HP Surestore 64 FW 09.0200 HP StorageWorks Director and Edge Switch Release No - Page 15
Full-fabric capability for Edge Switch 2/12
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Reinstalling feature licenses Feature licenses (or keys) must be reinstalled after performing a factory reset on an Edge Switch or Director to regain use of the licensed features (for example, SANtegrity Binding). CTP controls port lights Port lights on the Edge Switches and Directors are controlled by the CTP. Certain activities such as firmware updates, IPLing the CTP, or switching over to the backup CTP (Director) can cause these port lights to extinguish momentarily until control is reasserted by the CTP. The actual Fibre Channel traffic is not affected during these times. Full-fabric capability for Edge Switch 2/12 Unlike other Edge Switch and Director products, a PFE key controls Edge Switch 2/12 E_Port-to-E_Port connections. After purchasing and installing the feature key, you can configure for E_Port connections on any of the active ports. The feature key includes distance support. With firmware 06.00.00 and later, the Edge Switch 2/12 ships with five BB_credits allocated to each port. After activation of the Full Fabric feature on a switch, each port has 12 BB_Credits allocated to support up to 12-km links at 2-Gb/s speed. Support for speed Auto-Negotiate Auto-negotiate is supported. However, HP recommends that the port speed for E_Ports (for Interswitch links, or ISLs) be set to a specific port speed (1Gb/sec, 2Gb/sec, or 4Gb/sec as appropriate for the speed of the Directors or Edge Switches being connected) instead of to Negotiate. Using a specific port speed decreases the time for a fabric build in response to some perturbation event in the fabric. Similarly, setting a specific port speed for N_Ports also decreases fabric build time. However, setting a specific port speed for N_Ports is not required. There are a few older HBA devices that do not always succeed in logging in to a switch port when the port speed is set for auto-negotiate. Workaround If an older HBA has difficulty logging into a switch port that has its port speed configured as Negotiate, configure that port speed to 1Gb/sec, 2Gb/sec, or 4Gb/sec according to the operation speed of the HBA connected to that port. Known issues in firmware 09.02.00 Table 6 lists the known issues in firmware 09.02.00. Table 6 firmware 09.02.00 known issues Issue Workaround For the Director 2/64 in a FICON environment, when a QPM is swapped for an XPM, or an XPM is swapped for a QPM, the PDCMs of the affected ports are not cleared. PDCMs cannot be configured via HAFM after this happens. Do not immediately replace a QPM port card with an XPM port card, or an XPM port card with a QPM port card. To make this change, remove the first port card (QPM or XPM), install a UPM port card temporarily (for two minutes), and then remove the UPM and install the desired port card (QPM or XPM). For Edge Switches, the alias database persists after Alias Database can be successfully cleared through CLI a configuration reset, where it should be cleared. and EFCM basic. Attempts to activate a large zone set through OSMS Temporarily disable CT authentication, and then when CT authentication is enabled occasionally activate the zone set. may not be successful. Director and Edge Switch release notes 15