Troubleshooting Guide Possible Trouble 4 FAN does not operate. Is the voltage NO.1 or 2 or 4 NO of IC01M DC 12V? YES Is the voltage NO.16 or 15 or 13 NO of IC01M 0V? YES • Check the RY-Hi or RY-Med or RY-Lo. • Check the wiring diagram. • Replace IC01M. • Replace IC01M. Possible Trouble 5 The function of Energy Saver does not operate. Is the mode NO key pushed once more from cool mode? YES Is the voltage No.3 of NO CN-AC/DC of AC PCB Ass'y DC 5V? YES • Reference to OWNER'S MANUAL. • Set the mode key to Energy Saver mode. • Check the Energy Saver mode key. • Check the pattern of AC & DC PCB. 28 Room Air Conditioner

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

28
Room Air Conditioner
Troubleshooting Guide
Possible Trouble
4
FAN does not operate.
Possible Trouble 5
The function of Energy Saver does not operate.
• Replace IC01M.
• Replace IC01M.
Is the voltage NO.1 or 2 or 4
of IC01M DC 12V?
Is the voltage NO.16 or 15 or 13
of IC01M 0V?
• Check the RY-Hi or
RY-Med or RY-Lo.
Check the wiring diagram.
NO
NO
YES
YES
NO
NO
YES
YES
Is the mode
key pushed once more from
cool mode?
Is the voltage No.3 of
CN-AC/DC of AC PCB
Ass'y DC 5V?
• Reference to
OWNER'S MANUAL.
• Set the mode key to
Energy Saver mode.
• Check the Energy
Saver mode key.
• Check the pattern of
AC & DC PCB.