Table 4-11, PostScript Emulation Device Parameters
UPC - 734646313247
View all Lexmark 21Z0294 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 258 highlights
4-72 PostScript Table 4-11: PostScript Emulation Device Parameters Key Type Definition Device Parameters for the Communication Device %Parallel%, %ParallelA%, %ParallelB%, %ParallelC%, %ParallelD% (%Parallel_NV% and %Parallel_Pending% contain the same parameters) DelayedOutputClose Boolean Selects how the printer manages the port at the end of each print job. Supported values are: True False An end-of-file message is not sent until the current job and all preceding jobs finish printing. An end-of-file message is sent as soon as a job finishes executing in the interpreter, whether or not that job has finished printing. This value is set independently for each port. Enabled Boolean (Read-only) Supported values are: True False Filtering name Indicates if the input needs further filtering before the data can be correctly processed. Supported values are: InterpreterBased None Handshake integer (Read-only) Always returns a value of 2. HasNames Boolean (Read-only) Always returns False. Interpreter name (Read-only) Supported values are: PostScript AutoSelect PCL PPDS On Boolean Designates if the communication channel is On and able to receive and send data. Supported values are: True False Data is sent and processed Data is lost OutputDevice string (Read-only) PCLSmartSwitch Boolean Supported values are: True False PCL SmartSwitch is set to On. PCL SmartSwitch is set to Off. For more information, see "Using SmartSwitch" on page 2-1.