HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.0d release notes (5697-7681 - Page 21

Fabric OS 6.1.0c

Page 21 highlights

Fabric OS 6.1.0c fixes Table 9 lists defects closed in the Fabric OS 6.1.0c firmware release. Table 9 Fabric OS 6.1.0c closed defects Closed defect summary Solution HP StorageWorks 8/40 SAN Switch running Fabric OS 6.1.0 may generate over-temperature warnings while at ambient temperature after booting up. Fixed in Fabric OS 6.1.0c Switch allows duplicate TI Zone members to be created or added. Fixed in Fabric OS 6.1.0c Out of Order frames delivered to DC SAN Backbone Director via FICON channel from HP StorageWorks 8/40 SAN Switch attached to a storage device (DASD). Fixed in Fabric OS 6.1.0c Running supportSave from CLI or Fabric Manager for DC SAN Director Backbone Directors takes longer than it does for other switch Fixed in Fabric OS 6.1.0c types. EE monitor counters may not get updated after performing switchdisable/switchenble or reboot. Fixed in Fabric OS 6.1.0c Third party storage center application does not survive in an FCIP network with 1% packet loss and 100 ms network latency. Fixed in Fabric OS 6.1.0c "seccertutil gencsr" is not accepted in non-interactive mode if parameter has a space in it. Fixed in Fabric OS 6.1.0c EZSwitch version 6.1 can not enable Web Tools after setting the switch IP using the IP discovery process. Fixed in Fabric OS 6.1.0c The TI Zone list page displayed by Web Tools was missing some entries on systems containing 48-port blades. Fixed in Fabric OS 6.1.0c IBM XRC Emulation allows FICON Disk Control Unit paths to be activated with DPR Mode. Fixed in Fabric OS 6.1.0c nl Workaround: Do not mix native and extended (FOS or USD-X/Edge) CHPIDs in the configuration. On HP StorageWorks 8/8, 8/24, 8/40 and 8/80 SAN Switch models: nl When normal fan activity is interrupted, the high revolution per minute (RPM) fan rate cycle time takes 1 hour. Fixed in Fabric OS 6.1.0c After changing IP address for SNMP and community level to '5', user will not be able to reset to default (0.0.0.0). Fixed in Fabric OS 6.1.0c Some TDM devices will not work when ARB is received before EFP on long distance links. Fixed in Fabric OS 6.1.0c FICON Tape Aborted sequence due to LS Early End status for DFSORT job. Fixed in Fabric OS 6.1.0c HP StorageWorks Fabric OS 6.1.0d release notes 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

Fabric OS 6.1.0c
xes
Table 9
lists defects closed in the Fabric OS 6.1.0c
rmware release.
Table 9 Fabric OS 6.1.0c closed defects
Closed defect summary
Solution
HP StorageWorks 8/40 SAN Switch running Fabric OS 6.1.0 may
generate over-temperature warnings while at ambient temperature
after booting up.
Fixed in Fabric OS 6.1.0c
Switch allows duplicate TI Zone members to be created or added.
Fixed in Fabric OS 6.1.0c
Out of Order frames delivered to DC SAN Backbone Director via
FICON channel from HP StorageWorks 8/40 SAN Switch attached
to a storage device (DASD).
Fixed in Fabric OS 6.1.0c
Running
supportSave
from CLI or Fabric Manager for DC SAN
Director Backbone Directors takes longer than it does for other switch
types.
Fixed in Fabric OS 6.1.0c
EE monitor counters may not get updated after performing
switchdisable
/
switchenble
or reboot.
Fixed in Fabric OS 6.1.0c
Third party storage center application does not survive in an FCIP
network with 1% packet loss and 100 ms network latency.
Fixed in Fabric OS 6.1.0c
"
seccertutil gencsr
" is not accepted in non-interactive mode
if parameter has a space in it.
Fixed in Fabric OS 6.1.0c
EZSwitch version 6.1 can not enable Web Tools after setting the
switch IP using the IP discovery process.
Fixed in Fabric OS 6.1.0c
The TI Zone list page displayed by Web Tools was missing some
entries on systems containing 48-port blades.
Fixed in Fabric OS 6.1.0c
IBM XRC Emulation allows FICON Disk Control Unit paths to be
activated with DPR Mode.
Fixed in Fabric OS 6.1.0c
Workaround: Do not mix native
and extended (FOS or USD-X/Edge)
CHPIDs in the con
guration.
On HP StorageWorks 8/8, 8/24, 8/40 and 8/80 SAN Switch
models:
When normal fan activity is interrupted, the high revolution per
minute (RPM) fan rate cycle time takes 1 hour.
Fixed in Fabric OS 6.1.0c
After changing IP address for SNMP and community level to ‘5‘, user
will not be able to reset to default (0.0.0.0).
Fixed in Fabric OS 6.1.0c
Some TDM devices will not work when ARB is received before EFP on
long distance links.
Fixed in Fabric OS 6.1.0c
FICON Tape Aborted sequence due to LS Early End status for
DFSORT job.
Fixed in Fabric OS 6.1.0c
HP StorageWorks Fabric OS 6.1.0d release notes
21