Command-line options

Page 10 highlights

3 Command-line options See the following table for a list of command-line options for HPUSBPortMgr.exe, which is located in the System32 folder on 32-bit systems and in the SysWOW64 folder on 64-bit systems. After making changes using the command line, you must restart the thin client for changes to take effect. TIP: Options are not case sensitive. /USBStor-ReadOnly Sets access to USB mass storage devices as read-only. /USBF {Enable|Disable} Enables or disables access for all USB devices not enabled in the whitelist. /Add "VendorID=VendorID;ProductID=ProductID;ClassID=ClassID;Allow=HexValue;Name=String" Adds an item to the whitelist. /Delete "VendorID=VendorID;ProductID=ProductID;ClassID=ClassID;Allow=HexValue;Name=String" Removes an item from the whitelist. /Allow "VendorID=VendorID;ProductID=ProductID;ClassID=ClassID;Allow=HexValue;Name=String" Allows access for a whitelist item. /Block "VendorID=VendorID;ProductID=ProductID;ClassID=ClassID;Allow=HexValue;Name=String" Blocks access for a whitelist item. /Export FilePath Exports the HP USB Port Manager configuration to a PowerShell script. /Show Displays the current configuration information for HP USB Port Manager. /Help - or - /? Displays command-line help. Examples: /USBStor-ReadOnly Disable /USBF Enable HPUSBPortMgr.exe /Add "VendorID=0x0000;ProductID=0x0000;ClassID=0x09;Allow=0x01;Name=Hub" HPUSBPortMgr.exe /Block "VendorID=0x0000;ProductID=0x0000;ClassID=0x09;Allow=0x01;Name=Hub" HPUSBPortMgr.exe /Export C:\hpusbportmanager.ps1 4 Chapter 3 Command-line options

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

3
Command-line options
See the following table for a list of command-line options for HPUSBPortMgr.exe, which is located in the
System32 folder on 32-bit systems and in the SysWOW64 folder on 64-bit systems.
After making changes using the command line, you must restart the thin client for changes to take effect.
TIP:
Options are not case sensitive.
/USBStor-ReadOnly
Sets access to USB mass storage devices as read-only.
/USBF {Enable|Disable}
Enables or disables access for all USB devices not enabled in the whitelist.
/Add "VendorID=
VendorID
;ProductID=
ProductID
;ClassID=
ClassID
;Allow=
HexValue
;Name=
String
"
Adds an item to the whitelist.
/Delete "VendorID=
VendorID
;ProductID=
ProductID
;ClassID=
ClassID
;Allow=
HexValue
;Name=
String
"
Removes an item from the whitelist.
/Allow "VendorID=
VendorID
;ProductID=
ProductID
;ClassID=
ClassID
;Allow=
HexValue
;Name=
String
"
Allows access for a whitelist item.
/Block "VendorID=
VendorID
;ProductID=
ProductID
;ClassID=
ClassID
;Allow=
HexValue
;Name=
String
"
Blocks access for a whitelist item.
/Export
FilePath
Exports the HP USB Port Manager configuration to a PowerShell script.
/Show
Displays the current configuration information for HP USB Port Manager.
/Help
– or –
/?
Displays command-line help.
Examples:
/USBStor-ReadOnly Disable
/USBF Enable
HPUSBPortMgr.exe /Add "VendorID=0x0000;ProductID=0x0000;ClassID=0x09;Allow=0x01;Name=Hub"
HPUSBPortMgr.exe /Block "VendorID=0x0000;ProductID=0x0000;ClassID=0x09;Allow=0x01;Name=Hub"
HPUSBPortMgr.exe /Export C:\hpusbportmanager.ps1
4
Chapter 3
Command-line options