Table 14, Description, Dimensions H x W x D

Page 95 highlights

Table 14 Physical Dimensions Item System board platform System board dimension Server dimensions Rack Server weight Description ATX (Advanced Technology Extended) 12'' x 13.5'' 448W * 43H * 698.7D (mm) Basic Configuration ( excludes keyboard and monitor): 19 kg Table 15 Environmental Specifications Item Temperature: Operating Non-operating Storage Wet-bulb temperature Relative humidity: Operating Non-operating Storage Altitude: Operating Non-operating Thermal output (maximum operating) Acoustic emissions Normal configuration Description +10 to +35° (+50 to +95°F) -30 to 60° (-22 to 140°F) -30 to 60° (-22 to 140°F) 38.7° (101.7°F) 10% to 90% (non-condensing) 5% to 95% 5% to 95% 0 to 3049 meters (0 to 10,000 ft) 0 to 9146 meters (0 to 30,000 ft) 392 W/hr c LWad: 6.7 Bels (operating at room temperature) LWad: 6.7 Bels (Idle at room temperature) Table 16 Non-Hot-Plug Power Supply Specifications Item Dimensions (H x W x D) Weight (approximate) Input requirements: Rated input voltage Normal line voltage Line frequency Rated input current BTU rating Description 40 mm x 106 mm x 270 mm 1.85 kg 90 VAC to 264 VAC 100 VAC to 120 VAC /200 VAC to 240 VAC 50 - 60 Hz 5.5 -10 A N/A Physical and operating specifications 95

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Physical and operating specifications
95
Table 14
Physical Dimensions
Item
Description
System board platform
ATX (Advanced Technology Extended)
System board dimension
12’’ x 13.5’’
Server dimensions
Rack
448W * 43H * 698.7D (mm)
Server weight
Basic Configuration ( excludes keyboard and monitor): 19 kg
Table 15
Environmental Specifications
Item
Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35° (+50 to +95°F)
-30 to 60° (-22 to 140°F)
-30 to 60° (-22 to 140°F)
38.7° (101.7°F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr c
LWad: 6.
7
Bels
(operating at room temperature)
LWad:
6.7
Bels
(Idle at room temperature)
Table 16
Non-Hot-Plug Power Supply Specifications
Item
Description
Dimensions (H x W x D)
40 mm x 106 mm x 270 mm
Weight (approximate)
1.85 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC /200 VAC to 240 VAC
Line frequency
50 – 60 Hz
Rated input current
5.5 –10 A
BTU rating
N/A