HP StorageWorks 2/32 HP StorageWorks SAN Switch Rack Mount Kit Installation In - Page 17
HP StorageWorks, SAN Switch 2/8 Version 3.1.x Installation Guide
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
b. For the SAN Switch 2/8, assemble the two inner rails (one on each side) to the switch and plenum using the appropriate number (from step 5) of #8-32 x 3/16-inch Phillips pan-head screws as shown in Figure 8. Note: The plenum is only a required part of this installation when the SAN Switch 2/8 is installed in the HP System/e rack. The plenum is not needed if the switch is installed in an HP 9000 Series or comparable EIA rack. Verify that the plenum (part number A7346-00001) is preinstalled on the SAN Switch 2/8 before proceeding. The plenum is required for the SAN Switch 2/8 rack mount only, as it allows air to dissipate at the rear of the rack, preventing overheating. If the plenum is not preinstalled on the SAN Switch 2/8, refer to the HP StorageWorks SAN Switch 2/8 Version 3.1.x Installation Guide for complete plenum installation instructions. Figure 8: Assembling the inner rails on a SAN Switch 2/8 with plenum SAN Switch Rack Mount Kit Installation Instructions 17