POST Error Code FRU/Action 604 And able to run diagnostics 1. Run Setup and verify diskette configuration settings 2. Diskette Drive A/B 3. Diskette Drive Cable 4. System Board 5. Riser card 605 POST cannot unlock the diskette drive 1. Diskette Drive 2. Diskette Drive Cable 3. System Board 4. Riser card 662 1. Diskette drive configuration error or wrong diskette drive type. Run Setup Configuration 6XX Not listed above 1. Diskette Drive 2. System Board 3. Riser card 4. External Drive Adapter 5. Diskette Drive Cable 6. Power Supply 762 Math coprocessor configuration error 1. Run Setup 2. Processor 3. System Board 7XX Not listed above 1. Processor 2. System Board 962 Parallel port configuration error 1. Run Configuration 2. Parallel Adapter (if installed) 3. System Board 9XX 1. Printer 2. System Board 1047 1. 16-Bit AT™ Fast SCSI Adapter 107X Check SCSI terminator installation 1. Check SCSI terminator installation 2. SCSI Cable 3. SCSI Terminator 4. SCSI Device 5. SCSI Adapter 1101 1. Run diagnostics Serial connector error, possible system board failure 1101, 1102, 1106, 1108, 1109 1. System Board 2. Any Serial Device 1107 1. Communications Cable 2. System Board Chapter 6. Symptom-to-FRU Index 63