7 • Completing Your Installation With a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly. WARNING: Use only the light fixture supplied with this fan model. The switch housing assembly is made up of three sections: the switch housing gasket, the upper switch housing, and the lower switch housing/ light assembly. ATTACHING THE SWITCH HOUSING GASKET AND UPPER SWITCH HOUSING 7-1. Locate the switch housing mounting plate, the switch housing gasket and the upper plug connector as shown. NOTE: Your fan may come with the switch housing gasket attached to the switch housing mounting plate. If the switch housing gasket is attached to the switch housing mounting plate, go to the section "Attaching the Upper Switch Housing." If the switch housing gasket is not attached complete the steps below. 7-2. Identify the top side of the switch housing gasket by looking for the raised circular ridge on the gasket. 7-3. With the top side of the switch housing gasket facing up towards the motor, align the holes in the gasket with the spokes on the switch housing mounting plate. 7-4. Feed the upper plug connector through the center opening of the upper switch housing. Push the gasket up so that it is seated flush with the mounting plate . Gasket Step 7-1 Holes Step 7-3 Mounting Plate Upper Plug Spokes CAUTION: Make sure the upper switch housing is securely attached to the switch housing mounting plate. Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling. Upper Switch Housing Step 7-4 Upper Plug 10 42786-01 • 08/14/09 • Hunter Fan Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Your Hunter fan comes with an integrated light fixture assembly.
WARNING:
Use only the light fixture supplied with this fan model.
°e switch housing assembly is made up of three sections: the switch
housing gasket, the upper switch housing, and the lower switch housing/
light assembly.
ATTACHING THE SWITCH HOUSING GASKET
AND UPPER SWITCH HOUSING
7-1. Locate the switch housing mounting plate, the switch housing gasket
and the upper plug connector as shown.
NOTE:
Your fan may come with the switch housing gasket attached
to the switch housing mounting plate.
If the switch housing gasket is attached to the switch housing mount
-
ing plate, go to the section "Attaching the Upper Switch Housing."
If the switch housing gasket is not attached complete the steps
below.
7-2. Identify the top side of the switch housing gasket by looking for the
raised circular ridge on the gasket.
7-3. With the top side of the switch housing gasket facing up towards the
motor, align the holes in the gasket with the spokes on the switch
housing mounting plate.
7-4. Feed the upper plug connector through the center opening of the
upper switch housing.
Push the gasket up so that it is seated flush
with the mounting plate .
CAUTION:
Make sure the upper switch housing is securely
attached to the switch housing mounting plate. Failure to
properly attach and tighten all three assembly screws could
result in the switch housing and light fixture falling.
10
42786-01
08/14/09
Hunter Fan Company
7 • Completing Your Installation With a Bowl Light Fixture
Step 7-1
Step 7-3
Step 7-4
Gasket
Holes
Mounting
Plate
Spokes
Upper
Plug
Upper
Plug
Upper
Switch
Housing