Icom D-STAR Instruction Manual - Page 33

Repeater Settings

Page 33 highlights

6 REPEATER SETTINGS n Frequency setting for ID-RP4000V NOTE: The repeater unit connection may not be recognized with the PC according to the using USB cable length. Use the shorter USB cable as possible is recommended. q Start up the PC. w C onnect an USB cable (A-B type; purchase sepa- rately) between PC's USB port and ID-RP4000V [SERVICE T] or [SERVICE R] connector, then turn the ID-RP4000V power ON. • Connect an USB cable to [SERVICE R] when setting receive frequency. • Connect an USB cable to [SERVICE T] when setting transmit frequency. e Start up the ID-RP4000V utility. Double click the "ID-RP4000V" icon on the desktop or select the "ID-RP4000V" in "Program" in "Start" menu. r T he screen as at left appears, then the dialog below is displayed. • Click [OK]. w Click q Enter the specified frequency. NOTE: The screen, described in steps t, appears instead of these screens when the correct COM port number is set. • Click menu then select . Enter the allocated number of the ID-RP4000V [SERVICE T/R] connector then click [Apply] in the displayed "COM Port Setting" screen. Enter the COM port number. Click N OTE: See pages 22 to 24 for the COM port number confirmation details. t T he utility reads the ID-RP4000V setting and the screen as at left appears when the correct COM port number is set. y E nter the specified receive and transmit frequencies into "RX/TX Frequency" column. u C lick [Write] to program the set frequencies into the ID-RP4000V. 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

6
30
REPEATER SETTINGS
n
Frequency setting for ID-RP4000V
NOTE:
The repeater unit connection may not be recog-
nized with the PC according to the using USB cable
length.
Use the shorter USB cable as possible is recom-
mended.
q
Start up the PC.
w
Connect an USB cable
(A-B type; purchase sepa-
rately)
between PC’s USB port and ID-RP4000V
[SERVICE T] or [SERVICE R] connector, then turn
the ID-RP4000V power ON.
• Connect an USB cable to [SERVICE R] when setting
receive frequency.
• Connect an USB cable to [SERVICE T] when setting
transmit frequency.
e
Start up the ID-RP4000V utility.
Double click the “ID-RP4000V” icon on the desktop
or select the “ID-RP4000V” in “Program” in “Start”
menu.
r
The screen as at left appears, then the dialog
below is displayed.
• Click [OK].
NOTE:
The screen, described in steps
t
, appears
instead of these screens when the correct COM
port number is set.
• Click <Option (O)> menu then select <COM Port(P)…>.
Enter the allocated number of the ID-RP4000V [SER-
VICE T/R] connector then click [Apply] in the displayed
“COM Port Setting” screen.
Enter the COM port number.
Click
NOTE:
See pages 22 to 24 for the COM port num-
ber confirmation details.
q
Enter the speci-
fied frequency.
w
Click
t
The utility reads the ID-RP4000V setting and the
screen as at left appears when the correct COM
port number is set.
y
Enter the specified receive and transmit frequen-
cies into “RX/TX Frequency” column.
u
Click [Write] to program the set frequencies into
the ID-RP4000V.