LG LP155HED1 Owner's Manual - Page 11

Installation

Page 11 highlights

ENGLISH Installation Installation How to Install the Unit • There are sharp edges that can cause serious cuts. • When lifting the air conditioner, it is HEAVY. Use 2 people to lift. Dimension of air conditioner 1,066 mm (42") For existing sleeve, you should measure the wall sleeve dimensions. You can install the new air conditioner according to these installation instructions to achieve the best performence. All wall sleeves used to mount the new air conditioner must be in good structural condition and have the rear grille that securely attaches to the sleeve or the flange of the sleeve to secure the new air conditioner. 406 mm (16") 318 mm (12 1/2") 505 mm (20") • To avoid vibration and noise, make sure the unit is installed securely and firmly. Dimension of sleeve assembly (optional) When installing the sleeve, make certain there is nothing within 20" of the back that would interfere with heat radiation and exhaust air flow. 1066 mm (42") 406 mm (16") 349 1/4mm (13 3/4") NOTICE To maintain the best performance of the LG PTAC, INSULATION an insulation strip must be COOLED AIR attached. The insulation strip is provided with the box. INTAKE AIR Refer to the diagram below. 1/4" Bubble of the level 1) Take out the insulation strip from the upper packing. WALL WALL SLEEVE HEAT RADIATION Over 20" 2) Attach the insulation strip onto the rear upper side of the wall sleeve. 3) If anyone would like to improve unit energy efficiency, it is recommended the change of outside grille for an unit protection and an addition of a plastic rear grille. (This is optional.) 280 mm (11") Front Insulation Strip Sleeve Rear Owner's Manual 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

Owner’s Manual
11
ENGLISH
Installation
How to Install the Unit
Installation
406 mm
(16")
406 mm
(16")
1,066 mm
(42")
1066 mm
(42")
318 mm
(12
1
/
2
")
349
1
/
4
mm
(13
3
/
4
")
505 mm
(20")
Over 20"
HEAT
RADIATION
WALL
WALL
INSULATION
SLEEVE
INTAKE
AIR
COOLED
AIR
1/4" Bubble
of the level
Front
Insulation Strip
Rear
Sleeve
280 mm
(11")
• There are sharp edges that can cause serious cuts.
• When lifting the air conditioner, it is HEAVY.
Use 2 people to lift.
For existing sleeve,
you should measure the wall
sleeve dimensions.
You can install the new air conditioner according to
these installation instructions to achieve the best
performence. All wall sleeves used to mount the new air
conditioner must be in good structural condition and
have the rear grille that securely attaches to the sleeve
or the flange of the sleeve to secure the new air
conditioner.
• To avoid vibration and noise, make sure the unit is
installed securely and firmly.
When installing the sleeve, make certain there is
nothing within 20" of the back that would interfere with
heat radiation and exhaust air flow.
To maintain the best
performance of the LG PTAC,
an insulation strip must be
attached. The insulation strip
is provided with the box.
Refer to the diagram below.
1) Take out the insulation strip from the upper packing.
2) Attach the insulation strip onto the rear upper side of
the wall sleeve.
3) If anyone would like to improve unit energy efficiency,
it is recommended the change of outside grille for an
unit protection and an addition of a plastic rear grille.
(This is optional.)
NOTICE
Dimension of air conditioner
Dimension of sleeve assembly (optional)