HP StorageWorks 8/80 Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01 - Page 348
firmwareShow, Synopsis, Description, Operands, Examples, See Also, firmwareDownload
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 348 highlights
2 firmwareShow firmwareShow Displays the Fabric OS versions on all firmware partitions in the system. Synopsis firmwareshow Description Use this command to display the FOS, SAS, and SA firmware versions. The command shows the firmware versions on both the primary and secondary partitions of the storage device. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7: switch:admin> firmwareshow Slot Name Appl Primary/Secondary Versions Status 2 FA4-16 FOS v6.1.1 v6.1.1 SAS v3.0.0 v3.0.0 DMM v3.0.0 v3.0.0 5 CP0 FOS v6.1.1 Standby * v6.1.1 6 CP0 FOS v6.1.1 Active v6.1.1 7 FA4-16 FOS v6.1.1 v6.1.1 SAS v3.0.0 v3.0.0 DMM v3.0.0 v3.0.0 * Local CP Note: If Local CP and Remote CP have different versions, retry the firmwaredownload command. See Also To display the firmware version on a switch: switch:admin> firmwareshow Appl Primary/Secondary Versions FOS v6.1.1 v6.1.1 SAS v3.0.0 v3.0.0 DMM v3.0.0 v3.0.0 firmwareDownload, firmwareDownloadStatus 318 Fabric OS Command Reference 53-1001337-01