Kenwood TS-590SG Operation Manual - Page 53

Memory Features, Storing Frequency Ranges

Page 53 highlights

1 Recall the desired memory channel. 2 Press [M.IN] to enter Memory Scroll mode. • To exit Memory Scroll mode, press [CLR]. 3 Select the memory channel where you would like the data copied, using the MULTI/CH control. 4 Press [M.IN]. Channel 00 ~ 99 Channel E0 ~ E9 RX frequency TX frequency Mode for RX Mode for TX Tone frequency CTCSS frequency Tone/ CTCSS ON/ OFF status Memory Name Memory Channel Lockout ON/ OFF Filter A/ B status ➡ Channel 00 ~ 99 Channel E0 ~ E9 ➡ RX frequency ➡ TX frequency ➡ Mode for RX ➡ Mode for TX ➡ Tone frequency ➡ CTCSS frequency ➡ Tone/ CTCSS ON/ OFF status ➡ Memory Name ➡ Memory Channel Lockout OFF ➡ Filter A/ B status Channel 00 ~ 99 Channel E0 ~ E9 ➡ Channel P0 ~ P9 ➡ TX/RX frequency RX frequency ➡ Start frequency ➡ End frequency Mode for RX ➡ Mode for TX/RX TX frequency ➡ -- Mode for TX ➡ -- Tone frequency ➡ Tone frequency CTCSS frequency ➡ CTCSS frequency Tone/ CTCSS/ Cross tone ON/ OFF status ➡ Tone/ CTCSS/ Cross tone ON/ OFF status Memory Name ➡ Memory Name Memory Channel Lockout ON/ OFF ➡ Memory Channel Lockout OFF Filter A/ B status ➡ Filter A/ B status Channel P0 ~ P9 ➡ Channel 00 ~ 99 TX/RX frequency ➡ RX frequency ➡ TX frequency Mode for TX/RX ➡ Mode for RX ➡ Mode for TX Start frequency ➡ -- End frequency ➡ -- Tone frequency ➡ Tone frequency CTCSS frequency ➡ CTCSS frequency Tone/ CTCSS/ Cross tone ON/ OFF status ➡ Tone/ CTCSS/ Cross tone ON/ OFF status MEMORY FEATURES 10 Channel P0 ~ P9 Memory Name Memory Channel Lockout ON/ OFF Filter A/ B status ➡ Channel 00 ~ 99 ➡ Memory Name ➡ Memory Channel Lockout OFF ➡ Filter A/ B status Channel P0 ~ P9 ➡ Channel P0 ~ P9 TX/RX frequency ➡ TX/RX frequency Start frequency ➡ Start frequency End frequency ➡ End frequency Mode for TX/RX ➡ Mode for TX/RX Tone frequency ➡ Tone frequency CTCSS frequency ➡ CTCSS frequency Tone/ CTCSS/ Cross tone ON/ OFF status ➡ Tone/ CTCSS/ Cross tone ON/ OFF status Memory Name ➡ Memory Name Memory Channel Lockout ON/ OFF ➡ Memory Channel Lockout OFF Filter A/ B status ➡ Filter A/ B status Note: After copying, the Memory Channel Lockout turns OFF. STORING FREQUENCY RANGES Memory channels P0 to P9 allow you to store frequency ranges for VFO tuning and Program Scan. Program Scan is described in the next chapter. To tune or scan frequencies within a specified range, store the start and end frequencies for that range in advance. 1 Press [A/B (A=B)] to select VFO A or VFO B. 2 Select the desired start frequency. 3 Press [M.IN] to enter Memory Scroll mode. • To exit Memory Scroll mode and abort the storage process, press [CLR]. 4 Turn the MULTI/CH control, or press Mic [UP]/ [DWN] to select a memory channel in the range of P0 to P9. 5 Press [M.IN] to store the start frequency in the memory channel. • "ENDINPUT" appears on the sub-display. 6 Turn the Tuning control or MULTI/CH control to select the end frequency. 7 Press [M.IN] to store the end frequency in the memory channel. • The previous data stored in the channel is overwritten. 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

45
MEMORY FEATURES
10
1
Recall the desired memory channel.
2
Press
[M.IN]
to enter Memory Scroll mode.
To exit Memory Scroll mode, press
[CLR]
.
3
Select the memory channel where you would
like the data copied, using the
MULTI/CH
control.
4
Press
[M.IN]
.
Channel 00 ~ 99
Channel E0 ~ E9
Channel 00 ~ 99
Channel E0 ~ E9
RX frequency
RX frequency
TX frequency
TX frequency
Mode for RX
Mode for RX
Mode for TX
Mode for TX
Tone frequency
Tone frequency
CTCSS frequency
CTCSS frequency
Tone/ CTCSS
ON/ OFF status
Tone/ CTCSS
ON/ OFF status
Memory Name
Memory Name
Memory Channel
Lockout ON/ OFF
Memory Channel
Lockout OFF
Filter A/ B status
Filter A/ B status
Channel 00 ~ 99
Channel E0 ~ E9
Channel P0 ~ P9
RX frequency
TX/RX frequency
Start frequency
End frequency
Mode for RX
Mode for TX/RX
TX frequency
––
Mode for TX
––
Tone frequency
Tone frequency
CTCSS frequency
CTCSS frequency
Tone/ CTCSS/ Cross
tone ON/ OFF status
Tone/ CTCSS/ Cross
tone ON/ OFF status
Memory Name
Memory Name
Memory Channel
Lockout ON/ OFF
Memory Channel
Lockout OFF
Filter A/ B status
Filter A/ B status
Channel P0 ~ P9
Channel 00 ~ 99
TX/RX frequency
RX frequency
TX frequency
Mode for TX/RX
Mode for RX
Mode for TX
Start frequency
––
End frequency
––
Tone frequency
Tone frequency
CTCSS frequency
CTCSS frequency
Tone/ CTCSS/ Cross
tone ON/ OFF status
Tone/ CTCSS/ Cross
tone ON/ OFF status
Channel P0 ~ P9
Channel 00 ~ 99
Memory Name
Memory Name
Memory Channel
Lockout ON/ OFF
Memory Channel
Lockout OFF
Filter A/ B status
Filter A/ B status
Channel P0 ~ P9
Channel P0 ~ P9
TX/RX frequency
TX/RX frequency
Start frequency
Start frequency
End frequency
End frequency
Mode for TX/RX
Mode for TX/RX
Tone frequency
Tone frequency
CTCSS frequency
CTCSS frequency
Tone/ CTCSS/ Cross
tone ON/ OFF status
Tone/ CTCSS/ Cross
tone ON/ OFF status
Memory Name
Memory Name
Memory Channel
Lockout ON/ OFF
Memory Channel
Lockout OFF
Filter A/ B status
Filter A/ B status
Note:
After copying, the Memory Channel Lockout turns OFF.
STORING FREQUENCY RANGES
Memory channels P0 to P9 allow you to store
frequency ranges for VFO tuning and Program Scan.
Program Scan is described in the next chapter.
To
tune or scan frequencies within a specified range,
store the start and end frequencies for that range in
advance.
1
Press
[A/B (A=B)]
to select VFO A or VFO B.
2
Select the desired start frequency.
3
Press
[M.IN]
to enter Memory Scroll mode.
To exit Memory Scroll mode and abort the
storage process, press
[CLR]
.
4
Turn the
MULTI/CH
control, or press Mic
[UP]
/
[DWN]
to select a memory channel in the range of
P0 to P9.
5
Press
[M.IN]
to store the start frequency in the
memory channel.
“ENDINPUT” appears on the sub-display.
6
Turn the
Tuning
control or
MULTI/CH
control to
select the end frequency.
7
Press
[M.IN]
to store the end frequency in the
memory channel.
The previous data stored in the channel is
overwritten.