Honeywell RTH7600D Owner's Manual - Page 27
Heating or cool, ing system does, not respond, Wait appears, on the screen, Heat pump is, sues cool - reset
View all Honeywell RTH7600D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
SETUP WIRING Troubleshooting RTH7600 Heating or cool- Press SYSTEM to set system to Heat. ing system does Make sure the temperature is set higher not respond than the Inside temperature. Press SYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature. Check circuit breaker and reset if necessary. Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely. Wait 5 minutes for the system to respond. "Wait" appears on the screen Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor. Heat pump is- Check Function 0190: Heat Pump sues cool air in Changeover Valve to make sure it is heat mode, or properly configured for your system warm air in cool (see page 17). mode ASSISTANCE TROUBLESHOOTING 25 69-2206EF-01