LiftMaster HDSL24UL Installation Manual - English - Page 48

Wire the Solar Panels and Batteries, Set the WALL XFMR/SOLAR switch to SOLAR.

Page 48 highlights

SOLAR PANELS Wire the Solar Panels and Batteries 24W min. - 60W max. for solar applications. NOTE: 33AH batteries are strongly recommended for optimal solar performance. 1. Connect (+) wire from solar panels to (+) pin on CHARGE IN connector on control board. 2. Connect (-) wire from solar panels to (-) pin on CHARGE IN connector on Control board. 3. Set the WALL XFMR/SOLAR switch to SOLAR. Red Wire Jumper Black Wire Red Wire Jumper Black Wire Red wire from battery harness 33AH, HD Gates K41-0102-000 33AH Batteries Black wire from battery harness 33AH, HD Gates K41-0102-000 7AH Batteries Set Switch to SOLAR Battery Wiring Control Board 20W APPLICATION IN SERIES 40W APPLICATION IN SERIES 60W APPLICATION IN SERIES 10W 10W 10W 10W 20W 20W 10W 10W 20W 20W 10W 10W 48 10W 10W 10W 10W 10W 10W

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

48
Wire the Solar Panels and Batteries
24W min. - 60W max. for solar applications.
NOTE:
33AH batteries are strongly recommended for optimal solar
performance.
1.
Connect (+) wire from solar panels to (+) pin on CHARGE IN
connector on control board.
2.
Connect (-) wire from solar panels to (-) pin on CHARGE IN
connector on Control board.
3.
Set the WALL XFMR/SOLAR switch to SOLAR.
10W
10W
10W
10W
40W APPLICATION IN SERIES
10W
10W
10W
10W
20W
20W
60W APPLICATION IN SERIES
10W
10W
10W
10W
10W
10W
20W
20W
Red Wire
Black Wire
Jumper
7AH Batteries
20W APPLICATION IN SERIES
Battery Wiring
33AH Batteries
Red Wire
Black Wire
Jumper
Black wire
from battery
harness 33AH,
HD Gates
K41-0102-000
Red wire from
battery harness
33AH, HD Gates
K41-0102-000
Set Switch to SOLAR
Control Board