IBM DTLA-307075 Hard Drive Specifications - Page 55

logical head default

Page 55 highlights

7.3.2.2 15 logical head default The positions of jumper blocks shown below is used to select Device 0, Device 1, Cable Selection, or Device 0 Forcing Device 1 Present, setting 15 logical heads instead of default 16 logical head models. IGECA HFDB DEVICE 0 (Master) IGECA HFDB DEVICE 1 (Slave) IGECA HFDB CABLE SEL IGECA HFDB DEVICE 0 FORCING DEVICE 1 PRESENT Figure 45. Jumper positions for 15 logical head default Notes: 1. To enable the CSEL mode (Cable Selection mode) the jumper block must be installed at E-F. In the CSEL mode, the drive address is determined by AT interface signal #28 CSEL as follows: Ÿ When CSEL is grounded or at a low level, the drive address is 0 (Device0). Ÿ When CSEL is open or at a high level, the drive address is 1 (Device1). 2. In CSEL mode, installing or removing the jumper blocks at A-C or B-D position does not affect any selection of Device or Cable Selection mode. Deskstar 40GV & 75GXP hard disk drive specifications 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

7.3.2.2
15 logical head default
The positions of jumper blocks shown below is used to select Device 0, Device 1, Cable Selection, or
Device 0 Forcing Device 1 Present, setting 15 logical heads instead of default 16 logical head models.
G
I
E
C
A
H
F
D
B
DEVICE 0
(Master)
G
I
E
C
A
H
F
D
B
DEVICE 1
(Slave)
G
I
E
C
A
H
F
D
B
CABLE SEL
G
I
E
C
A
H
F
D
B
DEVICE 0 FORCING
DEVICE 1 PRESENT
Figure 45. Jumper positions for 15 logical head default
Notes:
1.
To enable the CSEL mode (Cable Selection mode) the jumper block must be installed at E-F. In the
CSEL mode, the drive address is determined by AT interface signal #28 CSEL as follows:
°
When CSEL is grounded or at a low level, the drive address is 0 (Device0).
°
When CSEL is open or at a high level, the drive address is 1 (Device1).
2.
In CSEL mode, installing or removing the jumper blocks at A-C or B-D position does not affect any
selection of Device or Cable Selection mode.
Deskstar 40GV & 75GXP hard disk drive specifications
43