Intel RS25DB080 Hardware User Guide

Intel RS25DB080 Manual

Intel RS25DB080 manual content summary:

  • Intel RS25DB080 | Hardware User Guide - Page 1
    Intel® Integrated RAID Controller RS25DB080 Hardware User's Guide Intel Order Number: G22857-001
  • Intel RS25DB080 | Hardware User Guide - Page 2
    or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2011 by Intel Corporation. Portions Copyright 2011 by LSI Corporation. All rights reserved. ii Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 3
    guide for the Intel® RAID Controller RS25DB080, which can be used to manage SAS and SATA disk drives. It contains installation instructions and specifications. For details on configuring the storage adapters, and for an overview of the software drivers, see the Intel® RAID Software User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 4
    iv Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 5
    7 Requirements ...7 Installing the RAID Controller 7 Configuring the RAID Controller 11 Replacing a Controller ...11 Resolving a Config Mismatch 11 Chapter 3: Intel® RAID Controller RS25DB080 Characteristics 13 Major Components ...16 LSI* SAS2208 ROC ...16 Flash ROM ...16 Boot Strap ROM (SEEPROM
  • Intel RS25DB080 | Hardware User Guide - Page 6
    Migration ...32 Appendix B: Installation/Assembly Safety Instructions 33 English ...35 Deutsch ...36 Français ...37 Español ...39 Italiano ...40 Appendix C: Regulatory and Certification Information 43 Product Safety and EMC Compliance 43 vi Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 7
    the Intel® RAID Controller RS25DB080 9 Figure 3. Connecting Cable between the RAID Controller and Drives/Backplane 10 Figure 4. Card Layout...13 Figure 5. Cache Memory Board 13 Figure 6. Hardware Block Diagram 15 Figure 7. Intel® RAID Smart Battery AXXRSBBU9 17 Figure 8. Intel® RAID Controller
  • Intel RS25DB080 | Hardware User Guide - Page 8
    viii Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 9
    8. Technical Specifications 24 Table 9. Array Performance Features 25 Table 10. Fault Tolerance Features 26 Table 11. Actual Power Consumption Table 27 Table 12. RAID Physical Drive Status 29 Table 13. RAID Virtual Drive Status 30 Intel® RAID Controller RS25DB080 Hardware User's Guide ix
  • Intel RS25DB080 | Hardware User Guide - Page 10
    x Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 11
    and cable are easier to manipulate, connect to smaller devices, and do not inhibit airflow. The point-to-point SATA architecture eliminates difficulties created by the legacy ATA master-slave architecture, while maintaining compatibility with existing ATA firmware. Intel® RAID Controller RS25DB080
  • Intel RS25DB080 | Hardware User Guide - Page 12
    capable of performance up to 5 Gb/s per lane. The RAID Controller is designed to fit various Intel® Server Boards and systems. For the most up-to-date support list, see the Compatibility section under the link for this Intel® RAID Controller at http://www.intel.com/p/en_US/support/server. Protocol
  • Intel RS25DB080 | Hardware User Guide - Page 13
    RAID controller baseboard as the RAID cache. • Small, thin cabling with serial point-to-point 6.0 Gbps data transfer rates. • Support for non-disk devices and mixed capacity drives. • Support for intelligent XOR RAID levels 0, 1, 5, 6, 10 ). Intel® RAID Controller RS25DB080 Hardware User's Guide 3
  • Intel RS25DB080 | Hardware User Guide - Page 14
    the cache. ✧ Direct I/O: Reads data directly from disk. (not cache) • Redundancy through: - Configuration stored in non-volatile RAM and on the drives (COD). - Hot-swap support. - Optional battery backup for cache memory. 4 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 15
    Disable Alarm. To enable the alarm, choose Enable Alarm. To disable the alarm only until the next event or until next power cycle, choose SilenceAlarm. Intel® RAID Controller RS25DB080 Hardware User's Guide 5
  • Intel RS25DB080 | Hardware User Guide - Page 16
    6 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 17
    be ordered from Intel separately. • Compatible SAS/SATA cables (for cable requirements, see step 4 in "Installing the RAID Controller") Note: Intel Corporation strongly recommends using an uninterruptible power supply (UPS). Installing the RAID Controller To install the RAID Controller, follow these
  • Intel RS25DB080 | Hardware User Guide - Page 18
    the Bracket 4. Install the RAID controller into an available server system x8 or x16 PCI-Express* slot (see Figure 2). To locate an appropriate slot and for instructions on installing an add-in card, see your server system documentation. 8 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 19
    the Intel® RAID Controller RS25DB080 5. Connect the provided cables into the adapter using the 4-port combined end. Make sure the controller and cables are properly attached and plug the cable into connector at the inside edge of the adapter. Note: To prevent throughput problems: ✧ Use the cables
  • Intel RS25DB080 | Hardware User Guide - Page 20
    A C B Ports 0-3 Ports 4-7 D AF003885 Figure 3. Connecting Cable between the RAID Controller and Drives/Backplane 6. Install the server system cover and connect the power cords. See your server system documentation for instructions. 10 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 21
    then display the Intel® RAID Controller RS25DB080 number and firmware version. The numbering of the RAID controller follows the PCI slot scanning order used by the server board. 3. See the Quick Start User's Guide and the Software User's Guide for instructions to configure the RAID controller and to
  • Intel RS25DB080 | Hardware User Guide - Page 22
    12 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 23
    and is secured by one screw. It provides a 20-pin connector for remote battery backup module or SuperCap module installation support for base controllers that do not have a 20-pin connector on the controller. Figure 5. Cache Memory Board Intel® RAID Controller RS25DB080 Hardware User's Guide 13
  • Intel RS25DB080 | Hardware User Guide - Page 24
    Connects the controller by cable to SAS drives or SATA 2 drives. Advanced Software Hardware Key Header 3-pin header Enables support for selected advanced features, such as recovery, Supersized cache, FastPath, and full disk encryption. Standard edge card connector The RAID controller interfaces
  • Intel RS25DB080 | Hardware User Guide - Page 25
    an interface to the memory board that contains 1GB 667MHz DDR3 memory. The memory board can be connected to an optional Intel® RAID Smart Battery AXXRSBBU9. 4-pin connector Reserved for factory use. Figure 6. Hardware Block Diagram Intel® RAID Controller RS25DB080 Hardware User's Guide 15
  • Intel RS25DB080 | Hardware User Guide - Page 26
    , which integrated DDR3 667 MHz ECC SDRAM memory. This DIMM is connected directly to the memory controller interface bus of the ROC and serves as storage for the executable code transferred from the flash. It also serves as cache during 16 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 27
    -bit detection support. The Intel® RAID Controller RS25DB080 supports Intel® RAID Smart Battery AXXRSBBU9. The optional Intel® RAID Smart Battery AXXRSBBU9 provides a battery backup option for data cached in the memory. It is connected remotely to the RAID controller through a supplied cable. See
  • Intel RS25DB080 | Hardware User Guide - Page 28
    to adhere to the SFF-8485 Specifications for SGPIO support. Internal connector Figure 8. Intel® RAID Controller RS25DB080 SAS/SATA Connectors SAS/SATA Connector Pin-out serial ATA connector are not compatible with the legacy PATA connector. 18 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 29
    Table 2. SFF8087 Internal Connector with one SGPIO Connector Pin-out Controller Connector Pin-out SFF-8087 Pin # Pin Definition Backplane Connector Pin-out Pin # T A11 SB5/SDATA_IN/ADD R A8 SB7/BP_TYPE B11 SB6/CTLR_TYPE Intel® RAID Controller RS25DB080 Hardware User's Guide 19
  • Intel RS25DB080 | Hardware User Guide - Page 30
    one SGPIO Connector Note: The RAID controller in this document doesn't ship with SAS/SATA cables. Users can separately order the SAS/SATA cable accessory kit (product code - AXXCBL740MS7P), which has two SFF8087 (mini-SAS) to SATA cables. 20 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 31
    Ground I2C Clock Ground I2C Data Power Fail Ground Battery Backup Enabled Battery Backup Strobe Battery Backup Status I2C Connector Pin-Out Table 4. I2C Connector Pin-Out Pin Number 1 2 3 Description SMB_SAS_SES_SDA GND SMB_SAS_SES_SCL Intel® RAID Controller RS25DB080 Hardware User's Guide 21
  • Intel RS25DB080 | Hardware User Guide - Page 32
    Connected to GFAULT Drain of onboard MFT Connected to Drain DIRTY of onboard MFT Description 330? to P3V3_DUAL Connected to Drain of onboard MFT Figure 10. LED Header 22 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 33
    of LED for PHY 1 Cathode of LED for PHY 0 Pin# 2 4 6 8 10 12 14 16 Name FLT_LED7_PU FLT_LED6_PU FLT_LED5_PU FLT_LED4_PU FLT_LED3_PU FLT_LED2_PU FLT_LED1_PU FLT_LED0_PU Description Anode of LED for 11. Individual PHY/Drive Fault Header Intel® RAID Controller RS25DB080 Hardware User's Guide 23
  • Intel RS25DB080 | Hardware User Guide - Page 34
    voltage Card size Array interface to host SAS/SATA bus speed SAS/SATA ports Physical and virtual drive support Cache Firmware Compatible devices Intel® RAID Controller RS25DB080 LSISAS2208 Integrated ROC, 800 MHz +3.3 V, +12 V 2.713 inch x 6.600 inch (Low-profile) PCI Express* Revision 2.0, x8 lane
  • Intel RS25DB080 | Hardware User Guide - Page 35
    Yes Performance Flexibility Background services Native command queuing • Drive migration • RAID level migration • Drive Roaming • Online Capacity Expansion - without reboot • Rebuild • Consistency Check • Migration • OCE • Patrol Read Intel® RAID Controller RS25DB080 Hardware User's Guide 25
  • Intel RS25DB080 | Hardware User Guide - Page 36
    and Reporting Technology (SMART) support Optional Battery Backup Drive Replacement Drive Rebuild Using Hot Spares Error Checking and Indication Intel® RAID Controller RS25DB080 • Detects up to 70% of predictable disk drive failures • Monitors the internal performance of all motors, heads, and
  • Intel RS25DB080 | Hardware User Guide - Page 37
    on the board will be 12.96V potential difference, referenced from ground to +12V. Operating Certifications The RAID controller in this document is qualified to get Microsoft Windows* Winqual certification (WHQL) at product launch. Intel® RAID Controller RS25DB080 Hardware User's Guide 27
  • Intel RS25DB080 | Hardware User Guide - Page 38
    The various device technologies supported by the Intel® RAID Controller RS25DB080 is described in the subsections that follow. Support for Hard Disk Drive Devices The Intel® RAID Controller RS25DB080 integrates eight internal high-performance SAS/SATA III ports that support SAS and enterprise-class
  • Intel RS25DB080 | Hardware User Guide - Page 39
    on which the firmware detects an unrecoverable RAID configuration is concerned. None None A physical drive with an unsupported flag set. An Unconfigured Good or Offline physical drive that has completed the 'prepare for removal' operation. Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 40
    system and is unusable. RAID Controller Drive Limitations Only drives that comply with the SAS and SATA specification extensions are supported. SAS Bus and ID Mapping Devices on the SAS bus are persistently mapped based on a SAS address. 30 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 41
    are inserted properly. 6. Install the server cover. For instructions, see your server system documentation. 7. Plug in and power on the system. The controller detects the RAID configuration from the configuration data on the drives (COD). Intel® RAID Controller RS25DB080 Hardware User's Guide 31
  • Intel RS25DB080 | Hardware User Guide - Page 42
    cannot be supported at the instructions, see your server system documentation. 10. Plug in and power on the system. When you start the system, the controller detects the RAID configuration from the configuration data on the drives. 32 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 43
    on your computer system's cables and that the cables are not located where they service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions Intel® RAID Controller RS25DB080 Hardware User's Guide 33
  • Intel RS25DB080 | Hardware User Guide - Page 44
    keep them evenly aligned to avoid bending any connector pins. Also, before you connect a cable, make sure both connectors are correctly oriented and aligned. • Handle components and cards with , use antistatic floor pads and workbench pads. 34 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 45
    performing any of the instructions. See also Intel® Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://www.intel.com/support/motherboards all external cables and the AC power cord(s) to the system. Intel® RAID Controller RS25DB080 Hardware User's Guide 35
  • Intel RS25DB080 | Hardware User Guide - Page 46
    Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und -Servergehäusen auf der Ressourcen-CD oder unter http://www.intel.com/support/motherboards/server/sb/cs-010770.htm. System niemals ohne ordnungsgemäß montiertes Gehäuse ein. 36 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 47
    dans ce document avant de suivre toute instruction. Consultez Intel® Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http://www.intel.com/support/motherboards/server/sb/cs-010770.htm Intel® RAID Controller RS25DB080 Hardware User's Guide 37
  • Intel RS25DB080 | Hardware User Guide - Page 48
    afin de prévenir tout accès non autorisé à l'intérieur du système. 5. Rebranchez tous les cordons d'alimentation c. a. et câbles externes au système. 38 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 49
    intel.com/support/motherboards/server/sb/cs-010770.htm Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla, deberá desenchufar todos los cables las tapas. Intel® RAID Controller RS25DB080 Hardware User's Guide 39
  • Intel RS25DB080 | Hardware User Guide - Page 50
    para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. Si el sistema ha estado en funcionamiento, vicino all'unità e deve essere facilmente accessibile. 40 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 51
    dissipatore di calore potrebbero essere surriscaldati. Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio. È consigliabile l'uso di guanti di protezione. Intel® RAID Controller RS25DB080 Hardware User's Guide 41
  • Intel RS25DB080 | Hardware User Guide - Page 52
    42 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • Intel RS25DB080 | Hardware User Guide - Page 53
    for regulatory compliance as an Intel end system, and is included as part of the end system certification. For information on end system certification, refer to the product regulatory certification for the end system level product. Intel® RAID Controller RS25DB080 Hardware User's Guide 43
  • Intel RS25DB080 | Hardware User Guide - Page 54
    44 Intel® RAID Controller RS25DB080 Hardware User's Guide
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Intel
®
Integrated RAID Controller
RS25DB080 Hardware User’s Guide
Intel Order Number: G22857-001