HP Surestore 15 Slot with DLT7000 Digital Linear Tape SCSI-2 Drive and SCSI-3 - Page 156
Table 2-89, Partial Availability Conditions, Error Status, Causes, Drives Fw error
View all HP Surestore 15 Slot with DLT7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
Table 2-89 Library SCSI-3 Command Set Read Buffer Command (3CH) Partial Availability Conditions Error Status Causes Drive(s) not present Drive(s) offline Drive(s) online pending Drive(s) not available on fibre channel Drive(s) Fw error Drive critical Drive needs cleaning Mag(s) missing Door(s) open Mailslot open SE connect to LVDS Library could not detect the drive modules. Drive(s) taken offline by library controller. • Drive(s) failed power-on test. • Drive module board failed power-on test. • Failed serial communication to drive. • Failed load/unload. Drive(s) taken offline by front panel operator. Drive(s) taken offline by host computer. Drive(s) are present and powered up, but have incompatible firmware. Drive(s) are detected by library controller but are not detected by any of the fibre channel cards. Drive(s) are present and powered up but have incompatible firmware. A critical error has occurred on a drive. A drive needs cleaning. Library could not detect all the magazines. One or more tape doors are open. Mailslot door is open. The low voltage differential SCSI bus has a single-ended connection. 2- 112 Chapter 2