Honeywell 2020-5B User Guide - Page 185

Minimizing Bluetooth/ISM Band Network Activity, Auto Reconnect Mode

Page 185 highlights

B Minimizing Bluetooth/ISM Band Network Activity The settings described below can help you customize the re-linking behavior of the cordless linear imaging system to obtain the best compromise between convenience and low interference. Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless networks, cordless phones, and Bluetooth. Auto Reconnect Mode Auto Reconnect controls whether or not the image scanner automatically begins the re-link process when a loss of connection is detected. When the Auto Reconnect On bar code is scanned, the image scanner begins the re-link process immediately, without user intervention. Default = Auto Reconnect On. * Auto Reconnect On Auto Reconnect Off The table below shows the results of the Auto Reconnect On and Off settings: Event Image scanner out of range Base reset (firmware upgrade or power cycle) Image scanner power down due to Power Time-Out Timer setting (see page 3-4) Auto Reconnect On Auto Reconnect Off Re-link occurs automatically. If maximum number of link attempts (see Maximum Link Attempts on page B-2) is unsuccessful, then the trigger must be pulled or the image scanner must be placed in the base unit to relink. The trigger must be pulled to initiate re-linking. Image scanner behaves as if out of range. No attempt to re-link made while base unit is powered off. Trigger must be pulled to initiate relinking. Trigger must be pulled or the image scanner must be placed in the base unit to re-link. (Note: image scanner re-links on power up, but powers on due to one of the above actions.) B - 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

B - 1
B
Minimizing Bluetooth/ISM Band
Network Activity
The settings described below can help you customize the re-linking behavior of
the cordless linear imaging system to obtain the best compromise between
convenience and low interference.
Note:
ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless
networks, cordless phones, and Bluetooth.
Auto Reconnect Mode
Auto Reconnect controls whether or not the image scanner automatically begins
the re-link process when a loss of connection is detected.
When the
Auto
Reconnect On
bar code is scanned, the image scanner begins the re-link
process immediately, without user intervention.
Default = Auto Reconnect On.
The table below shows the results of the Auto Reconnect On and Off settings:
Event
Auto Reconnect On
Auto Reconnect Off
Image scanner out
of range
Re-link occurs
automatically.
If
maximum number of link
attempts (see
Maximum
Link Attempts
on page
B-2) is unsuccessful,
then the trigger must be
pulled or the image
scanner must be placed
in the base unit to re-
link.
The trigger must be pulled
to initiate re-linking.
Base reset
(firmware upgrade
or power cycle)
Image scanner behaves
as if out of range.
No attempt to re-link
made while base unit is
powered off.
Trigger must
be pulled to initiate re-
linking.
Image scanner
power down due to
Power Time-Out
Timer setting (see
page 3-4
)
Trigger must be pulled or the image scanner must be
placed in the base unit to re-link.
(Note: image scanner re-links on power up, but
powers on due to one of the above actions.)
* Auto Reconnect On
Auto Reconnect Off