Grounding Instructions, Save These Instructions

Page 3 highlights

Installation Dimensions NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See the "Electrical Requirements" section. A B Electrical Requirements WARNING 30" (76.2 cm) minimum 30" (76.2 cm) typical* 66" (167.6 cm) minimum 12" (30.5 cm) minimum 14" (35.6 cm) maximum upper cabinet and side cabinet depth Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. A. 2" x 4" (5.1 x 10.2 cm) wall stud B. Grounded 3 prong outlet *30" (76.2 cm) is typical for 66" (167.6 cm) installation height. Exact dimensions may vary depending on type of range/cooktop below. NOTE: To ensure good performance, do not obstruct top vent airflow. If cabinets are deeper than 14" (35.6 cm) but no more than 15" (38.1 cm), use the bump out mounting kit replacing the I bar mounting plate from the wall. The bump out mounting kit (part # W11185746) is not provided but can be purchased from Whirlpool. 12" DEEPER 14" 14" DEEPER 15" I bar mounting plate Bump out mounting bracket Product Dimensions Observe all governing codes and ordinances. Required: ■ A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply with a fuse or circuit breaker Recommended: ■ A time-delay fuse or time-delay circuit breaker ■ A separate circuit serving only this microwave oven GROUNDING INSTRUCTIONS For all cord connected appliances: The microwave oven must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. The microwave oven is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING: Improper use of the grounding plug can result in a risk of electric shock. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the microwave oven is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician or serviceman install an outlet near the microwave oven. SAVE THESE INSTRUCTIONS 17¹⁄₈" (43.5 cm) +/- 3/16" (0.5 cm) 16¹⁄₄" (41.3 cm) (43.U127pc"mto)* 29⁷⁄₈" (76.0 cm) *Overall depth of product will vary slightly depending on door design. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
Installation Dimensions
NOTE:
The grounded 3 prong outlet must be inside the upper
cabinet. See the “Electrical Requirements” section.
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.
Exact dimensions may vary depending on type of range/cooktop
below.
NOTE:
To ensure good performance, do not obstruct top vent
airflow. If cabinets are deeper than 14" (35.6 cm) but no more
than 15" (38.1 cm), use the bump out mounting kit replacing the
I bar mounting plate from the wall. The bump out mounting kit
(part # W11185746) is not provided but can be purchased from
Whirlpool.
Product Dimensions
*Overall depth of product will vary slightly depending on door
design.
Electrical Requirements
Observe all governing codes and ordinances.
Required:
A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply with a
fuse or circuit breaker
Recommended:
A time-delay fuse or time-delay circuit breaker
A separate circuit serving only this microwave oven
A. 2" x 4" (5.1 x 10.2 cm) wall stud
B. Grounded 3 prong outlet
12" (30.5 cm) minimum
14" (35.6 cm) maximum
30"
(76.2 cm)
minimum
A
B
upper cabinet and
side cabinet depth
30"
(76.2 cm)
typical*
66" (167.6 cm) minimum
I bar mounting plate
Bump out mounting bracket
12"
DEEPER
14"
14"
DEEPER
15"
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING:
Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
16
¹⁄₄
"
(41.3 cm)
17
¹⁄₈
"
(43.5 cm)
+/-
3/16
(0.5 cm)
17"
Up to
(43.2 cm)*
cm)
29
⁷⁄₈
" (76.0
"