HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.2b release notes (5697-0351 - Page 31
Fabric OS 6.1.2b fixes, lists defects closed in the Fabric OS 6.1.2b firmware release.
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Fabric OS 6.1.2b fixes Table 16 lists defects closed in the Fabric OS 6.1.2b firmware release. Table 16 Fabric OS 6.1.2ab closed defects Closed defect summary CALD allocated shared memory may not be released, causing the switch to run out of shared memory, leading to high CPU load and inability to run CLI commands. Solution Workaround prior to upgrade: Run HA failover to workaround this issue. Fixed in Fabric OS 6.1.2b. SNMPd panic/restart due to segmentation fault caused by out of memory condition. Caused by FSPF timeout with neighbor switch during Fixed in Fabric OS 6.1.2b. out of memory recovery. A switch panic occurs due to CALD memory leak leading to out of memory condition while running management applications. Fixed in Fabric OS 6.1.2b. Class 2 ACK is not forwarded from F_Port to N_Port in Access Gateway mode, causing the Name Server to abort the exchange. Fixed in Fabric OS 6.1.2b. HP StorageWorks 8/40 switch may get an error message, after a power cycle, that Fan/PS is not supplying power and fan speeds not available. Workaround prior to upgrade: When the failure is seen at switch boot up time, it can be safely ignored; it results from spurious sensor reading below minimum. Fixed in Fabric OS 6.1.2b. HP StorageWorks Fabric OS 6.1.2b release notes 31