Honeywell CT3600 Owner's Manual - Page 7
Step 3. Mount Thermostat Wallplate - wiring
View all Honeywell CT3600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
STEP 3. MOUNT THERMOSTAT WALLPLATE ❑ Separate the wallplate from the thermostat by placing your thumb or fingers between the bottom of the wallplate and the thermostat, and pulling the wallplate up and away from the thermostat. See illustration at right. ❑ Position the wallplate on the wall. Level the wallplate for appearance if desired. Use a pencil to mark the two mounting holes that best fit the application. ❑ Remove the wallplate from the wall. Drill two 3/16 in. holes in wall (if drywall) as shown. For materials such as plaster or wood, drill 7/32 in. holes where marked. Gently, tap the (provided) anchors into the drilled holes until they are flush with the wall. ❑ Reposition the wallplate over the holes. Pull the wires through the wiring opening. Loosely insert mounting screws into each of the holes. ❑ Level the wallplate if desired. Thermostat functions properly when not level. ❑ Tighten mounting screws. WIRES THROUGH WALL WALL WALL ANCHORS (2) M16427 MOUNTING HOLES MOUNTING SCREWS M15044 7 69-1642