HP Surestore E Disk Array XP256 Familiarization Guide - Page 44
Warning of M bus CHK error B SMP, Warning of F bus DISABLE BSA detected
View all HP Surestore E Disk Array XP256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Error Type M-bus error (DKA side) F-bus error F-bus error (CHA side) F-bus error (DKA side) CHA, CHK2 (processor) CHS, CHK2 (processor) Error Warning of M bus open (SMP detected) Warning of CHK error (SMP detected) Warning of M bus CHK error (B) (SMP detected) Warning of M bus DISABLE (SMP detected) Warning of M bus ABTRST (SMP detected) Warning of SM DISABLE (SMP detected) M bus arbiter enable off Bus blocking Warning of F bus DISABLE (BSA detected) F-bus arbiter enable off Warning of F bus open (BSA detected) Warning of LIVEINS (BSA detected) Warning of CHK error (BSA detected) Warning of F bus DISABLE (BSA detected) F-bus arbiter enable off Warning of F bus open (BSA detected) Warning of LIVEINS (BSA detected) Warning of CHK error (BSA detected) RCHA temporary error RCHA blocking SCP path temporary error SCP path blocked Ref 22 23 FF 51 FF 52 FF 54 SIM 28 Severity F1 Moderate F1 Moderate F1 Moderate FF 55 F1 FF 56 F1 FF 57 F1 FF 58 F1 FF FA F1 FF 80 F1 FF B1 F1 FF FC F1 FF FD F1 FF FE F1 FF 30 F1 FF 31 F1 FF 7C F1 FF 7D F1 FF 7E F1 3F 84 F1 3F 85 F1 3F 86 F1 3F 87 F1 Moderate Moderate Moderate Moderate Serious Moderate Moderate Moderate Moderate Moderate Moderate Moderate Moderate Moderate Moderate Service Service Service Service 44