Quick Installation Guide System Setup 9. 1) Press both and buttons simultaneously for 3 seconds to enter or exit the setup menu. 2) To advance to the next function, briefly press both and buttons simultaneously. 3) To change the setting, press the or button. DISPLAY DESCRIPTION OPTIONS 1 Temperature display °C or °F Time display 12 h or 24 h Early Start 2 On or Off Heating cycles per hour 3 2, 3, 4, 5 or 6 4 Cooling cycles per hour 3 2, 3, 4, 5 or 6 5 1 Default settings are shown in bold and underlined. 2 See page 3 of Operating Manual. 3 Use the system switch to switch between the two parameters. 4 For optimal heating control, use the setting that matches your system as follows: 2=30 min (steam, gravity), 3=20 min (hot water, 90%+ high-efficiency furnace), 4=15 min (gas or oil), 5=12 min (alternate setting for gas or oil), 6=10 min (electric). 5 The corresponding cooling cycle lengths are as follows: 2=30 min, 3=20 min, 4=15 min, 5=12 min, 6=10 min 09-08 11 Printed in U.S.A.