HP Surestore 15 Slot with DLT7000 Digital Linear Tape SCSI-2 Drive and SCSI-3 - Page 136
Drive Status for Ultrium LTO, For more information on Drive General Status
View all HP Surestore 15 Slot with DLT7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Library SCSI-3 Command Set Read Buffer Command (3CH) Table 2-73 Drive Status for Ultrium LTO Byte 7 6 5 4 3 2 1 0 0 IPMB Message status 1 Board status 2 Board type 3 Been Boot setup code Reserved Controller number 4 Reserved 5 6 7 8-15 Fan Drive detect power Reserved Drive connected For factory use Reserved Drive statusa Reserved a. For more information on Drive General Status, see the LTO Specification for a Tape Drive Automation Controller Interface. IPMB Message status: See Table 2-68 on page 2-87. Board status: Current status of the controller board. See Table 2-69 on page 2-88. Board type: The type of controller. See Table 2-70 on page 2-88. Been setup: Set if the controller has been given its setup variables. Boot code: Is the controller current running boot code? 1 = Yes; 2 = No. Controller number: Controller number of the above type (i.e., controller 1 of type drive). Fan detect: 1 = Fan is spinning; 0 = Fan is not spinning. Drive power: 1 = Power on to drives; 0 = Power off to drives. Drive connected: 1 = Drive is connected on RS422; 0 = Drive is not connected on RS422 or drive power is off. 2- 92 Chapter 2