210
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 211
Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Array Controller Status has changed - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 212
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]:CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 213
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 5 (Major) Time of indication Array Controller Status has changed - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 214
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 215
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 3 (Warning) Time of indication Controller Redundancy state has - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 216
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 217
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 3 (Warning) Time of indication Controller has detected that - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 218
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 219
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 2 (Info) Time of indication Controller has detected that Redundancy - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 220
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 221
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 2 (info) Time of indication Array Controller Battery Status has - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 222
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 223
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 3 (Warning) Time of indication Controller Battery Status is set - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 224
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 225
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 5 (major) Time of indication Controller Battery Status set to - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 226
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 227
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 2 (Info) Time of indication Array Controller Cache Status has - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 228
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 229
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 2 (Info) Time of indication Array Controller Cache Status is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 230
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 231
Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 3 (Warning) Time of indication Array Controller Cache Status is set to a status of Permanently Disabled. Controller has detected a problem with the cache and has disabled - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 232
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 233
Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 3 (Warning ) 5 (Device Alert) 1502 SmartArray Check status of all enclosure power supplies. Problem may be caused by a failed power supply. Name of the computer system generating - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 234
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 235
HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType OSVersion ProviderVersion SystemFirmwareVersion SystemSerialNumber SystemProductID SystemModel Property implementation GUID string generated at indication 2 (Info) Time of indication Power Supply Status changed to - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 236
changed to Redundant Degraded Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement Property implementation GUID string generated at indication 3 (Warning) Time of indication Power Supply Status changed to a status - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 237
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 238
Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Temperature sensor Status changed to - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 239
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 240
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType Property implementation GUID string generated at indication 3 (Warning) Time of indication Temperature sensor Status changed to Warning - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 241
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 242
HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType OSVersion ProviderVersion SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation GUID string generated at indication 5 (major) Time of indication Temperature sensor Status changed to - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 243
HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 244
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 245
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName Property implementation GUID string generated at indication 3 (Warning) Time of indication Fan Status changed to a status of Degraded. Enclosure has detected there may a problem with one or more of the fans. WBEM - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 246
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 247
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType Property implementation GUID string generated at indication 5 (major) Time of indication Enclosure Fan Status changed to a status - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 248
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 249
implemented and files installed by this provider. Table 14-1 Overview Implemented Profiles Requirements Provider Installation Files • HP FC HBA Profile 1.0 • HBAAPI.dll that supports the SNIA Common HBA API, Version 2.18 • Dll(s) • HPWMISCSI.dll • HPWMISCSIEventMsg.dll • Cpqmdisk.dll • Cpqmscsi - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 250
Figure 14-1 Instance diagram for a single HBA with two controllers with one port on each controller 13BFC HBA 250 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 251
14-2-1 Get statistics for each Fibre Channel port 1. For each instance of HPFCHBA_ComputerSystem, find the corresponding instance of the associations HPFCHBA_ComputerSystemFCPort. 2. For each association of HPFCHBA_ComputerSystemFCPort, get the corresponding instance of HPFCHBA_FCPort. 3. For each - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 252
7. For each instance of association HPFCHBA_SoftwareIdentityDrvPortController, get the corresponding instance of HPFCHBA_SoftwareIdentityDrv. The VersionString property contains the driver version. Other properties of interest are Description, ElementName, and Manufacturer. 8. For each instance of - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 253
Figure 14-3 Discover HBA topology and attributes 14-3 Class implementations 14-3-1 HPFCHBA_ComputerSystem HPFCHBA_ComputerSystem is used to identify classes that represent the all Fibre Channel ports. Table 14-2 Class: HPFCHBA_ComputerSystem Property name CIM_ManagedElement Property - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 254
(OK) • 3 (Degraded) • 6 (Error) • Unknown • Other • OK • Degraded • Error 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPFCHBA_ComputerSystem Other 0 HPQ:GUID 85408DBD-6A39-41CD-9E5A-357AEA130BBF 14-3-2 HPFCHBA_FCPort HPFCHBA_FCPort is used to represent a Fibre Channel port device. Table 14 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 255
2 (OK-Online) • 6 (Error) • 10 (Stopped) • 11 (In Service) • Unknown • OK-Online • Offline • Bypassed • Diagnostics • Link down • where nodeWWN is the node's WWN and portWWN is the port's WWN. HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn, where nodewwn is the node's WWN. - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 256
) 4 (FC) PortWWN Port number Port maximum frame size Array of port active FC4 type bits Array of port supported FC4 type bits 14-3-3 HPFCHBA_PortController HPFCHBA_PortController is a logical device corresponding to a hardware network port controller. Table 14-4 Class: HPFCHBA_PortController - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 257
(Not Applicable) 12 (Not Applicable) HPFCHBA_PortController NodeWWN:SerialNumber HPFCHBA_ComputerSystem HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn, where nodewwn is the node PacketsReceived Property implementation Product name HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 258
InstanceID CIM_LogicalPortGroup Name NameFormat Property implementation Grouping of all FC Ports for this HBA Logical Port Group Logical Port Group HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_L ogicalPortGroup, where nodewwn is the node's WWN. NodeWWN WWN 13BFC HBA 258 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 259
(Other) 2 (OK) 3 (Degraded) 6 (Error) HPFCHBA_PhysicalPackage Manufacturer Model Location; PCI Slot x where x is the PCI slot number Serial Number HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn where nodewwn is the node's WWN. Board Version or N/A when not available 2 (Not Applicable - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 260
Device Driver, where product name is the product name of the HBA. FC HBA Driver NodeWWN FC HBA Driver 2 (Driver) HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_S oftwareIdentityDrv where nodewwn is the node's WWN. Manufacturer Driver version 14-3-9 HPFCHBA_FirmwareIdentityFW - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 261
for Product Name, where product name is the product name of the HBA. FC HBA Firmware NodeWWN FC HBA Firmware 10 (firmware) HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_Fi rmwareIdentityFW, where nodewwn is the node's WWN Manufacturer Serial number Firmware version 14-3-10 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 262
FC HBA Option ROM 11 (bios/fc) HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_Fi rmwareIdentityBIOS, where is the node's WWN Manufacturer BIOS Version as reported by HBA HP BIOS UNKNOWN Serial Number 0 0 0 14-3-11 HPFCHBA_SCSIProtocolController HPFCHBA_SCSIProtocolController - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 263
CIM_ProtocolController MaxUnitsControlled CIM_SCSIProtocolController Property implementation HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn NodeWWN 2 (Enabled) 12 (Not Applicable) HPFCHBA_ComputerSystem HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn, where nodewwn is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 264
FC HBA Consolidated Status A consolidated OperationalStatus for all FCHBA_ComputerSystem instances FC HBA Consolidated Status HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:HPFCHBA_GroupSystemSpecificColle ction • 0 (Unknown) • 1 (Other) • 2 (OK) • 3 (Degraded) • 6 (Error) • Unknown • Other • OK - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 265
14-3-15 HPFCHBA_ComputerSystemPortController HPFCHBA_ComputerSystemPortController is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_PortController. Table 14-16 Class: HPFCHBA_ComputerSystemPortController Property name CIM_Component CIM_SystemDevice - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 266
Table 14-18 Class: HPFCHBA_ComputerSystemLogicalPortGroup Property name Dependent Property implementation ref:HPFCHBA_LogicalPortGroup 14-3-18 HPFCHBA_ComputerSystemSoftwareIdentityDrv HPFCHBA_ComputerSystemSoftwareIdentityDrv is used to represent an association between HPFCHBA_ComputerSystem and - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 267
Table 14-21 Class: HPFCHBA_FCPortFCPortStatistics Property name CIM_ElementStatisticalData HPFCHBA_FCPortFCPortStatistics ManagedElement Stats Property implementation ref:HPFCHBA_FCPort ref:HPFCHBA_FcPortStatistics 14-3-21 HPFCHBA_FCPortLogicalPortGroup HPFCHBA_FCPortLogicalPortGroup is used to - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 268
Table 14-24 Class: HPFCHBA_SCSIProtocolControllerFCPort Property name CIM_Dependency CIM_ProtocolControllerForDevice CIM_ProtocolControllerForPort HPFCHBA_SCSIProtocolControllerFCPort Antecedent Dependent Property implementation ref:HPFCHBA_SCSIProtocolController ref:HPFCHBA_FCPort 14-3-24 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 269
HPFCHBA_SoftwareIdentityDrvPortController is used to represent an association between HPFCHBA_PortController and HPFCHBA_SoftwareIdentityDrv. Table 14-27 Class: HPFCHBA_SoftwareIdentityDrvPortController Property name CIM_Dependency CIM_ElementSoftwareIdentity - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 270
14-3-29 HPFCHBA_ProductPhysicalComponent HPFCHBA_ProductPhysicalComponent is used to represent an association between HPFCHBA_Product and HPFCHBA_PhysicalPackage. Table 14-30 Class: HPFCHBA_ProductPhysicalComponent Property name CIM_Component CIM_ProductPhysicalComponent - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 271
14-3-32 HPFCHBA_GroupHostedCollection HPFCHBA_GroupHostedCollection is used to represent an association between CIM_ComputerSystem and HPFCHBA_GroupSystemSpecificCollection. Table 14-33 Class: HPFCHBA_GroupHostedCollection Property name CIM_Dependency CIM_HostedDependency CIM_HostedCollection - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 272
Property name CIM_ElementLocation HPFCHBA_PhysicalElementLocation Element PhysicalLocation Property implementation ref:HPFCHBA_PhysicalPackage ref:HPFCHBA_Location 14-4 Supported indications There are no indications specific to the Fibre Channel profile implementation. 13BFC - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 273
provider implements a read only version of the profiles referenced. No configuration functionality is supported by this provider. This is in accordance with the SNIA profiles since HP does not advertise and ConfigurationService type classes. 15-3 Class implementations The following chapters define - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 274
of the Array System and attached devices. This is calculated as per the algorithm described in the HP SAS HBA Profile. • 0 (Unknown) • 2 (OK) • 3 (Degraded) • 6 Dedicated[0]: 3 (Storage) • Dedicated[1]: 15 (Block Server) Other Vendor Specific Name Controller Serial Number 15-3-2 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 275
EnabledState Property implementation Logical drive number with raid description For example, Logical Volume 1 (RAID 1) Concatenation of Vendor + Model + SerialNumber+Logical Drive number For example, HP+HP 8 INT Port SAS/SATA HBA+C007760405+LD1 2 (Enabled) 5 (Not Applicable) 14BSAS HBA 275 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 276
) False • True - RAID 1 or above • False - RAID 0 Total Number of blocks on the volume. • 0 (RAID 0) • 1 (RAID 1) 7 (SNVM) See HP SAS HBA Profile See HP SAS HBA Profile Volume status • 0 (Unknown) • 2 (OK) • 3 (Degraded) - RAID redundancy lost or rebuilding data • 6 (Error) Corresponding OS name for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 277
2 (OK) • 5 (Predictive Failure) • 6 (Error) 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSAS_DiskDrive Opaque value HPSAS_ArraySystem HPSAS_ArraySystem.Name See HP SAS HBA Profile See HP SAS HBA Profile See HP SAS HBA Profile See HP SAS HBA Profile See HP SAS HBA Profile 0 0 14BSAS HBA 277 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 278
15-3-5 HPSAS_StorageExtent HPSAS_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive. Table 15-6 Class: HPSAS_StorageExtent (CIM_StorageExtent) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 279
15-3-6 HPSAS_DiskDriveFirmware HPSAS_DiskDriveFirmware represents the firmware installed on a disk drive. There is one instance per disk drive. Table 15-7 Class: HPSAS_DiskDriveFirmware (CIM_SoftwareIdentity) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 280
Table 15-8 Class: HPSAS_PhysicalPackage (CIM_PhysicalPackage) Property name Name CIM_PhysicalElement CreationClassName Manufacturer Model PartNumber SerialNumber Tag CIM_PhysicalPackage RemovalConditions HPSAS_PhysicalPackage Property implementation Controller Serial Number HPSAS_PhysicalPackage - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 281
SystemName CIM_Controller CIM_PortController ControllerType OtherControllerType HPSAS_PortController Property implementation Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSAS_PortController - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 282
CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort UsageRestriction CIM_DAPort HPSAS_DAPort Property implementation Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 Port status • 0 (Unknown) • 2 (OK) • 6 (Error) 2 (Enabled) 5 (Not Applicable - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 283
CIM_LogicalElement CIM_StoragePool InstanceID PoolID Primordial RemainingManagedSpace TotalManagedSpace Property implementation Controller name and location: pool identifier. For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Primordial Pool Opaque key Controller serial number TRUE 0 Total raw - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 284
Property implementation Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Primordial CIM_ManagedSystemElement Property implementation Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Storage Pool 14BSAS - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 285
Table 15-15 Class: HPSAS_StoragePool (CIM_StoragePool) Property name CIM_LogicalElement CIM_StoragePool InstanceID PoolID Primordial RemainingManagedSpace TotalManagedSpace HPSAS_StoragePool Property implementation Opaque key Controller serial number:1 FALSE 0 Total raw space managed by this pool - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 286
ProtocolIFType CIM_SCSIProtocolEndpoint ConnectionType OtherConnectionType Role HPSAS_SCSIProtocolEndpoint Property implementation Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 2 (Enabled) 12 (Not Applicable) HPSAS_SCSIProtocolEndpoint HBA Serial - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 287
SystemCreationClassName SystemName CIM_ProtocolController MaxUnitsControlled CIM_SCSIProtocolController HPSAS_SCSIProtocolController Property implementation Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Operational status of the controller • 0 (Unknown) • 2 (OK - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 288
implementation SAS HBA Consolidated Status A consolidated OperationalStatus for all HPSAS_ArraySystem instances SAS HBA Consolidated Status Opaque key Consolidated status for all array controllers. See HP SAS HBA profile for details on how this is calculated Description of failure 14BSAS HBA 288 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 289
Port SAS/SATA HBA in Slot 3 Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Opaque key Opaque key PCI Slot number 23 (Adapter) PCI Slot number For example, 3 - PCI Slot 3 3 (PCI Slot - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 290
Pools Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 for internal • For Concrete Pools Controller name and location:Array identifier, for example, HP 8 INT Port SAS/SATA HBA in Slot 3: Storage Pool for internal Opaque key • 0 (When Pool is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 291
HPSAS_Product Property implementation Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3, for internal Opaque key String representing the Marketing Name HP Firmware version of HBA 15-3-24 HPSAS_DriveCage HPSAS_DriveCage represents the drive cage - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 292
Table 15-25 Class: HPSAS_DriveCage (CIM_PhysicalPackage) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_PhysicalElement CreationClassName Manufacturer Model PartNumber Tag SerialNumber Version CIM_PhysicalPackage RemovalConditions HP_DriveCage BackplaneSpeed - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 293
the port and is the box number Port: Box: , where is the port and is the box number HPSAS_StorageEnclosure Enclosure vendor string • HP • N/A, if not available Enclosure model string • MSA50 -10D25G1 • N/A, if not available N/A-Not Available in this implementation 14BSAS HBA 293 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 294
implementation 2 (Not Applicable) See HP Storage Enclosure Profile 15-3-27 HPSAS_StorageEnclosureProcessor power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows: • Index[0]-Enclosure status: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 295
Vendor Specific Name SDE - indicates Storage Device Enclosure Vendor:SerialNumber enclosure is attached to For example, HP:2SUJ1029 15-3-28 HPSAS_StorageEnclosureLocation HPSAS_StorageEnclosureLocation represents a location string for the enclosure. Table 15-29 Class: HPAS_StorageEnclosureLocation - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 296
15-3-29 HPSAS_DriveCageDiskDrive (Association) Table 15-30 Class: HPSAS_DriveCageDiskDrive (CIM_Container) Property name GroupComponent PartComponent Property implementation HPSAS_DriveCage HPSAS_DiskPhysicalPackage 15-3-30 HPSAS_StorageEnclosureDriveCage (Association) Table 15-31 Class: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 297
Table 15-34 Class: HPSAS_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSAS_EnclosureFirmware HPSAS_StorageEnclosureProcessor • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 298
15-3-37 HPSAS_PrimordialPoolNoRaidStorageCapabilities (Association) Table 15-38 Class: HPSAS_PrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Capabilities ManagedElement Property implementation HPSAS_StorageCapabilities HPSAS_PrimordialPoolNoRaid 15-3-38 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 299
Table 15-42 Class: HPSAS_ArraySystemDiskDrive (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSAS_ArraySystem HPSAS_DiskDrive 15-3-42 HPSAS_ArraySystemStorageVolume (Association) Table 15-43 Class: HPSAS_ArraySystemStorageVolume (CIM_SystemDevice) - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 300
15-3-46 HPSAS_ArraySystemPrimordialPoolNoRaid (Association) Table 15-47 Class: HPSAS_ArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) Property name GroupComponent PartComponent Property implementation HPSAS_ArraySystem HPSAS_PrimordialPoolNoRaid 15-3-47 HPSAS_ArraySystemStoragePool ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 301
Table 15-51 Class: HPSAS_ProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name GroupComponent PartComponent Property implementation HPSAS_Product HPSAS_PhysicalPackage 15-3-51 HPSAS_StoragePoolStorageExtent (Association) Table 15-52 Class: HPSAS_StoragePoolStorageExtent ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 302
Table 15-55 Class: HPSAS_StorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Collection Member Property implementation HPSAS_StorageSpecificCollection HPSAS_ArraySystem 15-3-55 HPSAS_StorageRedundancySetStorageExtent (Association) Table 15-56 Class: - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 303
Table 15-59 Class: HPSAS_FirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSAS_Firmware HPSAS_ArraySystem • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) 15-3-59 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 304
Table 15-63 Class: HPSAS_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Antecedent Dependent SpaceConsumed Property implementation HPSAS_PrimordialPool HPSAS_StoragePool Bytes consumed by storage pool 15-3-63 HPSAS_StorageExtentStorageVolume (Association) Table 15-64 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 305
(Association) Table 15-70 Class: HPSAS_SCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name AvailableSAP ManagedElement Property implementation HPSAS_SCSIProtocolEndpoint HPSAS_SCSIProtocolController 15-4 Supported indications 14BSAS HBA 305 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 306
SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation GUID string generated at the time Alert) 1 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system generating the indication CreationClassName of - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 307
HWLogicalLocation HWManufacturer HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 308
of the event or time of the indication if event time unknown HP SAS Replace the HBA. Name of the computer system generating the generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 309
AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions Property implementation GUID string generated at the time of indication 2 (Device Alert) 201 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. 14BSAS HBA 309 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 310
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 311
SystemCreationClassNameEventTime Property implementation GUID string generated at the Time of the event or time of the indication if event time unknownWBEM Path of disk drive HP SAS2 (CIMObjectPath) No action is recommended.5 (Device Alert) Name of the computer system generating the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 312
SystemGUID VariableNames VariableTypes VariableValues Property implementation HP SAS Redundant power supply status the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 313
REBUILDING Property name CIM_Indication IndicationIdentifier PreceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at the time of indication Severity For example, 2 (Information) Time of - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 314
the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 315
Property name CIM_Indication IndicationIdentifier PreceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID Property implementation GUID string generated at the time of indication 5 (Major) Time of indication A physical drive - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 316
the event or time of the indication if event time unknown HP SAS Replace drive immediately to avoid loss of data. Name of the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 317
AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions Property implementation GUID string generated at the time of indication 2 (Device Alert) 101 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. 14BSAS HBA 317 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 318
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 319
ProviderVersion NetworkAddresses OSType OSVersion Property implementation GUID string generated at the time of Device Alert) 102 Time of the event or time of the indication if event time unknown HP SAS Check for failed or removed physical drives. Name of the computer system generating the indication - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 320
CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at the time of indication 3 (Warning) Time of indication A logical drive is in a degraded state. Device is still servicing I/O, but redundancy may be degraded or lost - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 321
of the event or time of the indication if event time unknown HP SAS Check status of physical drives. Degraded status may be caused generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 322
Summary EventCategory ProbableCause ProbableCauseDescription Property implementation GUID string generated at the time of Alert) 301 Time of the event or time of the indication if event time unknown HP SAS Check status of all enclosure power supplies. Ensure that power supplies have not failed. - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 323
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 324
ProbableCauseDescription ProviderVersion NetworkAddresses OSType Property implementation GUID string generated at the time of 302 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system generating the indication CreationClassName - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 325
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 326
OSVersion SystemFirmwareVersion SystemSerialNumber Property implementation GUID string generated at the time Device Alert) 303 Time of the event or time of the indication if event time unknown HP SAS Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 327
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 328
307 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system generating the indication CreationClassName the computer system generating the indication Platform GUID of the computer system generating the indication 14BSAS HBA 328 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 329
sensor status changed to Warning Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description Property implementation GUID string generated at the time of indication 3 (Warning) Time of indication A Storage Enclosure Temperature sensor - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 330
308 Time of the event or time of the indication if event time unknown HP SAS Ensure that the system is adequately ventilated. Check for proper room temperature and of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 331
to Critical Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat Property implementation GUID string generated at the time of indication 5 (major) Time of indication A Storage Enclosure - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 332
Time of the event or time of the indication if event time unknown HP SAS Ensure that the system is adequately ventilated. Check for proper room of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 333
Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID Property implementation GUID string generated at the time of indication 2 (Info) Time of indication A Storage Enclosure - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 334
the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 335
AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation GUID string generated at the time of indication 3 (Warning) Time of indication A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 336
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 337
Description AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation GUID string generated at the time of indication 5 (major ) 5 (Device Alert) 306 Time of the event or time of the indication if event time unknown HP SAS 14BSAS HBA 337 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 338
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 339
Table 15-88 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure Property name BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HP_HardwareIndication HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 340
.mof • HPWmiSCSIErrorMetaData.mof • HPWMISCSIEvent.mof • HPWMISCSIRegistration.mof 16-2 Use cases For use cases, see HP SCSI HBA Profile (P00123). 16-3 Class implementations The following sections define the supported properties for the SCSI HBA provider. For details of each property, see the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 341
) Key: HPSCSI_HBAComputerSystem Key: HBA index Other 0 (Not Dedicated) Direct Attached Storage HBA More info for OperationalStatus result(s) See HP SCSI HBA Profile 16-3-2 HPSCSI_StorageVolume HPSCSI_StorageVolume represents the volumes exposed to the host system. These volumes have a one-to-one - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 342
Table 16-3 Class: HPSCSI_StorageVolume (CIM_ StorageVolume) Property name Name CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_StorageExtent BlockSize ConsumableBlocks - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 343
Table 16-4 Class: HPSCSI_DiskDrive (CIM_DiskDrive) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name OperationalStatus[0] CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 344
16-3-4 HPSCSI_StorageExtent HPSCSI_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive. Table 16-5 Class: HPSCSI_StorageExtent (CIM_StorageExtent) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 345
Table 16-6 Class: HPSCSI_DiskDriveFirmwareIdentity (CIM_SoftwareIdentity) Property name ElementName CIM_ManagedSystemElement Name CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] Classifications[0] Description InstanceID Manufacturer IdentityInfoType IdentityInfoValue - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 346
Table 16-7 Class: HPSCSI_HBAPhysicalPackage (CIM_PhysicalPackage) Property name Version Property implementation N/A-Not available in this implementation. 16-3-7 HPSCSI_DiskPhysicalPackage HPSCSI_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 347
implementation Enclosure Serial Number Opaque key N/A - Not available in this implementation 2 (not applicable) See HP Storage Enclosure Profile 16-3-9 HPSCSI_StorageEnclosureProcessor HPSCSI_StorageEnclosureProcessor represents the management processor within a Storage Enclosure. This instance - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 348
status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows: • OperationalStatus[0]-Enclosure status ○ 0 (Unknown) ○ 2 (OK) ○ 3 (Degraded) ○ 6 (Error) • OperationalStatus - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 349
Table 16-11 Class: HPSCSI_HBAPortController (CIM_PortController) Property name CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_Controller CIM_PortController ControllerType OtherControllerType - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 350
Table 16-12 Class: HPSCSI_DAPort (CIM_DAPort) Property name CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort UsageRestriction CIM_DAPort HPSCSI_DAPort Property implementation HPSCSI_DAPort Opaque key HPSCSI_HBAComputerSystem HBA Index 2 (Front-End Only) 16-3-12 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 351
Table 16-13 Class: HPSCSI_SPIPort (CIM_SPIPort) Property name UsageRestriction CIM_SPIPort MaxDataWidth MaxTransferRate Property implementation 3 (Back-end Only) Max bus width (bits) Max rate in bits per second 16-3-13 HPSCSI_HBAFirmwareIdentity HPSCSI_HBAFirmwareIdentity represents the firmware - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 352
represents the monitoring and performance data counters on HP disk drives. Table 16-16 Class: SCSIID:0) Opaque key 0 See HP SCSI HBA Profile P00123. See HP SCSI HBA Profile P00123 See HP SCSI HBA Profile P00123 See HP SCSI HBA Profile P00123 See HP SCSI HBA Profile P00123 15BSCSI - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 353
implementation Serial number if known Opaque key N/A-Not available in this implementation 2 (Not Applicable) See HP Storage Enclosure profile See HP Storage Enclosure profile 16-3-17 HPSCSI_HBASCSIProtocolEndpoint HPSCSI_HBASCSIProtocolEndpoint represents an access point to storage resources for - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 354
Table 16-18 Class: HPSCSI_HBASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name ElementName CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault RequestedState CIM_ServiceAccessPoint CreationClassName Name SystemCreationClassName SystemName - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 355
Table 16-19 Class: HPSCSI_DASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Name SystemCreationClassName SystemName CIM_ProtocolEndpoint ProtocolIFType CIM_SCSIProtocolEndpoint ConnectionType Role Property implementation HBA Index HPSCSI_HBAComputerSystem HBA index 0 (Unknown) 3 ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 356
GroupStatusDescriptions Property implementation HP consolidated status for all SCSI HBAs Consolidated OperationalStatus for all HPSCSI_ComputerSystem instances HP consolidated status for all SCSI HBAs Opaque key Consolidated status for all SCSI HBAs • 0 (Other) • 2 ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 357
Table 16-22 Class: HPSCSI_StorageEnclsoureLocation (HP_Location) Property name Description Name PhysicalPosition ElementLocationTag ElementLocationTagDesc Property implementation Enclosure location For example, Internal Storage System on Port 1 Key Key • External for external enclosures • Internal - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 358
Table 16-24 Class: HPSCSI_HBALocation (HP_Location) Property name ElementName Caption Description Name PhysicalPosition ElementLocationTag ElementLocationTagDesc LocationInformation[0] LocationInfoDesc[0] Property implementation Controller name and location (for example, SCSI Controller Port 1 in - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 359
Table 16-26 Class: HPSCSI_HBAProduct (CIM_Product) Property name ElementName IdentifyingNumber Name Vendor Version Property implementation Controller name and location (for example, SCSI Controller Port 1 in Slot 4) Key: Opaque key Marketing name Vendor string Firmware version 16-3-26 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 360
16-3-29 HPSCSI_HBAComputerSystemDiskDrive (Association) Table 16-30 Class: HPSCSI_HBAComputerSystemDiskDrive (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSCSI_HBAComputerSystem HPSCSI_DiskDrive 16-3-30 HPSCSI_HBAComputerSystemStorageVolume (Association) - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 361
Table 16-34 Class: HPSCSI_HBAComputerSystemDAPort (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSCSI_HBAComputerSystem HPSCSI_DAPort. 16-3-34 HPSCSI_HBAComponentCS (Association) Table 16-35 Class: HPSCSI_HBAComponentCS (CIM_ComponentCS) Property name - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 362
16-3-38 HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackage (Association) Table 16-39 Class: HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackage (CIM_Container) Property name GroupComponent PartComponent Property implementation HPSCSI_HBAPhysicalPackage HPSCSI_DiskPhysicalPackage 16-3-39 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 363
16-3-42 HPSCSI_StorageEnclosureProcessorEnclosureFirmware (Association) Table 16-43 Class: HPSCSI_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSCSI_EnclosureFirmware - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 364
16-3-46 HPSCSI_StorageExtentStorageVolume (Association) Table 16-47 Class: HPSCSI_StorageExtentStorageVolume (CIM_BasedOn) Property name SystemElement SameElement Property implementation HPSCSI_StorageExtent HPSCSI_StorageVolume 16-3-47 HPSCSI_DAPortSCSIProtocolEndpoint (Association) Table 16- - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 365
Table 16-51 Class: HPSCSI_HBAGroupCollectionHBAComputerSystem (CIM_MemberOfCollection) Property name Member Collection Property implementation HPSCSI_ HBAComputerSystem HPSCSI_HBAGroupCollection 16-3-51 HPSCSI_HBASystemPackaging (Association) Table 16-52 Class: HPSCSI_HBASystemPackaging ( - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 366
16-3-55 HPSCSI_StorageEnclosureEnclosureLocation (Association) Table 16-56 Class: HPSCSI_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Element PhysicalLocation Property implementation HPSCSI_StorageEnclosure HPSCSI_StorageEnclosureLocation 16-3-56 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 367
Property implementation HPSCSI_HBAComputerSystem HPSCSI_DASCSIProtcolEndpoint 16-4 Supported indications Table 16-62 HPSCSI_DeviceIndication: SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Information - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 368
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 369
SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion Property implementation GUID string generated at indication Severity (for example, 5 (Major)) Time of indication SCSI physical - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 370
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 371
the computer system generating the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 15BSCSI HBA 371 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 372
CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName Property implementation GUID string generated at indication 6 (Critical) Time of indication The physical drive is offline - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 373
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 374
EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion Property implementation GUID string generated at indication 2 (Informational) Time of indication A physical drive that was - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 375
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 376
EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion SystemFirmwareVersion SystemSerialNumber SystemProductID SystemModel Property implementation GUID string generated at indication 2 (Information) Time of indication A physical drive that was - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 377
Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at indication 2 (Information) Time of indication A physical drive that was located - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 378
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 379
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 2 (Information) Time of indication A physical drive that was located - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 380
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 381
Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation GUID string generated at indication 0 (unknown) Time of indication Controller The SCSI device has - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 382
HWFirmwareVersion HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 383
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 384
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 6 (Critical) Time of indication SCSI HBA has failed and - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 385
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 386
HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion SystemFirmwareVersion SystemSerialNumber Property implementation GUID string generated at indication 5 (Major) Time of indication This SCSI Storage enclosure power - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 387
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 388
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 389
IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions Property implementation GUID string generated at indication 3 (Warning) Time of indication One of the component power - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 390
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 391
EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion Property implementation GUID string generated at indication 2 (Info) Time of indication The storage enclosure temperature is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 392
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 393
SystemSerialNumber SystemProductID Property implementation GUID string generated at indication HPSCSI_StorageEnclosureProcessor class instance 2 (CIMObjectPath) 5 (Device Alert) 24 SCSIHBA Ensure server cover is properly installed. Ensure all empty disk drive bays are filled with - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 394
HWFirmwareVersion HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 395
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 396
Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Storage enclosure fan subsystem is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 397
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 398
ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProviderVersion NetworkAddresses OSType OSVersion Property implementation GUID string generated at indication 4 (Minor) Time of indication This SCSI Storage enclosure fan is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 399
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 400
the computer system generating the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 15BSCSI HBA 400 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 401
Table 16-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name ImpactedDomain BladeBay * BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HP_HardwareIndication HWFirmwareVersion HWLogicalLocation HWManufacturer HWSerialNumber - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 402
implements the DMTF Software Inventory profile to support inventory of HP installed software on Integrity systems. The following profiles are implemented and -3 Class implementations The following classes are implemented for Integrity server platforms. The following classes describe software. 17-3-1 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 403
Table 17-2 Class: CIM_SoftwareIdentity Property name ElementName CIM_ManagedSystemElement OperationalStatus StatusDescriptions Name CIM_SoftwareIdentity InstanceID Classifications ClassificationDescriptions Manufacturer InstallDate Property implementation Contains the corresponding comma separated - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 404
Table 17-2 Class: CIM_SoftwareIdentity Property name VersionString MajorVersion MinorVersion RevisionNumber BuildNumber IdentityInfoType IdentityInfoValue Property implementation Version of the software identity as reported by its underlying instrumentation. If this version can be represented in - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 405
17-4 Supported indications There are no indications produced for the software inventory profile implementation. 16BSystem software 405 - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 406
registration 18-1 Overview The following profiles are implemented and files are installed by this provider. Table 18-1 Overview Implemented Profiles Provider Installation Files HP Profile Registration Profile (P00100) • HPWmiProfile.dll • HPWmiProfile.mof 18-2 Use cases For use cases, see the - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 407
Profile 1.0.0 Power State Management 1.0.0 Profile Software Inventory Profile 1.0.0 Physical Asset Profile 1.0.0 InstanceID Caption/Description/ ElementName CIM:Base Server DMTF Base Server Profile CIM:CPU DMTF CPU Profile CIM:Fan DMTF Fan Profile CIM:Power Supply DMTF Power Supply - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 408
Values of HP_RegisteredProfile for HP WBEM TC Profiles RegisteredName Registered Version InstanceID HP Base Server HP CPU HP Fan 1.0.0 1.0.0 1.0.0 HP:Base Server HP:CPU HP:Fan Caption/Description/ ElementName HP Base Server Profile HP CPU Profile HP Fan Profile 17BProfile registration - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 409
HP:Power Supply HP Power Supply Profile HP:Record Log HP Record Log Profile HP:Sensors HP Sensors Profile HP:Memory HP Memory Profile HP:Base Server Physical Asset HP Base Server Physical Asset Profile HP:CPU Physical Asset HP CPU Physical Asset Profile HP:Memory Physical Asset HP - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 410
HP_ReferencedProfile HP_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered in for server and network profiles, the storage computer system for storage profiles) 18-4 Supported indications There - HP Integrity Superdome SX1000 | HP Insight Management WBEM Providers on Integrit - Page 411
19 For more information • http://www.dmtf.org • http://www.snia.org • http://www.hp.com 18BFor more information 411
HP Insight Management WBEM Providers for
Windows on Integrity Servers
Data Sheet
Part number
5992-4515
First Edition September 2008