ENGLISH (Original instructions) SPECIFICATIONS Model: XDT12 Fastening capacities Machine screw 4 mm - 8 mm (5/32" - 5/16") Standard bolt 5 mm - 16 mm (3/16" - 5/8") High tensile bolt 5 mm - 14 mm (3/16" - 9/16") No load speed (RPM) Max impact mode 0 - 3,600 /min Hard impact mode 0 - 3,200 /min Medium impact mode 0 - 2,100 /min Soft impact mode 0 - 1,100 /min T mode 0 - 3,600 /min Impacts per minute Max impact mode 0 - 3,800 /min Hard impact mode 0 - 3,600 /min Medium impact mode 0 - 2,600 /min Soft impact mode 0 - 1,100 /min T mode 0 - 2,600 /min Rated voltage D.C. 18 V Standard battery cartridge BL1815N, BL1820B BL1830, BL1830B, BL1840B, BL1850B, BL1860B Overall length 117 mm (4-5/8″) Net weight 1.2 kg (2.7 lbs) 1.5 kg (3.3 lbs) • Due to our continuing program of research and development, the specifications herein are subject to change without notice. • Specifications and battery cartridge may differ from country to country. • Weight, with battery cartridge, according to EPTA-Procedure 01/2003 SAFETY WARNINGS General power tool safety warnings WARNING: Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool. Work area safety 1. Keep work area clean and well lit. Cluttered or dark areas invite accidents. 2. Do not operate power tools in explosive atmo- spheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes. 3. Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control. Electrical Safety 1. Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock. 2. Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded. 3. Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock. 4. Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. 5. When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock. 6. If operating a power tool in a damp location is unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock. 2 ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

2
ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model:
XDT12
Fastening capacities
Machine screw
4 mm - 8 mm (5/32" - 5/16")
Standard bolt
5 mm - 16 mm (3/16" - 5/8")
High tensile bolt
5 mm - 14 mm (3/16" - 9/16")
No load speed (RPM)
Max impact mode
0 - 3,600 /min
Hard impact mode
0 - 3,200 /min
Medium impact mode
0 - 2,100 /min
Soft impact mode
0 - 1,100 /min
T mode
0 - 3,600 /min
Impacts per minute
Max impact mode
0 - 3,800 /min
Hard impact mode
0 - 3,600 /min
Medium impact mode
0 - 2,600 /min
Soft impact mode
0 - 1,100 /min
T mode
0 - 2,600 /min
Rated voltage
D.C. 18 V
Standard battery cartridge
BL1815N, BL1820B
BL1830, BL1830B, BL1840B,
BL1850B, BL1860B
Overall length
117 mm (4-5/8″)
Net weight
1.2 kg (2.7 lbs)
1.5 kg (3.3 lbs)
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
Specifications and battery cartridge may differ from country to country.
Weight, with battery cartridge, according to EPTA-Procedure 01/2003
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings and
all instructions.
Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1.
Keep work area clean and well lit.
Cluttered or
dark areas invite accidents.
2.
Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust.
Power tools create sparks
which may ignite the dust or fumes.
3.
Keep children and bystanders away while
operating a power tool.
Distractions can cause
you to lose control.
Electrical Safety
1.
Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools.
Unmodified plugs and matching outlets will
reduce risk of electric shock.
2.
Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators.
There is an increased risk of elec-
tric shock if your body is earthed or grounded.
3.
Do not expose power tools to rain or wet con-
ditions.
Water entering a power tool will increase
the risk of electric shock.
4.
Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts.
Damaged or entangled cords
increase the risk of electric shock.
5.
When operating a power tool outdoors, use an
extension cord suitable for outdoor use.
Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
6.
If operating a power tool in a damp location is
unavoidable, use a ground fault circuit inter-
rupter (GFCI) protected supply.
Use of a GFCI