Icom ID-51A PLUS Cloning Software Instructions - Page 5

Cloning from a PC using an optional data cable - manual

Page 5 highlights

Cloning from a PC using an optional data cable To clone from a PC using an optional data cable (OPC-2218LU or OPC-2350LU), follow the steps below. Step 1 Connect the transceiver and PC using an optional data cable Step 2 Step 3 Make the initial set up Cloning (page 6) NOTE: Before reading or writing cloning data, the "DV Data TX" setting of the transceiver must be set to "PTT." Otherwise, when data is input from a PC through the [DATA] jack, the transceiver automatically transmits it. (MENU > DV Set > DV Data TX) ■■Transceiver and a PC connection using an optional data cable qqInstall the USB driver. • Download and install the latest USB driver from the Icom website. See the OPC-2218LU or the OPC-2350LU instruction manual for details. wwMake sure the transceiver power is OFF. eeConnect an optional data cable as illustrated to the right. rrPush [ ] to turn ON the transceiver. OPC-2350LU (purchase separately) to a USB port PC to [DATA] jack OPC-2218LU to a USB port (purchase separately) ■■Initial setup window Before using this software, read the instructions thoroughly, and follow the steps below to make the initial setup in order to send the version information of the transceiver to the software. NOTE: When the version information of the transceiver is not correctly sent to the software, some items may not appear on the sheets. qqClick the [COM Port] radio button. wwSelect the correct COM port number from the drop- down list, or directly enter the COM port number into the box. • S ee the "Driver Installation Guide" to check the COM port. eeClick [OK] to open the cloning screen. Click Click - 5 - A-7178-1EX © 2014 Icom Inc.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

5
A-7178-1EX
© 2014
Icom Inc.
Install the USB driver.
q
• Download and install the latest USB driver from the
Icom website.
See the OPC-2218LU or the OPC-2350LU instruction
manual for details.
Make sure the transceiver power is OFF.
w
Connect an optional data cable as illustrated to the
e
right.
Push [
r
] to turn ON the transceiver.
Transceiver and a PC connection using
an optional data cable
Cloning from a PC using an optional data cable
To clone from a PC using an optional data cable (OPC-2218LU or OPC-2350LU), follow the steps below.
Step 1
Connect the transceiver and PC using
an optional data cable
Step 2
Make the initial set up
Step 3
Cloning (page 6)
Initial setup window
Before using this software, read the instructions thor-
oughly, and follow the steps below to make the initial
setup in order to send the version information of the
transceiver to the software.
NOTE:
When the version information of the trans-
ceiver is not correctly sent to the software, some
items may not appear on the sheets.
Click the [COM Port] radio button.
q
Select the correct COM port number from the drop-
w
down list, or directly enter the COM port number
into the box.
• See the “Driver Installation Guide” to check the COM
port.
Click [OK] to open the cloning screen.
e
NOTE:
Before reading or writing cloning data, the “DV Data TX” setting of the transceiver must be set to “PTT.” Otherwise,
when data is input from a PC through the [DATA] jack, the transceiver automatically transmits it.
(MENU > DV Set >
DV Data TX
)
Click
Click
PC
to [DATA]
jack
OPC-2218LU
(purchase separately)
to a USB port
to a USB port
OPC-2350LU
(purchase separately)