HP LC2000r Pedestal-to-Rack Conversion Guide - Page 36

Install Chassis Retention Bracket when Shipping an HP Rack

Page 36 highlights

Chapter 3 Conversion: Install Components, Cover, and Front Bezel Install Chassis Retention Bracket when Shipping an HP Rack For the HP rack, the rack nuts for the chassis retention bracket were installed on the right rear rack column. For the HP rack, install the chassis retention bracket and secure the NetServer to it, as follows: 1. Position the bracket as shown in Figure 3-9. Right Rear Column of HP Rack Hole 13 above Base Line Rack Nuts Hole 9 above Base Line Chassis Retention Bracket Figure 3-9. Screw Bracket to Rack and NetServer (Shown for HP NetServer LH 3r; Number of Power Supply Modules May Vary) NOTE The Chassis Retention Bracket is only required for shipping the system in an HP rack. 2. Fasten the bracket to the rack with the two 10x32 screws. 3. Fasten the bracket to the NetServer with the two 6x32 screws. For the HP rack with an anti-tip foot, retract the anti-tip foot if other components will not be extended from the front of the rack. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Chapter 3
Conversion: Install Components, Cover, and Front Bezel
32
Install Chassis Retention Bracket when Shipping
an HP Rack
For the HP rack, the rack nuts for the chassis retention bracket were installed on
the right rear rack column.
For the HP rack, install the chassis retention bracket and secure the NetServer to
it, as follows:
1.
Position the bracket as shown in Figure 3-9.
Chassis Retention
Bracket
Rack Nuts
Right Rear Column
of HP Rack
Hole 13 above Base Line
Hole 9 above Base Line
Figure 3-9. Screw Bracket to Rack and NetServer (Shown for HP NetServer
LH 3r; Number of Power Supply Modules May Vary)
NOTE
The Chassis Retention Bracket is only required for shipping the
system in an HP rack.
2.
Fasten the bracket to the rack with the two 10x32 screws.
3.
Fasten the bracket to the NetServer with the two 6x32 screws.
For the HP rack with an anti-tip foot, retract the anti-tip foot if other components
will not be extended from the front of the rack.