LG LWHD1000R Service Manual - Page 11
Service Manual, Installation - air conditioner
View all LG LWHD1000R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
4. SECURE THE GUIDE PANELS Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Figure. 11. 5. INSTALL THE SASH SEAL AND SASH LOCK a. Cut the sash seal (TYPE E) to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room, as shown in Figure. 11. b. Fasten the L bracket using a (TYPE A) screw, as shown in Figure. 11. 6. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. NOTICE REMOVAL FROM WINDOW Trun the air conditioner off, disconnect the power cord, remove the L bracket and the screws installed through the top and bottom of the guide panels, and save for reinstallation later. Close the guide panels. keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air conditioner backward, draining any condensate water. Lift the air conditioner from the window ad remove the sash seal from between the windows. L Bracket Type A Type B Figure 11 Installation Sash Seal (Type F) Service Manual 11