MAINTENANCE 35 ENGLISH Performance Data Sheet Models Number 5231JA2002A-S Use with replacement cartridge 5231JA2002A This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42. System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Nominal Particulate Class III. Capacity: 500 gal (1,892 L) Substance Average Influent Concentration Influent Challenge Concentration. Units apply to each row Average Product Water Concentration Average % Reduction NSF % reduction req. or Max. permissible product water concentration Nominal Particulate Class I Particle size: >0.5 to < 1 um 24,333 At least 10,000 particles/ml 915 96 ≥ 85% Chlorine taste and odor Class III 1.9 2.0 mg/L ± 10% 0.07 96.4 ≥ 50% Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Application Guidelines/Water Supply Parameters Service Flow 0.5 gpm (1.89 lpm) Water Pressure 20 -125 psi (138 - 862 kPa) Water Temperature 36 °F - 100 °F (0.6 °C - 37.8 °C) WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines. Warranty: See Warranty Card for Details. For a replacement cartridge or for service contact your local dealer. You can also visit our website; www.lg.com or call 1-877-714-7486. CAUTION To reduce the risk of property damage due to water leakage: • Read and follow. Use instructions before installation and use of this system. • Install on COLD water lines only. • Comply with all state and local plumbing codes. • Install a pressure limiting device and water hammer arrester for inlet water pressures exceeding 80 psi (552 kPa). Refer to Uniform Plumbing Code, Sections 608.2 and 609.10). • Never install or operate where inlet water pressure may exceed 125 psi (862 kPa). • Protect filter from freezing. Remove filter in temperatures below 33°F (0.6°C). • Replace cartridge at specified service interval. Cartridge MUST be replaced at least every 12 months. Manufactured for LG® Electronics by: CUNO Incorporateda 3M Company 400 Research Parkway Meriden, CT 06450 U.S.A. Telephone: 203-237-5541 Fax: 203-238-8701

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

ENGLISH
35
MAINTENANCE
Substance
Average
Influent
Concentration
Influent Challenge
Concentration. Units apply to each
row
Average Product
Water
Concentration
Average %
Reduction
NSF % reduction req. or
Max. permissible product
water concentration
Nominal Particulate Class I
Particle size:
>0.5 to < 1 um
24,333
At least 10,000 particles/ml
915
96
85%
Chlorine taste and odor
Class III
1.9
2.0 mg/L
±
10%
0.07
96.4
50%
Capacity:
500 gal (1,892 L)
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Performance Data Sheet
Models Number 5231JA2002A-S
Use with replacement cartridge 5231JA2002A
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system as specified in NSF/ANSI 42.
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine
Taste and Odor and Nominal Particulate Class III.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.89 lpm)
Water Pressure
20 -125 psi (138 – 862 kPa)
Water Temperature
36 °F - 100 °F (0.6 °C - 37.8 °C)
CAUTION
To reduce the risk of property damage due to water
leakage:
Read and follow.
Use instructions before installation and
use of this system.
Install on COLD water lines only.
Comply with all state and local plumbing codes.
Install a pressure limiting device and water hammer
arrester for inlet water pressures exceeding 80 psi (552
kPa). Refer to Uniform Plumbing Code, Sections 608.2 and
609.10).
Never install or operate where inlet water pressure may
exceed 125 psi (862 kPa).
Protect filter from freezing. Remove filter in temperatures
below 33°F (0.6°C).
Replace cartridge at specified service interval. Cartridge
MUST be replaced at least every 12 months.
Manufactured for LG® Electronics by:
CUNO Incorporateda 3M Company 400 Research Parkway
Meriden, CT 06450 U.S.A.
Telephone: 203-237-5541
Fax: 203-238-8701
For a replacement cartridge or for service
contact your local dealer.
You can also visit our website;
www.lg.com
or call
1-877-714-7486
.
WARNING
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system.
Systems must be installed and operated in accordance with
manufacturer's recommended procedures and guidelines.
Warranty: See Warranty Card for Details.