Honeywell HM509 Owners Guide - Page 24
Specifications - model
View all Honeywell HM509 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Installation Guide Specifications Capacity: HM512: 12 gallons per day (gpd) (45 liters per day [lpd]) HM509: 9 gpd (34 lpd) HM506: 6 gpd (23 lpd) Humidified Area: House Air Changes HM512 HM509 HM506 Description Per Hour Loose Two 2000 ft2 1300 ft2 1000 ft2 Average One 2500 ft2 1800 ft2 1500 ft2 Tight One-half 3000+ ft2 2500 ft2 2000 ft2 Weight: Model Empty Filled with Water HM512 9 lbs. 15 lbs. HM509 9 lbs. 14.5 lbs. HM506 8 lbs. 12 lbs. • Dimensions: 11-1/4 in. W x 19 in. H x 9 in. D • Humidifier Operating Temperature Range: 34ºF- 120ºF (1.1ºC-49ºC) • Remote Hose/Nozzle Operating Temperature Range: -50ºF-250ºF (-46ºC-121ºC) • Operating Humidity Range: 0-95% RH, noncondensing Drain Operation • Auto flushing is configurable to 10, 20 or 30 hours of operational time (heating element active). • During auto flushing, cold water will enter the tank to lower water temperature below 140ºF (60ºC) before draining. • During manual flush (performed by pressing the EMPTY button) initial water temperature may be above 140ºF (60ºC). Ensure drain outlet is not exposed and use caution when pressing the EMPTY button, and do NOT attempt to remove the tank with water in it. • Flush cycle takes approximately 15 minutes to empty the tank completely. To override, press/hold the EMPTY button while the "Clean Tank" light is blinking. • Drain Hose Operating Temperature Range: 34ºF- 212ºF (1.1ºC-100ºC) Electrical Ratings and Tolerances Input Ratings • Power Supply: 120VAC +10/ -15%, 60Hz - HM512: 1440W at 120VAC at full load - HM509: 1200W at 120VAC at full load - HM506: 840W at 120VAC at full load • HM512: 12A, 120VAC • HM509: 10A, 120VAC • HM506: 7A, 120VAC • 15A, 120VAC interlock switch • Thermostat/HVAC power monitor (R to C): 10mA resistive at 24VAC • Field wiring terminals: 18-22 ga. solid • HVAC power/airflow monitor: 10 mA resistive at 24 VAC Output Ratings • Relay output contacts: - Fan: 1.5A full load, 7.5A locked rotor at 24VAC - Heat and Backup: 15A resistive at 120VAC • Fill Solenoid: 0.1A at 120VAC, 0.5 PF • Drain Solenoid: 0.1A at 120VAC, 0.5PF • Humidistat output contacts: 10mA resistive at 24VAC • Humidistat power supply: 100mA at 24VAC CAUTION Hot water temperature above 140°F (60°C) can cause burns from scalding. Standards & Approval Body Requirements Underwriters Laboratories: UL998, File no. E185662. Federal Communications Commission: Class B compliance, File no. YU555. Intended to be used in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, and the rules of the Canadian Electrical Code (CEC), Part 1, C22.1. 69-2036EFS-07 22