Installation With Optional Pedestal Base Or Stacking Kit - dimensions
UPC - 048231011358
View all LG DLE2350W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
ENGLISH INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT WARNING : If you are installing your dryer using an optional pedestal base or stacking kit, please refer to Optional Accessories in this manual or to the instructions for your pedestal or stacking kit before proceeding with the installation. Recommended installation spacing for cabinet installation For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required. 7"* (17.8 cm) 7"* (17.8 cm) *Required spacing **For side or bottom venting, 2 inches (5.1 cm) spacing is allowed. 9"** (22.9 cm) 5"** 30" 1"** 1" 27" 1" (12.7 cm) (76.1cm) (2.5 cm) (2.5 cm)(68.6 cm) (2.5 cm) Closet ventilation requirements Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 cm2) must be installed no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm2) must be installed no more than one foot above the floor. One example shown uses vent grilles in the door. Recommended installation spacing for recessed or closet installation, with stacked washer and dryer The dimensions shown are for the recommended spacing. 771/2" (196.8 cm) *Required spacing **For side or bottom venting, 2 inches (5.1 cm) spacing is allowed. 1"* (2.5 cm) 5 1/2"** (14 cm) 11