HP StorageWorks 2/16V HP StorageWorks Fabric OS 5.3.0b Release Notes (AA-RWEYF - Page 11

The FC4-48 Blade supports only core PID fmt 1 in Secure Fabric OS. - transformer

Page 11 highlights

FC4-48 port Blade for the 4/256 SAN Director FC4-16IP iSCSI Blade for the 4/256 SAN Director (continued) • The HP StorageWorks 4/48 SAN Director Blade requires a minimum of Fabric OS 5.2.0a. Do not insert the FC4-48 Blade into the 4/256 chassis until the chassis is running Fabric OS 5.2.0a or later. After Fabric OS has been updated and an FC4-48 has been installed, the Fabric OS will not be able to be downgraded earlier than 5.2.0a until the FC4-48 is removed. • The FC4-48 Blade supports only core PID (fmt 1) in Secure Fabric OS. • NPIV is supported only in ports 0 to 15 of the FC4-48 Blade. • Regarding long distance buffer credits, the FC4-48 has 560 credits available for long distance. The FC4-32 Blade has 624 credits available for long distance. • Regarding port mirroring, the FC4-48 is restricted to one F-port mirroring allowed between shared areas for ports 16-47. Port mirroring on ports 0-15 behaves the same as the FC4-32 Blade. • The configure command gives only a maximum login per port setting. The command allows over 127, where ports for the FC4-48 Blade will honor that value as long as its share area values are 127 or less. • Before replacing an FC4-32 Blade with an FC4-48 Blade, restore ports 16-31 of the FC4-32 Blade, if these ports are used for port swapping. Failure to do so will fault the FC4-48 Blade. The only way to restore the original settings is to add the FC4-32 Blade back into the slot and port swap the ports back to the port's default setting. • FC4-48 ports should not belong to the zone or in an administrative domain in which FICON devices reside. • The FC4-48 Blade does not support loop. Private L_Ports will be shown on these ports in switchshow, but will not participate in the fabric. • The porttest and spinfab commands on any platform will not work on E_Ports connected to an FC4-48 port. • The FC4-48 Fibre Channel port Blade is not supported to connect to the System z environments via FICON channels or via FCP zLinux on System z. To use the 4/256 SAN Director to attach to the System z environment, use the FC4-16 or FC4-32 Fibre Channel port blades. • In a zoning configuration with members D and P, where P is greater than or equal to 256, remove these configurations before downgrading to an earlier firmware version (5.1.x or 5.0.x). Otherwise, the downgrade will not be HA compatible with earlier versions. • All zones involving the shared ports (domain, port or WWN) of an FC4-48 Blade would be treated as session based in "interopmode 2" fabric configuration. • Do not insert the Blade until the system is running Fabric OS 5.2.1b or later. • iSCSI virtual target creation involves adding LUNs to the virtual targets. The user discovers the LUNs by executing the fclunquery command. Testing has revealed that some devices do not respond properly to the LUN query. The user will need to use tools from the array vendor to determine LUN information required for iSCSI target creation. • Any uppercase letters used for the CHAP user name will be transformed into lowercase. • Users may install up to four FC4-16IP iSCSI blades per 4/256 SAN Director chassis, or any combination of up to four blades (FC4-16IP and B-Series MP Router blades), not exceeding the individual Blade limit per chassis. Valid combinations include: • Three FC4-16IP blades + one B-Series MP Router Blade • Two FC4-16IP blades + two B-Series MP Router blades • One FC4-16IP Blade + two B-Series MP Router blades • Two FC4-16IP blades + one B-Series MP Router Blade HP StorageWorks Fabric OS 5.3.0b release notes 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

FC4–48 port Blade for
the 4/256 SAN Director
The HP StorageWorks 4/48 SAN Director Blade requires a minimum of Fabric
OS 5.2.0a. Do not insert the FC4–48 Blade into the 4/256 chassis until
the chassis is running Fabric OS 5.2.0a or later. After Fabric OS has been
updated and an FC4–48 has been installed, the Fabric OS will not be able to
be downgraded earlier than 5.2.0a until the FC4–48 is removed.
The FC4–48 Blade supports only core PID (fmt 1) in Secure Fabric OS.
NPIV is supported only in ports 0 to 15 of the FC4–48 Blade.
Regarding long distance buffer credits, the FC4–48 has 560 credits available
for long distance. The FC4–32 Blade has 624 credits available for long
distance.
Regarding port mirroring, the FC4–48 is restricted to one F-port mirroring
allowed between shared areas for ports 16–47. Port mirroring on ports 0–15
behaves the same as the FC4–32 Blade.
The
configure
command gives only a maximum login per port setting. The
command allows over 127, where ports for the FC4–48 Blade will honor that
value as long as its share area values are 127 or less.
Before replacing an FC4–32 Blade with an FC4–48 Blade, restore ports
16–31 of the FC4–32 Blade, if these ports are used for port swapping. Failure
to do so will fault the FC4–48 Blade. The only way to restore the original
settings is to add the FC4–32 Blade back into the slot and port swap the
ports back to the port’s default setting.
FC4–48 ports should not belong to the zone or in an administrative domain in
which FICON devices reside.
The FC4–48 Blade does not support loop. Private L_Ports will be shown on
these ports in
switchshow
, but will not participate in the fabric.
The
porttest
and
spinfab
commands on any platform will not work on
E_Ports connected to an FC4–48 port.
The FC4–48 Fibre Channel port Blade is not supported to connect to the
System z environments via FICON channels or via FCP zLinux on System z.
To use the 4/256 SAN Director to attach to the System z environment, use
the FC4–16 or FC4–32 Fibre Channel port blades.
In a zoning con
guration with members D and P, where P is greater than or
equal to 256, remove these con
gurations before downgrading to an earlier
rmware version (5.1.x or 5.0.x). Otherwise, the downgrade will not be HA
compatible with earlier versions.
All zones involving the shared ports (domain, port or WWN) of an FC4-48
Blade would be treated as session based in ”interopmode 2” fabric
con
guration.
FC4–16IP iSCSI Blade for
the 4/256 SAN Director
(continued)
Do not insert the Blade until the system is running Fabric OS 5.2.1b or later.
iSCSI virtual target creation involves adding LUNs to the virtual targets. The
user discovers the LUNs by executing the
fclunquery
command. Testing has
revealed that some devices do not respond properly to the LUN query. The
user will need to use tools from the array vendor to determine LUN information
required for iSCSI target creation.
Any uppercase letters used for the CHAP user name will be transformed into
lowercase.
Users may install up to four FC4–16IP iSCSI blades per 4/256 SAN Director
chassis, or any combination of up to four blades (FC4–16IP and B-Series MP
Router blades), not exceeding the individual Blade limit per chassis. Valid
combinations include:
Three FC4–16IP blades + one B-Series MP Router Blade
Two FC4–16IP blades + two B-Series MP Router blades
One FC4–16IP Blade + two B-Series MP Router blades
Two FC4–16IP blades + one B-Series MP Router Blade
HP StorageWorks Fabric OS 5.3.0b release notes
11