Honeywell CT2400 Owner's Manual - Page 13
Troubleshooting Guide
View all Honeywell CT2400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Troubleshooting Guide IF... Display will not come on. Temperature display will not go lower than 45° F r" C] or higher than 88° F [31 0 C] during programming. Temperature change occurs at the wrong times. Heating will not come on. THEN... Set the system switch to OFF. Remove batteries. Insert batteries backward forat least five seconds to reset thermostat. Replace batteries correctly. Display should come on. Make sure batteries are fresh and installed correctly. Gently clean battery contacts using a soft pencil eraser. Do not use anything abrasive on clips. You have reached the temperature setting limit. The setting range is 45° F to 88°F [7°Cto310 C]. Check the program times for the period in question. Be sure that AM and PM indications are correct. Make sure the current day and time are correct. Reprogram if necessary. Check that switch on thermostat is set to HEAT. 29 Heating will not come on (continued). 9 Check the system fuse or circuit breaker and replace or reset if necessary. Check for correct wiring and good connections. Jumper wires R and W. If heat does not come on, contact your heating dealer. If display is blank or says "bAt Lo," install fresh batteries. If temperature setting is higher than current tempera- ture, and SYSTEM ON indicator is lit, contact Honeywell Customer Assistance at 1-800-468-1502. Cooling will not come on. Check that switch on thermostat is set to COOL. : Check the system fuse or circuit breaker and replace or reset if necessary. Check for correct wiring and good connections. Jumper wires Rc and Y. If cooling does not come on, contact your cooling dealer. If display is blank or says "bAt Lo," install fresh batteries. The thermostat has a built-in time delay on cooling. Allow five to ten minutes after changing the setting before the air conditioner starts. 30 The house is too warm or too cool. SYSTEM ON indicator is lit, but no heat is coming from the registers. Make sure outdoor disconnect is engaged (on). If temperature setting is lower than current temperature, and SYSTEM ON indicator is lit, move system switch from COOL to OFF for ten minutes. After ten minutes, return switch to COOL position. If air conditioner comes on, compressor may have reached its high limit temperature protection and shut down. If air conditioner does not come on after the ten minutes and the SYSTEM ON indicator is lit, contact Honeywell Consumer Assistance at 1-800-468-1502. If 2- or 4-wire installation, verify that R-Rc jumper is installed. s Press RUN PROGRAM key to check the current temperature setting. s I f desired, change the temperature setting. See I)age 14. Wow time for the furnace to heat up and the fan to :ome on before checking for heat at the register. (Check to make sure system on-time is set (:orrectly according to pages 16 and 17.) 31