LG 50PM10 Owners Manual - Page 34

Send IR Code Command: m c

Page 34 highlights

External Control Device Setup 26. ISM Method (Command2:p) G To avoid having a fixed image remain on screen. Transmission [j][p][ ][Set ID][ ][Data][Cr] Data 0: Normal 1: White wash Acknowledgement 2: Orbiter 3: Inversion [p][ ][Set ID][ ][OK][Data][x] 27. Low Power (Command2:q) G To control the low power function on/off. Transmission [j][q][ ][Set ID][ ][Data][Cr] Data 0: Low power off 1: Low power on Acknowledgement [q][ ][Set ID][ ][OK][Data][x] 28. Orbiter Time Setting (Command2:r) G To adjust orbiter operation time term. Transmission [j][r][ ][Set ID][ ][Data][Cr] Data Min: 1 ~ Max: FE Acknowledgement [r][ ][Set ID][ ][OK][Data][x] 29. Orbiter Pixel Setting (Command2:s) G To adjust pixel number in orbiter function. Transmission [j][s][ ][Set ID][ ][Data][Cr] Data Min: 1 ~ Max: 9 Acknowledgement [s][ ][Set ID][ ][OK][Data][x] 30. Picture Size Setting for Double Window mode (Command2:t) G To adjust main window size in Double Window mode. Transmission [j][t][ ][Set ID][ ][Data][Cr] Data Min: 0 ~ Max: 14 Acknowledgement [t][ ][Set ID][ ][OK][Data][x] 31. Auto Configure (Command2:u) G To adjust picture position and minimize image shaking automatically. It works only in RGB (PC) mode. Transmission [j][u][ ][Set ID][ ][Data][Cr] Data 1: To set Acknowledgement [u][ ][Set ID][ ][OK][Data][x] 32. Send IR Code (Command: m c) G To send IR remote key code Transmission [m][c][ ][Set ID][ ][Data][Cr] Data Key code: Refer to page 36. Acknowledgement [c][ ][Set ID][ ][OK][Data][x] 34 Plasma Monitor

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

34
Plasma Monitor
External Control Device Setup
26. ISM Method (Command2:p)
G
To avoid having a fixed image remain on screen.
T
ransmission
Data
0: Normal
1: White wash
2: Orbiter
3: Inversion
[j][p][
][Set ID][
][Data][Cr]
Acknowledgement
[p][
][Set ID][
][OK][Data][x]
27. Low Power (Command2:q)
G
To control the low power function on/off.
T
ransmission
Data
0: Low power off
1: Low power on
[j][q][
][Set ID][
][Data][Cr]
Acknowledgement
[q][
][Set ID][
][OK][Data][x]
28. Orbiter Time Setting (Command2:r)
G
To adjust orbiter operation time term.
T
ransmission
Data
Min: 1 ~ Max: FE
[j][r][
][Set ID][
][Data][Cr]
Acknowledgement
[r][
][Set ID][
][OK][Data][x]
29. Orbiter Pixel Setting (Command2:s)
G
To adjust pixel number in orbiter function.
T
ransmission
Data
Min: 1 ~ Max: 9
[j][s][
][Set ID][
][Data][Cr]
Acknowledgement
[s][
][Set ID][
][OK][Data][x]
30. Picture Size Setting for Double Window
mode (Command2:t)
G
To adjust main window size in Double Window mode.
T
ransmission
Data
Min: 0 ~ Max: 14
[j][t][
][Set ID][
][Data][Cr]
Acknowledgement
[t][
][Set ID][
][OK][Data][x]
31. Auto Configure (Command2:u)
G
To adjust picture position and minimize image shaking
automatically. It works only in RGB (PC) mode.
T
ransmission
Data
1: To set
[j][u][
][Set ID][
][Data][Cr]
Acknowledgement
[u][
][Set ID][
][OK][Data][x]
32. Send IR Code (Command: m c)
G
To send IR remote key code
T
ransmission
Data
Key code: Refer to page 36.
[m][c][
][Set ID][
][Data][Cr]
[c][
][Set ID][
][OK][Data][x]
Acknowledgement