HP Integrity rx8620 Windows Integrity Management Agents Reference - Page 72

Uncorrectable PAA fault on MX2 Probable Cause: An uncorrectable PAA fault has

Page 72 highlights

Event ID Event Severity Event Description 10060 Warning The left cell latch is open. SNMP Trap: hpevtCellLatchOpen - 10060 in HPIFPTRAP.MIB. 10061 Warning Right ejector latch is open Probable Cause: The right ejector latch is open. Recommended Action: Close the right ejector latch on the specified cell. SNMP Trap: hpevtDcnfgRightCellLatch - 10061 in HPIFPTRAP.MIB. 10062 Warning The optical emitters on the cell latch sensors are not functioning Probable Cause: There is a hardware failure. Recommended Action: The cell board must be repaired or replaced. SNMP Trap: hpevtCellLatchSensorBad - 10062 in HPIFPTRAP.MIB. 10063 Warning The vrm on the specified cell is reporting a voltage fault. Probable Cause: The specified vrm is reporting a fault. Recommended Action: Replace the specified VRM. The datafield contains the physical location. Byte 16 is the cabinet, byte 13 is the cell slot, and byte 11 is the vrm slot. The vrm slot in byte 11 matches the vrm number silkscreened on the cell board. SNMP Trap: hpevtVrmVltFault - 10063 in HPIFPTRAP.MIB. 10064 Warning The vrm on the specified cell is reporting a temperature fault. SNMP Trap: hpevtVrmTempFlt - 10064 in HPIFPTRAP.MIB. 10065 Warning The rail on a cell is reporting a fault. SNMP Trap: hpevtVrmFlt - 10065 in HPIFPTRAP.MIB. 10068 Warning A I/O backplane vrm is reporting a voltage fault. SNMP Trap: hpevtVrmIoVltFlt 10068 in HPIFPTRAP.MIB. 10069 Warning A I/O backplane power brick is reporting a voltage fault. SNMP Trap: hpevtPwrBrickVltFlt - 10069 in HPIFPTRAP.MIB. 10070 Warning A I/O backplane vrm is reporting a temperature fault. SNMP Trap: hpevtVrmBkPlaneTempFlt - 10070 in HPIFPTRAP.MIB. 10071 Warning A I/O backplane power brick is reporting a temperature fault. SNMP Trap: hpevtBkPlanePwrBrickTempFlt - 10071 in HPIFPTRAP.MIB. 10072 Warning A I/O backplane vrm rail is reporting a fault. SNMP Trap: hpevtBkPlanVrmRailFlt - 10072 in HPIFPTRAP.MIB. 10073 Warning A I/O backplane power brick is reporting a rail fault. SNMP Trap: hpevtBkPlanePwrBrkFlt - 10073 in HPIFPTRAP.MIB. 10103 Warning The specified system backplane vrm is reporting a module voltage fault. SNMP Trap: hpevtBkPlaneVrmVltFlt - 10103 in HPIFPTRAP.MIB. 10104 Warning The specified system backplane vrm is reporting a temperature fault. SNMP Trap: hpevtBkPlaneVrmTempFlt - 10104 in HPIFPTRAP.MIB. 10105 Warning The specified system backplane rail is reporting a fault SNMP Trap: hpevtBkPlaneFlt - 10105 in HPIFPTRAP.MIB. 10115 Warning Master MP failure. Slave MP has taken control SNMP Trap: hpevtMstrMpFailed 10115 in HPIFPTRAP.MIB. 10116 Error The NVRAM service was unable to satisfy an NVRAM allocation request Probable Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear NVRAM and reset. SNMP Trap: hpevtNvramAlloc - 10116 in HPIFPTRAP.MIB. 10132 Error The RTC not updating its internal time registers Probable Cause: Bad RTC chip on the PDH daughtercard. Recommended Action: Replace PDH daughtercard SNMP Trap: hpevtRtcTimeReg - 10132 in HPIFPTRAP.MIB. 10159 Warning Uncorrectable PAA fault on MX2 Probable Cause: An uncorrectable PAA fault has occurred on the MX2 module and PAA firmware has halted. Recommended Action: Contact your HP support personnel. SNMP Trap: hpevtPAAFltMx2 - 10159 in HPIFPTRAP.MIB. 72 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

Event Description
Event Severity
Event ID
The left cell latch is open. SNMP Trap: hpevtCellLatchOpen - 10060 in
HPIFPTRAP.MIB.
Warning
10060
Right ejector latch is open Probable Cause: The right ejector latch is open.
Recommended Action: Close the right ejector latch on the specified cell. SNMP Trap:
hpevtDcnfgRightCellLatch - 10061 in HPIFPTRAP.MIB.
Warning
10061
The optical emitters on the cell latch sensors are not functioning Probable Cause:
There is a hardware failure. Recommended Action: The cell board must be repaired
or replaced. SNMP Trap: hpevtCellLatchSensorBad - 10062 in HPIFPTRAP.MIB.
Warning
10062
The vrm on the specified cell is reporting a voltage fault. Probable Cause: The specified
vrm is reporting a fault. Recommended Action: Replace the specified VRM. The
datafield contains the physical location. Byte 16 is the cabinet, byte 13 is the cell slot,
and byte 11 is the vrm slot. The vrm slot in byte 11 matches the vrm number
silkscreened on the cell board. SNMP Trap: hpevtVrmVltFault - 10063 in
HPIFPTRAP.MIB.
Warning
10063
The vrm on the specified cell is reporting a temperature fault. SNMP Trap:
hpevtVrmTempFlt - 10064 in HPIFPTRAP.MIB.
Warning
10064
The rail on a cell is reporting a fault. SNMP Trap: hpevtVrmFlt - 10065 in
HPIFPTRAP.MIB.
Warning
10065
A I/O backplane vrm is reporting a voltage fault. SNMP Trap: hpevtVrmIoVltFlt -
10068 in HPIFPTRAP.MIB.
Warning
10068
A I/O backplane power brick is reporting a voltage fault. SNMP Trap:
hpevtPwrBrickVltFlt - 10069 in HPIFPTRAP.MIB.
Warning
10069
A I/O backplane vrm is reporting a temperature fault. SNMP Trap:
hpevtVrmBkPlaneTempFlt - 10070 in HPIFPTRAP.MIB.
Warning
10070
A I/O backplane power brick is reporting a temperature fault. SNMP Trap:
hpevtBkPlanePwrBrickTempFlt - 10071 in HPIFPTRAP.MIB.
Warning
10071
A I/O backplane vrm rail is reporting a fault. SNMP Trap: hpevtBkPlanVrmRailFlt
- 10072 in HPIFPTRAP.MIB.
Warning
10072
A I/O backplane power brick is reporting a rail fault. SNMP Trap:
hpevtBkPlanePwrBrkFlt - 10073 in HPIFPTRAP.MIB.
Warning
10073
The specified system backplane vrm is reporting a module voltage fault. SNMP Trap:
hpevtBkPlaneVrmVltFlt - 10103 in HPIFPTRAP.MIB.
Warning
10103
The specified system backplane vrm is reporting a temperature fault. SNMP Trap:
hpevtBkPlaneVrmTempFlt - 10104 in HPIFPTRAP.MIB.
Warning
10104
The specified system backplane rail is reporting a fault SNMP Trap: hpevtBkPlaneFlt
- 10105 in HPIFPTRAP.MIB.
Warning
10105
Master MP failure. Slave MP has taken control SNMP Trap: hpevtMstrMpFailed -
10115 in HPIFPTRAP.MIB.
Warning
10115
The NVRAM service was unable to satisfy an NVRAM allocation request Probable
Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear
NVRAM and reset. SNMP Trap: hpevtNvramAlloc - 10116 in HPIFPTRAP.MIB.
Error
10116
The RTC not updating its internal time registers Probable Cause: Bad RTC chip on
the PDH daughtercard. Recommended Action: Replace PDH daughtercard SNMP
Trap: hpevtRtcTimeReg - 10132 in HPIFPTRAP.MIB.
Error
10132
Uncorrectable PAA fault on MX2 Probable Cause: An uncorrectable PAA fault has
occurred on the MX2 module and PAA firmware has halted. Recommended Action:
Contact your HP support personnel. SNMP Trap: hpevtPAAFltMx2 - 10159 in
HPIFPTRAP.MIB.
Warning
10159
72
Management Agents Event Tables