Intel S5500HCV Service Guide - Page 26

Optional Hardware

Page 26 highlights

Server Board Features Optional Hardware Intel® SAS Entry RAID Module AXX4SASMOD The Intel® Server Board S5520HC / S5500HCV provide a SAS module slot (J2J1) for the installation of an optional Intel® SAS Entry RAID Module AXX4SASMOD. Once the optional Intel® SAS Entry RAID Module AXX4SASMOD is present, the x4 PCI Express* links from the ICH10R to PCI Express* Slot 2 (x8 mechanically, x4 electrically) switches to the SAS module slot. The optional Intel® SAS Entry RAID Module AXX4SASMOD includes a SAS1064e controller that supports x4 PCI Express* link widths and is a single-function PCI Express* end-point device. The SAS controller supports the SAS protocol as described in the Serial Attached SCSI (SAS) Standard, version 1.0, and also supports SAS 1.1 features. A 32-bit external memory bus off the SAS1064e controller provides an interface for Flash ROM and NVSRAM (Nonvolatile Static Random Access Memory) devices. The optional Intel® SAS Entry RAID Module AXX4SASMOD provides four SAS connectors that support up to four hard drives with a non-expander backplane or up to eight hard drives with an expander backplane. The optional Intel® SAS Entry RAID Module AXX4SASMOD also provides a SGPIO (Serial General Purpose Input / Output) connector and a SCSI Enclosure Services (SES) connector for backplane drive LED control. Figure 8. Intel® SAS Entry RAID Module SAS RAID Support The BIOS Setup Utility provides drive configuration options on the Advanced | Mass Storage Controller Configuration setup page for the Intel® SAS Entry RAID Module AXX4SASMOD, some of which affect the ability to configure RAID. The "Intel® SAS Entry RAID Module" option is enabled by default once the Intel® SAS Entry RAID Module AXX4SASMOD is present. When enabled, you can set the "Configure Intel® SAS Entry RAID Module" to either "LSI* Integrated RAID" or "Intel® ESRTII" mode. Intel® Server Board S5520HC and S5500HCV Service Guide 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Server Board Features
Intel® Server Board S5520HC and S5500HCV Service Guide
26
Optional Hardware
Intel
®
SAS Entry RAID Module AXX4SASMOD
The Intel
®
Server Board S5520HC / S5500HCV provide a SAS module slot (J2J1) for the installation of an optional
Intel
®
SAS Entry RAID Module AXX4SASMOD. Once the optional Intel
®
SAS Entry RAID Module AXX4SASMOD is
present, the x4 PCI Express* links from the ICH10R to PCI Express* Slot 2 (x8 mechanically, x4 electrically) switches
to the SAS module slot.
The optional Intel
®
SAS Entry RAID Module AXX4SASMOD includes a SAS1064e controller that supports x4 PCI
Express* link widths and is a single-function PCI Express* end-point device. The SAS controller supports the SAS
protocol as described in the Serial Attached SCSI (SAS) Standard, version 1.0, and also supports SAS 1.1 features. A
32-bit external memory bus off the SAS1064e controller provides an interface for Flash ROM and NVSRAM (Non-
volatile Static Random Access Memory) devices.
The optional Intel
®
SAS Entry RAID Module AXX4SASMOD provides four SAS connectors that support up to four hard
drives with a non-expander backplane or up to eight hard drives with an expander backplane.
The optional Intel
®
SAS Entry RAID Module AXX4SASMOD also provides a SGPIO (Serial General Purpose Input /
Output) connector and a SCSI Enclosure Services (SES) connector for backplane drive LED control.
Figure 8. Intel
®
SAS Entry RAID Module
SAS RAID Support
The BIOS Setup Utility provides drive configuration options on the Advanced | Mass Storage Controller Configuration
setup page for the Intel
®
SAS Entry RAID Module AXX4SASMOD, some of which affect the ability to configure RAID.
The “Intel
®
SAS Entry RAID Module” option is enabled by default once the Intel
®
SAS Entry RAID Module
AXX4SASMOD is present. When enabled, you can set the “Configure Intel
®
SAS Entry RAID Module” to either “LSI*
Integrated RAID” or “Intel
®
ESRTII” mode.