JVC DLA-RS2U Instructions - Page 48

RS-232C Communication Examples, This shows the communication examples of RS-232C.

Page 48 highlights

6 Others RS-232C Communication Examples This section shows the communication examples of RS-232C. „ Operating command Type Connection check Power (On) Power (Off) Input (COMP.) Remote Control (MENU) Gamma table (Custom) Gamma coefficient (1.8) Gamma data (R) Test pattern (Staircase) Command PC  This unit: 21 89 01 00 00 0A This unit  PC: 06 89 01 00 00 0A PC  This unit: 21 89 01 50 57 31 0A This unit  PC: 06 89 01 50 57 0A PC  This unit: 21 89 01 50 57 30 0A This unit  PC: 06 89 01 50 57 0A PC  This unit: 21 89 01 49 50 32 0A This unit  PC: 06 89 01 49 50 0A PC  This unit: 21 89 01 52 43 37 33 32 45 0A This unit  PC: 06 89 01 52 43 0A PC  This unit: 21 89 01 47 54 34 0A This unit  PC: 06 89 01 47 54 0A PC  This unit: 21 89 01 47 50 30 0A This unit  PC: 06 89 01 47 50 0A PC  This unit: 21 89 01 47 52 0A This unit  PC: 06 89 01 47 52 0A PC  This unit: 512 bytes of gamma data This unit  PC: 06 89 01 47 52 0A PC  This unit: 21 89 01 54 53 36 0A This unit  PC: 06 89 01 54 53 0A Description Checks connection When power is turned on from standby mode When power is turned off (standby mode) from power-on mode When video input is set to component When the same operation as pressing the [MENU] button on the remote control is made When switched to "Custom" When set to "1.8" When the red gamma data is set When staircase (gray) is set 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

6
48
Others
This section shows the communication examples of RS-232C.
Operating command
RS-232C Communication Examples
Type
Command
Description
Connection check
PC
This unit: 21 89 01 00 00 0A
This unit
PC: 06 89 01 00 00 0A
Checks connection
Power (On)
PC
This unit: 21 89 01 50 57 31 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned on from standby mode
Power (Off)
PC
This unit: 21 89 01 50 57 30 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned off (standby mode)
from power-on mode
Input (COMP.)
PC
This unit: 21 89 01 49 50 32 0A
This unit
PC: 06 89 01 49 50 0A
When video input is set to component
Remote Control
(MENU)
PC
This unit: 21 89 01 52 43 37 33 32 45 0A
This unit
PC: 06 89 01 52 43 0A
When the same operation as pressing the
[MENU] button on the remote control is made
Gamma table
(Custom)
PC
This unit: 21 89 01 47 54 34 0A
This unit
PC: 06 89 01 47 54 0A
When switched to “Custom”
Gamma coefficient
(1.8)
PC
This unit: 21 89 01 47 50 30 0A
This unit
PC: 06 89 01 47 50 0A
When set to “1.8”
Gamma data
(R)
PC
This unit: 21 89 01 47 52 0A
This unit
PC: 06 89 01 47 52 0A
PC
This unit: 512 bytes of gamma data
This unit
PC: 06 89 01 47 52 0A
When the red gamma data is set
Test pattern
(Staircase)
PC
This unit: 21 89 01 54 53 36 0A
This unit
PC: 06 89 01 54 53 0A
When staircase (gray) is set