HP Surestore 15 Slot with DLT4000 Digital Linear Tape SCSI-2 Drive and SCSI-3 - Page 150
Device # vendor ID, Device # OLR Status
View all HP Surestore 15 Slot with DLT4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 150 highlights
Library SCSI-3 Command Set Read Buffer Command (3CH) = synch 5 Mbytes; 2 Fast 10 Mbytes; 3 = Ultra 20 Mbytes; 7 = Unknown. Device # SCSI ID: Device # SCSI target ID. Device type: 0 = library; 1 = DLT7000; 2 = DLT8000; 3 = Ultrium LTO; 4 = DLT1 (Benchmark). Device # OLR Status: 0 = Drive invalid 1 = Online good 2 = Online pending 3 = Offline failed pending 4 = Offline failed 5 = Offline good pending 6 = Offline good 7 = Offline missing 8 = Offline library 9 = Offline missing library Device # serial number: Serial number of device, ASCII string padded at end with zeros. Device # vendor ID: The vendor ID of the drive. 8-byte ASCII string padded a the end with zeros. Link address: The link address of the fibre channel board (AL_PA or FLA). Bypass/active: 1 = Fibre transceiver is in loopback; 0 = Fibre transceiver is able to connect to an outside link. Link up: 0 = link not detected; 1 = link detected. Link init status: 0 = Initialization pending; 1 = Initialization failed; 2 = Initialization successful. Addr mode: Address mode: 0 = hard; 1 = soft; 2 = firm. Connection: Connection type. 0 = none; 1 = loop; 2 = fabric. Worldwide name (WWN): A unique registered name that is given to each fibre channel board. PAL revision: PAL's revision. Board Revision: 0 = The HVD 509 board; 3 = The LVD 519 board; 4 = The HVD 529 board; 5 = The LVD high-performance 539 board; 6 = The HVD high-performance 549 board. Bus # fault: 1 = SCSI bus # has a fault; 0 = no fault. 2- 106 Chapter 2