Intel S3420GPLC Product Specification - Page 130

Sensor Type

Page 130 highlights

Appendix B: Integrated BMC Sensor Tables Intel® Server Board S3420GP TPS Sensor Name3 Fan Tach Sensors Sensor # Platform Sensor Type Applicability Event / Reading Type 30h- 34h Chassisspecific Fan Threshold 04h 01h Processor Therm Margin 62h Processor Therm Ctrl % 64h Processor VRD Temp 66h CATERR 68h PCH Thermal Trip 6Ah All Temperatur e 01h Threshold 01h All Temperatur e Threshold 01h 01h Temperatur Digital All e Discrete 01h 05h All Processor 07h Digital Discrete 03h Temperatur Digital All e Discrete 01h 03h Event Offset Triggers [l] [c,nc] - [u] [c] 01 - Limit exceeded 01 - State Asserted 01 - State Asserted Contrib. To System Status nc = Degraded c = Nonfatal2 Assert / De- assert Readable Value / Offsets As and De Analog - - Analog Event Data R, T - Rearm Standby M - - Non-fatal As and De Analog Trig Offset A - Fatal As and De - Trig Offset M - Non-fatal As and De - Trig Offset M - Fatal As and De - Trig Offset M - 118 Revision 2.4 Intel order number E65697-010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

Appendix B: Integrated BMC Sensor Tables
Intel® Server Board S3420GP TPS
Revision 2.4
Intel order number E65697-010
118
Sensor Name
3
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Fan Tach Sensors
30h–
34h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
2
As and
De
Analog
R, T
M
Processor Therm
Margin
62h
All
Temperatur
e
01h
Threshold
01h
Analog
Processor Therm Ctrl %
64h
All
Temperatur
e
01h
Threshold
01h
[u] [c]
Non-fatal
As and
De
Analog
Trig Offset
A
Processor VRD Temp
66h
All
Temperatur
e
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
Trig Offset
M
CATERR
68h
All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Non-fatal
As and
De
Trig Offset
M
PCH Thermal Trip
6Ah
All
Temperatur
e
01h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and
De
Trig Offset
M