HP Surestore Disk System fc10 Hewlett-Packard HP SureStore E Disk System FC10 - Page 100
Problem, Description, HWEvent, Category, State, Status, Probable Cause/Solution
View all HP Surestore Disk System fc10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
Problem HWEvent LED Description Category State Status SAM STM Probable Cause/Solution Disk fault LED is on Critical Power supply Critical LED is amber Fault Critical LED on Amber Critical Fan LED is amber LCC fault LED is on Critical Critical LCC fault none LED is on and the disk system beeps GBIC fault LED is on Critical Amber Critical LCC Fault LED on Critical LCC none Fault on Tx Fail none LED on (See STM Disk hardware is faulty. Replace the Disk Tool) disk. Critical - An incompatible or defective component caused a temporary fault. - Power supply hardware is faulty. Unplug the power cord and wait for the LED to turn off. Reinsert the power cord. If fault persists, replace the power supply. Critical Fan has slowed or stopped. Replace the fan. Critical LCC hardware is faulty. Replace the LCC. none none The Enclosure ID on the installed LCC does not match the Enclosure ID on the peer LCC. Reset the Enclosure ID and reinsert the LCC. - GBIC transmission circuit has failed. - GBIC is not receiving power. Reseat the GBIC. If problem persists, replace GBIC. If the replacement GBIC fails, contact HP technical support. 100