Hoover U5468900 Manual - Page 11

The agitator brush roll, The edge groomers, Lubrication, Thermal protector, Service - model number

Page 11 highlights

3-15 Replacing bottom plate Reposition bottom plate and 4 Phillips head screws. Tighten screws securely. The edge groomers When to replace The edge groomers, located on both sides of the nozzle, should be replaced when they appear worn. What to buy When purchasing edge groomers, ask for HOOVER part No. 39511004. How to replace Disconnect cleaner from electrical outlet. Remove bottom plate as described in "The belt" section (Fig. 3-10). The agitator brush roll When to replace When agitator brushes are worn, the agitator should be replaced. To check condition of brushes, disconnect cleaner from electrical outlet. Move edge of a card across bottom plate while turning agitator. To maintain cleaning effectiveness, replace agitator if brushes do not touch card. What to buy Your cleaner requires either a 13" or 15" agitator. When purchasing a new agitator, ask for one of the following: 13" - HOOVER part No. 48414110 15" - HOOVER part No. 48414115 3-17 Installing groomers Lift off both old edge groomers and slide new edge groomers into position as shown. Reposition bottom plate and secure with 4 Phillips head screws. 3-16 How to replace Disconnect cleaner from electrical outlet. Remove bottom plate, belt and agitator following directions in "The belt" section beginning with Fig. 310. Discard old agitator. Continue following the directions in "The belt" section to reposition belt, new agitator and bottom plate. Lubrication The motor is equipped with bearings that contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Therefore, do not add lubricant to motor bearings. The agitator is equipped with two ball bearings that should be lubricated periodically by a Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer (Depot). Thermal protector An internal thermal protector has been designed into your cleaner to protect it from overheating. When the thermal protector activates, the cleaner will stop running. If this happens, proceed as follows: 1. Turn the cleaner OFF and disconnect it from the electrical outlet. 2. Check secondary and final filters for dirt accumulation. 3. Refer to "Clearing blockages" section. 4. When cleaner is unplugged and the motor cools for 30 minutes, the thermal protector automatically resets and cleaning may continue. If the thermal protector continues to activate after following the above steps, your cleaner may need servicing (see "Service" section). Service To obtain approved HOOVER service and genuine HOOVER parts, locate the nearest Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer (Depot) by: • checking the Yellow Pages under "Vacuum Cleaners-Household" OR - • checking the list of Factory Service Centers provided with this cleaner OR - • checking the Service section of The Hoover Company on-line at www.hoover.com OR - • calling 1-800-944-9200 for an automated referral of authorized service outlet locations (U.S. only). Do not send your cleaner to The Hoover Company in North Canton for service, this will only result in delay. If further assistance is needed, contact The Hoover Company Consumer Response Center, North Canton, Ohio 44270, Phone: 1-330499-9499. In Canada, contact Hoover Canada, Burlington, Ontario L7R 4A8, Phone: 1-800-263-6376. Always identify your cleaner by the complete model number when requesting information or ordering parts. (The model number appears on the bottom of the cleaner.) 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

How to replace
Disconnect cleaner from electrical
outlet.
Remove bottom plate, belt and agi-
tator following directions in “The
belt” section beginning with Fig. 3-
10.
Discard old agitator.
Continue following the directions in
“The belt” section to reposition belt,
new agitator and bottom plate.
11
Replacing bottom plate
Reposition bottom plate and 4
Phillips head screws. Tighten
screws securely.
3-16
The agitator brush roll
The edge groomers
When to replace
The edge groomers, located on both
sides of the nozzle, should be
replaced when they appear worn.
What to buy
When purchasing edge groomers,
ask for
HOOVER part No.
39511004.
How to replace
Disconnect cleaner from electrical
outlet.
Remove bottom plate as described
in “The belt” section (Fig. 3-10).
Installing groomers
Lift off both old edge groomers and
slide new edge groomers into posi-
tion as shown.
Reposition bottom plate and secure
with 4 Phillips head screws.
3-17
3-15
When to replace
When agitator brushes are worn, the
agitator should be replaced.
To check condition of brushes,
dis-
connect cleaner from electrical
outlet.
Move edge of a card across bottom
plate while turning agitator.
To
maintain cleaning effectiveness,
replace agitator if brushes do not
touch card.
What to buy
Your cleaner requires either a 13” or
15” agitator. When purchasing a
new agitator, ask for one of the fol-
lowing:
13” -
HOOVER part No. 48414110
15” -
HOOVER part No. 48414115
Lubrication
The motor is equipped with bear-
ings that contain sufficient lubrica-
tion for the life of the motor. The
addition of lubricant could cause
damage.
Therefore, do not add
lubricant to motor bearings.
The
agitator is equipped with two ball
bearings that should be lubricated
periodically by a Hoover Factory
Service Center or an Authorized
Hoover Warranty Service Dealer
(Depot).
Thermal protector
An internal thermal protector has been
designed into your cleaner to protect
it from overheating.
When the thermal protector acti-
vates, the cleaner will stop running.
If this happens, proceed as follows:
1. Turn the cleaner OFF and discon-
nect it from the electrical outlet.
2. Check secondary and final filters
for dirt accumulation.
3. Refer to “Clearing blockages”
section.
4.
When cleaner is unplugged and
the motor cools for 30 minutes,
the
thermal protector automatically resets
and cleaning may continue.
If the thermal protector continues to
activate after following the above
steps, your cleaner may need servic-
ing (see “Service” section).
Service
To obtain approved HOOVER service
and genuine HOOVER parts, locate
the nearest
Hoover Factory Service
Center or Authorized Hoover
Warranty Service Dealer (Depot)
by:
• checking the Yellow Pages
under “Vacuum Cleaners-House-
hold” OR -
• checking the list of Factory
Service Centers provided with this
cleaner OR -
• checking the Service section of
The Hoover Company on-line at
www.hoover.com
OR -
• calling 1-800-944-9200 for an
automated referral of authorized ser-
vice outlet locations (U.S. only).
Do not
send your cleaner to The
Hoover Company in North Canton for
service, this will only result in delay.
If further assistance is needed, con-
tact The Hoover Company
Consumer Response Center, North
Canton, Ohio 44270,
Phone: 1-330-
499-9499.
In Canada, contact Hoover Canada,
Burlington, Ontario L7R 4A8,
Phone:
1-800-263-6376.
Always identify your cleaner by the
complete
model number when
requesting information or ordering
parts. (The model number appears
on the bottom of the cleaner.)