Maytag MGD3100DW Installation Guide - Page 13
Turn on cold water faucet
View all Maytag MGD3100DW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach "Y" connector to male end of the 2 ft (0.6 m) inlet hose. Screw on coupling by hand until it is seated on connector. 3. Tighten couplings Remove protective cap from water inlet valve. Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. Using pliers, tighten the couplings with additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. 6. Turn on cold water faucet 4. A ttach long hose to "Y" connector and tighten couplings Check that the water faucets are turned on. 7. Check for leaks Attach one of the 5 ft (1.5 m) inlet hose ends to the "Y" connector. Attach washer cold inlet hose to other side of "Y" connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result. Check for leaks around "Y" connector, faucet, and hoses. 13