HP Surestore 15 Slot with DLT4000 Digital Linear Tape SCSI-2 Drive and SCSI-3 - Page 145
Device # SCSI ID, SCSI Device entries
View all HP Surestore 15 Slot with DLT4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Library SCSI-3 Command Set Read Buffer Command (3CH) Format rev: 0 = The report format with 14 bytes per target device. Used on code revisions below 1.20x; 1 = The report format with 24 bytes per target device. Controller number: Controller number of the above type (i.e., controller 1 of type fibre). Device valid: 1 = information in Device fields are valid; 0 = not valid. Addr valid: 1 = information in link address is valid; 0 = not valid. WWN valid: 1 = information in Worldwide Names is valid; 0 = not valid. LVD/HVD: 1 = Low voltage differential board; 0 = High voltage differential board. Bus 1 fault: 1 = SCSI bus 1 has a fault; 0 = no fault. Bus 2 fault: 1 = SCSI bus 2 has a fault; 0 = no fault. # SCSI Device entries: Is equal to the number of device entries following (14 bytes each). Bus #: 1 = SCSI bus 1; 2 = SCSI bus 2. Device # SCSI ID: Device # SCSI ID, one entry per SCSI device in the library. Device # OLR Status: 0 = Drive invalid 1 = Online good 2 = Online pending 3 = Offline failed pending 4 = Offline failed 5 = Offline good pending 6 = Offline good 7 = Offline missing 8 = Offline library 9 = Offline missing library Device # type: 0 = library; 1 = DLT7000; 2 = DLT8000; F = Unknown. Device # serial number: Serial number of device, ASCII string padded at end with zeros (currently returns all 0xff). Link address: The link address of the fibre channel board (AL_PA or FLA). Link up: 0 = link not detected; 1 = link detected. Chapter 2 2- 101