Honeywell CT50K Owner's Manual - Page 4

Set fan operation switch CT51/CT55, Finish installation, Set heat anticipator select models - arrow manual

Page 4 highlights

CT50 Series • Owner's Manual Set fan operation switch (CT51/CT55) Move the switch to the proper setting for your system: F: For gas or oil heating systems, leave the fan operation switch in this factory-set position (for systems that control the fan in a call for heat). E: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.) Set heat anticipator (select models) Move the adjustment arrow to the proper setting for your system (see table below). Your system Steam Hot water heat Warm air (high efficiency) Warm air (standard) Electric heat Setting 1.2 0.8 0.8 0.4 0.3 Finish installation 1. Align the slots on the cover with tabs on the sides of the base, then push gently until the cover snaps into place. 2. Restore power at the heating/cooling system, or at the fuse/circuit-breaker panel. Tab 69-2040EFS-01 4 M23 M23795 M23796

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

CT50 Series • Owner's Manual
69-2040EFS—01
4
1.
Align the slots on the cover with tabs on
the sides of the base, then push gently
until the cover snaps into place.
2. Restore power at the heating/cooling sys-
tem, or at the fuse/circuit-breaker panel.
Move the switch to the proper setting for your
system:
F:
For
gas or oil heating systems, leave the
fan operation switch in this factory-set position
(for systems that control the fan in a call for
heat).
E:
Change the switch to this setting for heat
pump or electric heat systems. (This setting
is for systems that allow the thermostat to
control the fan in a call for heat, if a fan wire is
connected to the
G
terminal.)
Set fan operation switch (CT51/CT55)
Finish installation
M23796
Tab
Move the adjustment arrow to the
proper setting for your system
(see table below).
Your system
Setting
Steam
1.2
Hot water heat
0.8
Warm air (high efficiency)
0.8
Warm air (standard)
0.4
Electric heat
0.3
Set heat anticipator (select models)