Intel DG41TX Product Specification - Page 28

Hardware Management Subsystem

Page 28 highlights

Intel Desktop Board DG41TX Technical Product Specification 1.12 Hardware Management Subsystem The hardware management features enable the board to be compatible with the Wired for Management (WfM) specification. The board has several hardware management features, including the following: • Fan monitoring and control • Thermal and voltage monitoring • Chassis intrusion detection 1.12.1 Hardware Monitoring and Fan Control The features of the hardware monitoring and fan control include: • SIO smart fan control, delivering acoustically-optimized thermal management • Fan speed control controllers and sensors integrated into the SIO • Three thermal sensors (processor, 82G41 GMCH, and 82801GB ICH7) • Power supply monitoring of five voltages (+5 Vsb, +5V, +12 V, +3.3 V, and +VCCP) to detect levels above or below acceptable values • Thermally monitored closed-loop fan control, for both fans, that can adjust the fan speed according to thermal conditions 1.12.2 Fan Monitoring Fan monitoring can be implemented using third-party software. The level of monitoring and control is dependent on the I/O controller used with the board. For information about The functions of the fan headers Location of the fan headers Refer to Section 1.13.2.2, page 34 Figure 6, page 29 1.12.3 Chassis Intrusion Detection The board supports a chassis security feature that detects if the chassis cover is removed. The security feature uses a mechanical switch on the chassis that attaches to the chassis intrusion header. When the chassis cover is removed, the mechanical switch is in the closed position. For information about The location of the chassis intrusion header Refer to Figure 10, page 44 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Intel Desktop Board DG41TX Technical Product Specification
28
1.12
Hardware Management Subsystem
The hardware management features enable the board to be compatible with the Wired
for Management (WfM) specification.
The board has several hardware management
features, including the following:
Fan monitoring and control
Thermal and voltage monitoring
Chassis intrusion detection
1.12.1
Hardware Monitoring and Fan Control
The features of the hardware monitoring and fan control include:
SIO smart fan control, delivering acoustically-optimized thermal management
Fan speed control controllers and sensors integrated into the SIO
Three thermal sensors (processor, 82G41 GMCH, and 82801GB ICH7)
Power supply monitoring of five voltages (+5 Vsb, +5V, +12 V, +3.3 V, and
+VCCP) to detect levels above or below acceptable values
Thermally monitored closed-loop fan control, for both fans, that can adjust the fan
speed according to thermal conditions
1.12.2
Fan Monitoring
Fan monitoring can be implemented using third-party software.
The level of
monitoring and control is dependent on the I/O controller used with the board.
For information about
Refer to
The functions of the fan headers
Section 1.13.2.2, page 34
Location of the fan headers
Figure 6, page 29
1.12.3
Chassis Intrusion Detection
The board supports a chassis security feature that detects if the chassis cover is
removed.
The security feature uses a mechanical switch on the chassis that attaches
to the chassis intrusion header.
When the chassis cover is removed, the mechanical
switch is in the closed position.
For information about
Refer to
The location of the chassis intrusion header
Figure 10, page 44