HP Surestore 64 FW 05.01.00 and SW 07.01.00 Director Release Notes (AA-RTDVC-T - Page 18

HSG80 Transparent Mode Not Supported with IBM AIX, Workaround

Page 18 highlights

Known Issues HSG80 Transparent Mode Not Supported with IBM AIX Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in Multibus mode with the Director 2/64 and Director 2/140. Transparent mode is not supported at this time. Workaround None. HSG80 Transparent Mode Not Recommended with Controller in SCSI-3 Mode with HP-UX Operating Systems Due to an issue with non-existent duplicate LUNs being displayed with the HP-UX operating systems, the HSG80 controller is restricted to SCSI-2 mode of operation when set to Transparent failover mode. SCSI-3 mode of operation in Multibus failover mode is fully supported with the use of Secure Path software, Version 3.0 or later versions. Workaround None. ISL Disconnect Causes NOS Error with the OpenVMS Operating Systems When an ISL connection is physically removed between directors or switches, the Fibre Channel Adapter model FCA2354 transmits a Not Operational Sequence (NOS) error. This is observed as an entry in the HAFM server Link Incident log for the port in which the FCA2354 is attached. The director's Hardware View also displays a yellow triangle icon over the port that detected this incident. The fabric operation or data movement is not disrupted by these incidents, which can be cleared using the following procedure. Workaround Use these steps to clear the incident alerts. 1. At the HAFM Hardware View, click the port module to open the Port Card View. 2. Right click on the port with the yellow triangle icon, and choose Clear Link Incident Alert(s). 18 Director Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Known Issues
18
Director Release Notes
HSG80 Transparent Mode Not Supported with IBM AIX
Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in Multibus
mode with the Director 2/64 and Director 2/140. Transparent mode is not
supported at this time.
Workaround
None.
HSG80 Transparent Mode Not Recommended with Controller in SCSI-3
Mode with HP-UX Operating Systems
Due to an issue with non-existent duplicate LUNs being displayed with the
HP-UX operating systems, the HSG80 controller is restricted to SCSI-2 mode of
operation when set to Transparent failover mode.
SCSI-3 mode of operation in Multibus failover mode is fully supported with the
use of Secure Path software, Version 3.0 or later versions.
Workaround
None.
ISL Disconnect Causes NOS Error with the OpenVMS Operating Systems
When an ISL connection is physically removed between directors or switches, the
Fibre Channel Adapter model FCA2354 transmits a Not Operational Sequence
(NOS) error. This is observed as an entry in the HAFM server Link Incident log
for the port in which the FCA2354 is attached. The director’s Hardware View also
displays a yellow triangle icon over the port that detected this incident. The fabric
operation or data movement is not disrupted by these incidents, which can be
cleared using the following procedure.
Workaround
Use these steps to clear the incident alerts.
1.
At the
HAFM Hardware View
, click the port module to open the
Port Card
View
.
2.
Right click on the port with the yellow triangle icon, and choose
Clear Link
Incident Alert(s)
.