HP StorageWorks 2/16 HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May
HP StorageWorks 2/16 - SAN Switch Manual
View all HP StorageWorks 2/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/16 manual content summary:
- HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 1
Installation Guide hp StorageWorks SAN Switch 2/16 Version 3.1.2 Fourth Edition (May 2004) Part Number: AA-RR84D-TE This installation guide provides basic procedures for setting up, configuring, and managing the SAN Switch 2/16 and SAN Switch 2/16 power pack models. - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 2
are set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A. SAN Switch 2/16 Version 3.1.2 Installation Guide Fourth Edition (April 2004) Part Number: AA-RR84D-TE - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 3
this Guide 7 Audience 8 Related Documentation 8 Conventions 8 Document Conventions 9 Text Symbols 9 Equipment Symbols 10 Rack Stability 11 Getting Help 11 HP Technical Support 11 HP Storage Website 12 HP Authorized Reseller 12 1 Overview 13 SAN Switch 2/16 Features 14 Firmware 14 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 4
Telnet 61 Logging in to the Switch 61 Changing the Admin Password and User ID 62 Configuring the IP and Fibre Channel Address 63 Displaying Devices within the Fabric 63 Checking the Firmware Version 64 Setting the Switch Date and Time 64 4 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 5
Restoring the System Configuration Settings 69 Upgrading or Restoring the Switch Firmware 69 Downloading Firmware from the HP Website 70 A Regulatory Compliance Notices 71 FCC EMC Statement 83 Glossary 85 Index 97 Figures 1 SFP media side 16 SAN Switch 2/16 Version 3.1.2 Installation Guide 5 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 6
HP System/e cabinet 32 9 Assembling the inner rails 33 10 Assembling the inner rails on a SAN Switch with plenum 34 11 Installing the switch into a rack (HP 10000 series or comparable EIA cabinet 35 12 Installing the switch into a rack (HP 83 6 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 7
This installation guAidbe porouvitdetshinisforGmautioindtoehelp you set up and configure the HP StorageWorks SAN Switch 2/16. This preface discusses the following topics: About this Guide ■ Audience, page 8 ■ Related Documentation, page 8 ■ Conventions, page 8 ■ Rack Stability, page 11 ■ Getting - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 8
2000®, Windows NT®, and IBM AIX ■ Web Tools Graphical User Interface (GUI), for configuring the switch via a supported Web browser Related Documentation For a list of related documents included with this product, see the Related Documents section of the HP StorageWorks SAN Switch 2/16 Version - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 9
italic font> Blue, underlined sans serif font text, for example: http://www.hp.com Text Symbols The following symbols may be found in the text of this guide. WARNING: Text set commentary, sidelights, or interesting points of information. SAN Switch 2/16 Version 3.1.2 Installation Guide 9 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 10
: To reduce the risk of personal injury from electrical shock, remove all power cords to completely disconnect power from the power supplies and systems. 10 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 11
manually HP authorized service provider or go to our website at: http://www.hp.com. HP Technical Support In North America, call technical support at 1-800-652-6672, available 24 hours a day, 7 days a week. Note: For continuous quality improvement, calls may be recorded or monitored. SAN Switch 2/16 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 12
. HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518. ■ In Canada, call 1-800-263-5868. ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com 12 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 13
HP StorageWorks SAN Switch 2/16 is offered in two configurations: the 2/16 and 2/16 power pack. Refer to the HP StorageWorks SAN Switch 2/16 Fabric OS 3.1.2 Release Notes for a complete list of management features enabled on your switch. Note: This guide refers to both models as the SAN Switch 2/16 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 14
within a fabric. For more information refer to the HP StorageWorks Zoning Version 3.1.x/4.1.x User Guide. ■ Per port statistics to help technicians diagnose and isolate problem ports without disrupting switch operations. ■ Error detection and fault isolation, which automatically disables failing - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 15
chassis, and an embedded processor that processes frames up to 1024 bytes. ■ A real-time clock (RTC) with a 10-year battery and 56 bytes of NVRAM. SAN Switch 2/16 Version 3.1.2 Installation Guide 15 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 16
SAN Switch 2/16 to link or cascade to other HP StorageWorks Fibre Channel switches running v2.6x and later, building a highly scalable SAN fabric. The Fibre Channel SAN Switch 2/16 supports , FC-PI specification for Fibre Channel SFP transceivers. 16 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 17
the combined bandwidth of up to four ISLs between two directly adjacent switches, while preserving in-order delivery. For specific information about ISL trunking, refer to the HP StorageWorks Trunking Version 3.1.x/4.1.x User Guide. SFPs The ports connect to SFP media. SFPs are universal and self - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 18
Hardware Kits HP provides the following optional hardware kits in support of the SAN Switch 2/16, see Table 2. Table 2: SAN Switch 2/16 Orderable Hardware -B27** C7534A* C7534A* * Pre-merger HP part number ** Pre-merger Compaq part number 18 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 19
on Setting the Core PID Format, page 44 ■ Modifying Domain IDs, page 46 ■ Specifying Custom Status Policies, page 47 ■ Connecting the Switch to the Fabric, page 47 ■ Installing Multiple Switches into an Existing SAN, page 49 ■ Next Steps, page 50 SAN Switch 2/16 Version 3.1.2 Installation Guide 19 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 20
Unpack the shipping cartons. Note: The Rack Mount Kit shown in Figure 3 and Table 3 may not represent the kit that shipped with your switch. HP reserves the right to substitute Rack Mount Kits, providing applicable instructions with each switch. 20 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 21
2 1 4 6 Figure 3: Carton contents Installing the SAN Switch 2/16 3 5 SHR-2489B SAN Switch 2/16 Version 3.1.2 Installation Guide 21 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 22
the end of the cable) 4 HP StorageWorks SAN Switch 2/16 5 SAN Switch Rack Mount Kit (PN 331148-B21): SAN Switch 2/32 • (14) 8-32 x 5/16-inch Phillips pan-head SEMS screw for use with the SAN Switch 2/8, SAN Switch 2/8V, SAN Switch 2/16, SAN Switch 2/16V, and SAN Switch 2/16N Note: 8-32 x 5/16 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 23
SAN Switch 2/16 in one of the following ways: ■ As a stand-alone unit on a flat surface. For instructions, see Installing the SAN Switch as a Stand-alone Unit, page 25. ■ In the HP 9000 Series (or comparable) Rack using the SAN Switch Rack Mount Kit supplied with the switch into the switch chassis by - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 24
them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. 24 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 25
supply, repeat steps 3 through 4 for the second power supply. Note: Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see "Configuring Network Addressing" on page 39. SAN Switch 2/16 Version 3.1.2 Installation Guide 25 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 26
the SAN Switch 2/16 Installing the Switch in a Rack Using the SAN Switch Rack Mount Kit This section provides instructions for installing the switch in an HP System/e cabinet, or in an HP 10000 series cabinet using the HP StorageWorks SAN Switch Rack Mount Kit supplied with your switch. The - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 27
graphic is not available for this release. (10) #10-32 x 1/2-inch Phillips pan-head screw with captive star lock washer (8) #10 alignment washer (8) #10 adapter washer (2) 1/4-20 hex nut with captive star lock washer (2) 1/4-inch flat washer SAN Switch 2/16 Version 3.1.2 Installation Guide 27 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 28
of the two brackets with two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 adapter washers as shown in Figure 4. Figure 4: Installing the rear mounting brackets (HP 10000 series or comparable EIA cabinet) 28 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 29
Installing the SAN Switch 2/16 - For an HP System/e rack, install each of the two rear mounting brackets with two #10-32 x 1/2-inch Phillips pan-head screws and two #10 alignment washers as shown in Figure 5. Figure 5: Installing the rear mounting brackets (HP System/e rack-left rear upright) Note: - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 30
Installing the SAN Switch 2/16 a. Attach the left outer rail and the right outer rails to the rear mounting ; they will be tightened later in step 8 on page 36. Figure 6: Installing the outer rails (HP 10000 series or comparable EIA cabinet) 30 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 31
-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 7. Figure 7: Assembling the outer rails (HP 10000 series or comparable EIA cabinet) SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 32
the upper and lower hole locations of the left rail. See Figure 8. Figure 8: Assembling the outer rails (HP System/e cabinet) Caution: Do not use screws other than those provided. Use of any longer screws can cause damage to internal components. 32 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 33
Note: The mounting holes in the inner rails are marked 32, 16, and 8. When mounting the SAN Switch 2/16, use the mounting holes labelled 16 to install the inner rails on the switch. When viewing a rack from the front, the left rails are used on the left side of the rack and the right rails are used - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 34
Installing the SAN Switch 2/16 Note: For factory integration only, tighten the #8-32 x 5/16-inch Phillips pan-head screw with thread lock and torque between 6 to 8 inch-pounds. Note: The plenum is a required part of this installation when the SAN switch 2/16 is installed in an HP 9000 or 10000 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 35
the switch into a rack (HP 10000 series or comparable EIA cabinet) 7. Insert the switch into the rack and install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers, one on each side. See Figure 11 and Figure 12. SAN Switch 2/16 Version 3.1.2 Installation Guide 35 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 36
Installing the SAN Switch 2/16 Figure 12: Installing the switch into a rack (HP System/e cabinet) 8. Tighten the nuts installed in step a of step 4 on page 30. See Figure 6 on page 30. Note: To uninstall a switch, remove the middle #10-32 x 1/2-inch Phillips pan head screw with captive star lock - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 37
indicates power off). The switch automatically runs POST. Caution: Do not connect the switch to the network until the IP address is correctly set. For instructions on setting the IP address, see "Configuring Network Addressing," on page 39. SAN Switch 2/16 Version 3.1.2 Installation Guide 37 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 38
POST via LED activity, the error log, or Command Line Interface (CLI) using the errShow command. For more information about error messages, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide. 38 SAN Switch 2/16 Version 3.1.2 Installation - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 39
Serial communication software (for example, ProComm Plus or HyperTerminal) ■ Ethernet cable for connecting the switch to the workstation or to a network containing the workstation ■ SFPs and cables, as required to connect the switch to the fabric SAN Switch 2/16 Version 3.1.2 Installation Guide 39 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 40
the SAN Switch 2/16 Setting Network Addresses via a Serial Connection Use the following procedure to verify or change the switch IP address to use the RJ-45 connector to create a Serial connection. 4. Verify that the switch power is on and POST is completed. See the "Power-On Self Test" on - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 41
Installing the SAN Switch 2/16 Note: These steps show instructions specific to in to the switch (with administrator privileges). The default administrator logon is admin and the default password is password. a. Enter reboot]: Enter y to set now. SAN Switch 2/16 Version 3.1.2 Installation Guide 41 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 42
for use during the initial setting of the IP address and for service purposes. HP does not recomment using the serial port during normal switch operation or for regular maintenance. 8. Record the IP address on the label affixed to the switch. 42 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 43
. Verify that the switch is not accessed from any other connections during the remaining steps. 4. Log in to the switch with administrator privileges by Telnet. The default administrator logon is admin and the default password is password. SAN Switch 2/16 Version 3.1.2 Installation Guide 43 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 44
edge and the Core Switch 2/64 reside, you must verify that the edge switch (for example, SAN Switch 2/16) Core PID format matches the Core switch's PID format (always 1), before connecting to the SAN. If a switch is introduced to an existing SAN . 44 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 45
for instructions on connecting Fibre Channel cables. 9. If necessary, issue the cfgEnable command to reestablish zoning. Note: After the switch PID format is set, it is stored in the flash memory of the switch; it is not necessary to set it again during subsequent firmware upgrades. SAN Switch 2/16 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 46
SAN Switch 2/16 Modifying Domain IDs As an option, modify the domain IDs, if desired, as follows. Note: The default domain ID is 1. If the default domain ID is already in use when the switch is connected to the fabric, the domain ID for the new switch is automatically reset the previous switch, if - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 47
Installing the SAN Switch 2/16 Specifying Custom Status Policies As an option, if switch ports as required. Note: The ports and cables used in trunking groups must meet specific requirements. For a list of these requirements, refer to the HP StorageWorks ISL Trunking Version 3.1.x/4.1.x User Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 48
to verify that the switch is running properly. 1. Access your browser. 2. At the URL address window, enter: http://your switch IP address 3. If connected properly, the name of your switch appears (in green) at the prompt, indicating Healthy/OK. 48 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 49
Installing the SAN Switch 2/16 Note: HP strongly recommends that you back up the configuration. This ensures that a complete configuration is available if required for a replacement switch. For instructions on how to back up the configuration, refer to "Backing Up System Configuration Settings" in - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 50
the SAN Switch 2/16 4. Set the switch Domain Address (by issuing the configure command) to the next unused domain in the SAN. The default domain setting is 1. Note: If a switch boot failure occurs, the switch must be taken offline for repair or replacement. Contact your HP Technical Support for - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 51
the SAN Switch 2/16 device. Check the configuration information for your network components for specific requirements. See the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures User Guide for a detailed command description. Cascading Switches The Domain ID number uniquely identifies a switch - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 52
Installing the SAN Switch 2/16 52 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 53
Managing the SAN Switch 2/16 3 This chapter discusses the following topics: ■ Interpreting LED Activity, page 54 ■ Management Overview, page 60 ■ Running Basic Switch Operations Using Telnet, page 61 ■ Diagnostic Tests, page 65 SAN Switch 2/16 Version 3.1.2 Installation Guide 53 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 54
does not indicate a problem. Note: Any errors related to LED activity are listed in the error log. For information about the error log, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures Guide. Front Panel LEDs The front panel includes the following LEDs: ■ One Switch Power LED on - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 55
Managing the SAN Switch 2/16 Table 5: Front Panel LED Patterns During Normal Operation LED Port Status LED LED to port. No action required. No action required. No action required. No action required. Reset the switch from a management station. SAN Switch 2/16 Version 3.1.2 Installation Guide 55 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 56
. The port is transmitting/ receiving at 1 Gbps. The port is transmitting/ receiving at 2 Gbps. Recommended Action Reset the switch from a management station. Reset the port from a management station. No action required. No action required. 56 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 57
boot has had time to complete. If there is still no light, contact the switch supplier. No action required. Errors may be listed in the error log. Refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures Guide for more information. SAN Switch 2/16 Version 3.1.2 Installation Guide 57 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 58
failed. Recommended Action Verify power supply is on and power cable is connected to a valid power source. No action required. Verify that the switch is on and boot had time to complete. If there is still no light, contact the switch supplier. 58 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 59
. If no diagnostic tests are running, check the Port Status LEDs for fault indicators. Errors may be listed in the error log. Refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Procedures Guide for more information. SAN Switch 2/16 Version 3.1.2 Installation Guide 59 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 60
advantage of being virtually in front of any fabric, switch, or port. For more information refer to the HP StorageWorks Web Tools Version 3.1.x/4.1.x User Guide. Optional Management Features Refer to the HP StorageWorks SAN Switch 2/16 Version 3.1.x Release Notes for a complete list of management - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 61
switch must be connected to your IP network through the RS-232 port to enable connection through telnet. 2. At the login prompt, enter the user ID you are logging in as. For example: login: admin The password prompt is displayed if the user exists. SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 62
Managing the SAN Switch 2/16 3. Enter the password for the user: password: xxxxxx The default password is password. 4. If the login is successful, a prompt displays showing the switch name and user ID you are logged in as. For example: switch55>admin: Changing the Admin Password and User ID Use - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 63
SAN Switch 2/16 is shipped with a default IP address of 10.77.77.77. Use these steps to change the default IP address and configure the Fibre Channel IP address of the switch. 1. Log in to the switch as the admin user is then committed to the switch firmware. 8. You are then prompted - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 64
Switch Configuration Settings Follow these steps to display the system configuration settings. 1. Log in to the switch as the admin user. 2. At the command line, issue the configShow command. The system configuration settings are displayed. 64 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 65
about error messages, refer to the HP StorageWorks Fabric OS Procedures Version 3.1.x/4.1.x User Guide. Diagnostic Tests Diagnostic tests are provided to help troubleshoot the hardware and the firmware. The diagnostic tests provided on the switch include tests of internal connections and circuitry - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 66
Managing the SAN Switch 2/16 66 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 67
Configuration and Upgrading Firmware 4 This chapter discusses the following topics: ■ Backing Up System Configuration Settings, page 68 ■ Upgrading or Restoring the Switch Firmware, page 69 ■ Downloading Firmware from the HP Website, page 70 SAN Switch 2/16 Version 3.1.2 Installation Guide 67 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 68
system prompts you for each parameter, as follows: switch:admin> configupload Server Name or IP Address [host]: 123.45.678.901 User Name [user]: kelev File Name [config.txt]: switch1 Protocol (RSHD or FTP) [rshd]: ftp Password: upload complete 68 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 69
) or the FTP service (on a Windows or UNIX machine) is running on the host workstation. 2. Log in to the switch as the admin user. 3. At the command line, issue the following command: firmwareDownload hostIPaddr, user, path_filename, password SAN Switch 2/16 Version 3.1.2 Installation Guide 69 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 70
by issuing the fastBoot command. Downloading Firmware from the HP Website To download the firmware from the HP website, go to http://www.hp.com. The website contains the required loaders and instructions for downloading the firmware to a switch. 70 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 71
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment which case the FCC could void the user's authority to operate the equipment. SAN Switch 2/16 Version 3.1.2 Installation Guide 71 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 72
product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. Spécification ATI Classe A (France) DECLARATION D' 7779:1999 (Typprüfung) VCCI EMC Statement (Japan) 72 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 73
Harmonics Conformance (Japan) BSMI EMC Statement (Taiwan) Regulatory Compliance Notices RRL EMC Statement (Korea) SAN Switch 2/16 Version 3.1.2 Installation Guide 73 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 74
as a Class 1 Laser product, conforming to the requirements contained in Department Of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. The certification is indicated by a label on the metal established by the IEC and U.S. DHHS. 74 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 75
replacement or proper disposal, contact your HP authorized reseller or your authorized service provider. WARNING: Your switch contains an internal lithium manganese dioxide system or return them to HP, your authorized HP partners, or their agents. SAN Switch 2/16 Version 3.1.2 Installation Guide 75 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 76
Regulatory Compliance Notices 76 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 77
removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. SAN Switch 2/16 Version 3.1.2 Installation Guide 77 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 78
conductive field service tools. ■ Use a portable field service kit with HP authorized reseller install the part. Note: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 78 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 79
Technical Specifications This appendix discusses the following topics: ■ Dimensions, page 80 ■ Power Supply Specifications, page 81 ■ Environmental Requirements, page 82 ■ Memory Specifications, page 83 C SAN Switch 2/16 Version 3.1.2 Installation Guide 79 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 80
Switch 2/16 dimensions. Table 7: Physical Specifications Height Dimension Depth Width Weight (with both power supplies) Value 1.72 +/- 0.01 inches (4.37 +/- 0.03 cm) 24.5 +/- 0.03 inches (62.2 +/- 0.1cm) 17 inches (43.2 cm) 28.0 lbs (12.7 kg) 80 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 81
power supply is universal and capable of functioning worldwide without using voltage jumpers or switches. It meets IEC 61000-4-5 surge voltage requirements. The power supply has its 300 µsec - hot/cold start Fused in both hot & neutral lines . SAN Switch 2/16 Version 3.1.2 Installation Guide 81 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 82
the environmental ranges that are acceptable when the switch is operating, and the acceptable ranges when the switch is not operating. .Table 9: Environmental Requirements sq.wave 5G, 0-3 kHz at 1.0 octave/minute 10G, 0-5kHz at 1.0 octave/minute 82 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 83
switch utilizes the following memory. ■ Main Memory (SDRAM): 32 MB per switch ■ Flash Memory: Dual 8 MB ■ Boot Flash: 512K bytes of 8-bit for system boot The centralized memory maximizes the overall switch 2, 3, and 5 are supported; if pin 7 is used SAN Switch 2/16 Version 3.1.2 Installation Guide 83 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 84
Technical Specifications 84 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 85
to interface with a set of services. Arbitrated Loop A shared 100 MBps or 200 MBps Fibre Channel transport structured as a loop. Can support up to 126 devices and one an arbitrating L_Port waits for a response before beginning loop initialization. SAN Switch 2/16 Version 3.1.2 Installation Guide 85 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 86
is seven. See also Fabric, ISL. Chassis The metal frame in which the switch and switch components are mounted. Circuit An established communication path between two ports. Consists of two such as through telnet or SNMP, and does not involve a GUI. 86 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 87
; the number of receive buffers allocated by a recipient port to an originating port. Used by Class 1 and 2 services to manage the exchange of frames across the fabric between source and destination. See also End-to-end Flow Control, BB_Credit. SAN Switch 2/16 Version 3.1.2 Installation Guide 87 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 88
Protocol; mapping of protocols onto the Fibre Channel standard protocols. For example, SCSI FCP maps SCSI-3 onto Fibre Channel. Fibre Channel Transport A protocol service that supports communication between Fibre Channel service providers. 88 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 89
Channel. Set the gateway address on one switch to the Fibre Channel IP address of another switch to enable the other switch to forward IP traffic to the Ethernet port on the second switch. Gbps Gigabits per second (1,062,500,000 bits/second). SAN Switch 2/16 Version 3.1.2 Installation Guide 89 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 90
required to transmit a frame, from the time it is sent until it arrives. Link Services A protocol for link-related actions. Link As applies to Fibre Channel, a physical connection between two ports, consisting of both transmit and receive fibers. 90 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 91
Initialization Primitive; the signal used to begin initialization in a loop. Indicates either loop failure or resetting of a node. Looplet A set of devices connected in a loop to a port that is the open originator, and then enters the Open state. SAN Switch 2/16 Version 3.1.2 Installation Guide 91 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 92
Power On Self-Test; a series of tests run by a switch after it is turned on. Private Device A device that supports arbitrated loop protocol and can interpret 8-bit addresses, but cannot and can communicate with either private or public NL_Ports. 92 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 93
can log into the fabric and support 20-bit addresses (or has 20-bit phantom addresses created for it by the switch). Public Loop An arbitrated loop that direction between two N_Ports. Service Rate The rate at which an entity can service requests. SAN Switch 2/16 Version 3.1.2 Installation Guide 93 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 94
be accessed by an L_Port in the Open state. Translative Mode A mode in which private devices can communicate with public devices across the fabric. 94 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 95
when it is not connected or has not yet assumed a specific function in the fabric. UDP User Datagram Protocol; a protocol that runs on top of IP and provides port multiplexing for upper-level the XMITTED CLOSE state cannot attempt to arbitrate. SAN Switch 2/16 Version 3.1.2 Installation Guide 95 - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 96
partitioning of the fabric into logical groupings of devices. Devices in a zone can only access and be accessed by devices in the same zone. 96 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 97
carton contents checklist 22 cascading switches 51 changing switch password 62 changing the admin password 62 changing the admin user ID 62 checking results 38 command line, managing by 60 configuration settings 69 configuring SAN Switch 2/16 Version 3.1.2 Installation Guide Index Index domain ID - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 98
addressing 39 NVRAM 15 O optical ports LEDs 54 P physical dimensions of switch 80 port ethernet port 15 LED for port speed 54 LED for port status 54 serial port 15 speed 16 POST 38 power maximum capability 24 requirements 24 Power On Self-Test 49 SAN Switch 2/16 Version 3.1.2 Installation Guide - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 99
IP address 42 setting the switch date and time 64 SFPs 47 SAN Switch 2/16 Version 3.1.2 Installation Guide Index SNMP 60 SNMP, support, HP 11 telnet 61 managing by 60 temperature, requirements 82 tests, diagnostic 65 text symbols 9 thermometers 15 U upgrading or restoring the switch firmware - HP StorageWorks 2/16 | HP StorageWorks SAN Switch 2/16 V3.1.2 (AA-RR84D-TE, May - Page 100
Index Z zoning summary 14 100 SAN Switch 2/16 Version 3.1.2 Installation Guide
Installation
Guide
hp
StorageWorks
SAN Switch 2/16
Version 3.1.2
Fourth Edition (May 2004)
Part Number:
AA-RR84D-TE
This installation guide provides basic procedures for setting up, configuring, and managing the
SAN Switch 2/16 and SAN Switch 2/16 power pack models.