Specification Host data transfer rate Maximum queue tags per drive Stripe sizes Maximum concurrent commands Support for multiple initiators Performance Flexibility Background services Cache options Intel® Integrated RAID Module SROMBSASMR 2.5 Gigabit/sec per PCI Express* lane As many as the drive can accept 8, 16, 32, 64, 128, 256, 512, or 1024 KB 255 Yes Native command queuing Drive migration, RAID level migration, Drive Roaming, Online Capacity Expansion - without reboot Rebuild, Consistency Check, Migration, OCE, and Patrol Read Write-back or Write-through; Read Ahead, Adaptive Read Ahead, Non Read Ahead; Cache I/O or Direct I/O; Disk Cache Fault Tolerance Table 4. Fault Tolerance Features Specification Self Monitoring Analysis and Reporting Technology (SMART) support Optional Battery Backup Drive Replacement Drive Rebuild Using Hot Spares Error Checking and Indication Intel® Integrated RAID Module SROMBSASMR • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and drive electronics. • Intel® RAID Smart Battery AXXRSBBU3 cache backup • Up to 72 hours of data retention • Auto detection of failure • Hot-plug • Hot-swap • Automatic at fail • Dedicated per Array • Global for any array • Auto-resume of initialization or rebuild on reboot • Parity generation and checking, automatic consistency checking • Patrol reads • Activity and fault LEDs • Multiple retries • Logs in NVRAM, event log, CIM, Smart, Intel® RAID Web Console 2 Intel® Integrated RAID Module SROMBSASMR Hardware User's Guide 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Intel® Integrated RAID Module SROMBSASMR Hardware User’s Guide
15
Fault Tolerance
Table 4.
Specification
Intel
®
Integrated RAID Module SROMBSASMR
Self Monitoring Analysis and
Reporting Technology (SMART)
support
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors, heads,
and drive electronics.
Optional Battery Backup
Intel
®
RAID Smart Battery AXXRSBBU3 cache backup
Up to 72 hours of data retention
Drive Replacement
Auto detection of failure
Hot-plug
Hot-swap
Drive Rebuild Using Hot Spares
Automatic at fail
Dedicated per Array
Global for any array
Auto-resume of initialization or rebuild on reboot
Error Checking and Indication
Parity generation and checking, automatic consistency
checking
Patrol reads
Activity and fault LEDs
Multiple retries
Logs in NVRAM, event log, CIM, Smart, Intel
®
RAID
Web Console 2
Fault Tolerance Features
Maximum queue tags per
drive
As many as the drive can accept
Stripe sizes
8, 16, 32, 64, 128, 256, 512, or 1024 KB
Maximum concurrent
commands
255
Support for multiple initiators
Yes
Performance
Native command queuing
Flexibility
Drive migration, RAID level migration, Drive Roaming, Online
Capacity Expansion - without reboot
Background services
Rebuild, Consistency Check, Migration, OCE, and Patrol Read
Cache options
Write-back or Write-through; Read Ahead, Adaptive Read
Ahead, Non Read Ahead; Cache I/O or Direct I/O; Disk Cache
Specification
Intel
®
Integrated RAID Module SROMBSASMR
Host data transfer rate
2.5 Gigabit/sec per PCI Express* lane